Entry  Sun Jun 22 22:29:04 2025, Carsten, Accelerator, Backup copy of present accelerator settings - don't use if you don't know what you are doing 
# Version: 1.3
# Comment: ParamModi Export at 2025-06-22T22:28:05.633712878+02:00[Europe/Berlin]
# Context: ESR_25_12_THORIUM_20June_v3.C1
Entry  Sun Jun 22 21:36:48 2025, Carsten, Finn, Zac, Esther, Runs, First laser scans 

[B] Scan parameters:[/B]
[TABLE border="1"]
Entry  Sun Jun 22 18:47:23 2025, Carsten, Peter, Marek, Simon, DAQ, PMT and particle detector settings 
Final voltages and thresholds for the PMTs and particle detectors before the first scan:

[TABLE border="1"]
Entry  Sun Jun 22 11:31:59 2025, Arya, Carsten, Julien, Konstantin, General, Summary morning shift 
1. UNILAC running again, so we resumed the beam tuning wherre we stopped yesterday at 14:00

2. Goals: Reduce intensity and lifetime of "antibunch" contamination while maximising intensity for main bunch/on PD
Entry  Sat Jun 21 22:33:04 2025, Peter , Danyal, Detectors, PMTs are switched off 
We have switched off all 3 PMTs  !
Entry  Sat Jun 21 21:55:18 2025, Peter, Danyal, Marek, Detectors, PMT rates no_rings_under_PMT_north.png2_rings_under_PMT_north.png
We have made two foam rings (outer diameter ca. 70 mm with a thickness of 10 mm each and placed them successively underneath PMT north. 

ring 1: ID = 55 mm 
Entry  Sat Jun 21 18:00:49 2025, Carsten, Peter, Danyal, Kristian, Marek , Detectors, PMT signals Panel4.gif
Carsten and Kristian changed (18:00) the thresholds of PMT north and PMT middle in the ESR cave. 
See picture below. The effect is negligible. 
Entry  Sat Jun 21 17:00:10 2025, Carsten, Peter, Danyal, Kristian, Marek, Detectors, PMT north exchanged Panel4.pngPanel4.jpg
We noted that the dark countrate of PMT north is about 20x higher than that of PMT middle. 

We went into the ESR cave to look for stray light. 
Entry  Sat Jun 21 11:42:50 2025, Arya, Julien, Wilfried, General, Test laser scan 
Test scan to see whether laser spot is moving while scanning

Aborted accumulation because SIS stopped. 12.9k counts
Entry  Sat Jun 21 08:48:16 2025, Arya, Julien, Wilfried, Accelerator, Low 229Th particle numbers and 229Th lifetime in ring Bildschirmfoto_timing_full_2025-06-21_09-30-46.pngBildschirmfoto_timing_end_of_manipulation_2025-06-21_09-36-24.pngBildschirmfoto_timing_full_60_2025-06-21_11-25-51.pngBildschirmfoto_PDSouth_lifetimes_2025-06-21_11-26-43.png
With reference to entry 37 Laser timing:

- at last 30 injections accumulation: 10k counts on particle detector (accumulated during manipulation until it saturates, e.g. no more Th in ESR)
Entry  Sat Jun 21 07:28:35 2025, Arya, Julien, Wilfried, Laser, Laser Timing Bildschirmfoto_IonBunch_PDs_2025-06-21.pngBildschirmfoto_rough_timing_2025-06-21_07-22-59.pngBildschirmfoto_timingcorrected_2025-06-21_08-21-53.pngBildschirmfoto_timing_final_2025-06-21_08-46-18.png
We roughly adjusted the timing based on attachment 1, for ions to be in center of electron cooler (east arc), corrected for PMTs being 2.5m closer to the
north on the west arc
then did a new 30 injection accumulation (10.8k counts on particle detector) and readjusted the timing to fine tune this
Entry  Sat Jun 21 03:13:02 2025, Alex, Anton, Rodolfo, Hiroshi, Detectors, Part Det South Bildschirmfoto_PartDetSouth_2025-06-21.png
Bunch signal on Particle Detector South. On the 

[LIST]
Entry  Sat Jun 21 03:06:19 2025, Rodolfo, Alex, Hiroshi, Anton, Laser, beam overlap with t-scrapers 2025-06-21_05-14-39-706.png2025-06-21_05-22-21-447.png2025-06-21_05-27-59-895.png2025-06-21_05-31-37-019.pngMRC-settings_Th-Beam_2025-06-21.JPG
[TABLE border="1"]
motor|ion beam position (mm) from outside|ion beam position (mm) from inside
|-
Entry  Sat Jun 21 02:32:24 2025, Alex, Anton, Rodolfo, Hiroshi, Carsten, Laser, Laser scanning setting 
This is the initial scanning range
[LIST]
[*] 3 Loops
Entry  Sat Jun 21 01:40:31 2025, Carsten, Alex, Anton, Rodolfo, Hiroshi, Accelerator, beam parameters 
The revolution frequency for the measurement condition is: 1.542728 MHz.
The electron cooler voltage is: 104411 V.
Entry  Sat Jun 21 00:52:07 2025, Carsten, Accelerator, Summary of the last days (bunches wiht several isotopes still in ) / frequency of the  
Initially, we has very low SIS beam intensities in the 1e8 region. Setting up ESR wiht Stacking etc. turned out to be extremly tedious for the ESR crew.
Yet, they managed to get stochastic ooling working early on.
Entry  Sat Jun 21 00:23:22 2025, Rodolfo, Laser, Dye Farbstoff_FL27.jpg
I have prepared new (fresh) dye solutions of Fluorescein 27: 2 charges. They are in the Safety Cabinet (Sicherheitsschrank) in the ESR Laser lab
Entry  Fri Jun 20 15:58:21 2025, Wilfried, Konstantin, Simon, Laser, Laser stepwidth 
From previous Bi-Beamtimes, we expect the width of the transition to be >50GHz (FWHM). The current step width is 0.002nm which corresponds to 8GHz, so the
laser would be in resonance for 6 steps.
We should aim for at least 5 steps in resonance.
Entry  Fri Jun 20 11:25:32 2025, Julien, Kristian, Konstantin, Laser, Automated laser scans  
In contrast to entry [URL=https://elog.gsi.de/esr/E0052_2025/12]E12[/URL], the cabling for the automated start of the laser scan is now connected to [B]IO3
of sddsc221[/B].
Entry  Fri Jun 20 06:37:51 2025, Konstantin, Accelerator, Position of contaminants 
I checked the positions of the contaminants. Therefore, I drove the scrapers and observed the signal at the Schottky detector

While the vertical positions are identical for all scrapers, the horizontal positions deviate due to the dispersion in the cooler section