Entry  Mon Mar 3 12:47:08 2025, Tamina, Rudolfo, Volker, Danyal, Florian, Calibration, Änderung der Ionenenergie 
Änderung der Ionenenergie auf 287,62 MeV/u. 
Gamma = 1,30877
Neue Bunchingfrequenz: 1,78561578504741 MHz
Entry  Tue Mar 4 01:05:33 2025, Sebastian, Benedikt, Denise, Runs, whole range scan @2nd ion energy) without shift 

[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte | Start LMD | Stop LMD | Messdauer (s) | Elektronenkuehlung (s) | Kommentar
Entry  Fri Dec 13 13:44:13 2024, Sebastian, Runs, test 
test 123
Entry  Thu Feb 6 11:03:26 2025, Danyal, General, pressures in laser window sections NW and SW 
The pressures, read by the UHV technician, are : 

E01VVLF1T (E01VMLF1X):           5.84e-10mbar
Entry  Thu Feb 27 11:19:55 2025, Danyal, Accelerator, pictures of the ion beam from 26.02.2025  Schottky_pick-up_Bild.jpgSchottky_resonator_Bild.jpggebunchter_Strahl_im_ESR.jpg
Hier sind noch ein paar Bilder vom Ionenstrahl , wie er gestern Abend war.
Entry  Mon Mar 3 15:40:39 2025, Tamina, Danyal, Calibration, necessary tests on 03.03.2025 before 08:00 AM 
We must test the following, shortly before beamtime end:

Without ion beam:  
Entry  Tue Feb 11 13:08:32 2025, Danyal, Accelerator, limited access to ESR this week 
Hitrap will kein ESR Zugang erlauben bevor 22 Uhr. Außerdem merken die, wenn ESR-SIS nicht laufen, dass sie morgens immer 1 Stunde Zeit verlieren weil nicht
"angefordert" wurde. Deswegen wollen sie, dass ESR-SIS nachts auch weiter Strahl anfordern, etwa 1 mal pro 5 Minuten. Aber wir finden schon noch eine Lücke
um reinzugehen.
Entry  Tue Feb 11 10:30:21 2025, Danyal, General, laser valves are open 
Die Laserventile im ESR sind nun offen. Der Laserstrahl darf durchgeschossen werden.

The "laser valves" (NW and SW) are now open.  The laser beam may pass through the ESR. 
Entry  Mon Mar 3 13:15:51 2025, Tamina, Florian, Volker, Danyal, Calibration, frequencies 
f_bunch = 1.785 615 785 047 41 MHz 
f_rev = f_bunch
Entry  Mon Mar 3 01:53:18 2025, Sebastian, Denise, Benedikt, Runs, extending the lower wavelength range (no shift) 
We will extend the min normal scan range by 3 measurements 

[TABLE border="1"]
Entry  Sun Mar 2 23:05:16 2025, *Jens, Reinhold, Danyal, DAQ, extended normal scan range (no shift): 257.6750 - 257.8022 nm 
We will extend the max normal scan range by 3 measurements 

[TABLE border="1"]
Entry  Mon Mar 3 16:19:18 2025, Konstantin, DAQ, changed shutter timing - effective from 03.03.2025 @ 16:24 ! changed_shutter_timing.jpgchanged_shutter_timing_in_DAQ.jpg
The power and the fluctuations of the laser should be recorded in the XUV Data, so that the rate can be corrected. 
Therefore the shutter timing was changed. 
Entry  Mon Mar 3 16:27:13 2025, Danyal, Accelerator, bunch length @ new ion energy bunch_measurement_1_-_2nd_energy.jpgbunch_measurement_2_-_2nd_energy.jpgbunch_measurement_-_2nd_energy.jpg
the bunch length was measured for the new ion energy. 
It is about 60 ns.  This is shorter than before.
Entry  Tue Feb 11 10:32:01 2025, Danyal, General, access to ESR 
Es wird noch zwei 2 stündige Unterbrechungen am UNILAC geben. Wahrscheinlich diesen Freitag und nächste Woche Mittwoch oder Donnerstag. Am 25.2. wird dann
die Gleitringdichtung der Pumpe am UNILAC gewechselt (8-18 Uhr) daher rechne ich mit Xe Strahl im ESR frühestes am 26.2.
Von HITRAP habe ich erfahren, dass wir Abends/Nachts was im Ring machen dürfen, ab 22 Uhr. z.B. am 17.2, 19.2 und 21.2.  Aber ich denke vorher (diese Woche)
Entry  Tue Feb 11 10:35:38 2025, Danyal, Detectors, XUV detector 
Volker Hannen kommt am 19.2 (Mittags) und dann machen wir Abends den XUV Detektor bereid.

Entry  Tue Mar 4 07:07:11 2025, Sebastian, Benedikt, Denise, Detectors, XUV Detektor Laseruntergrund 
Laseruntergrund XUV Detektor krzpton0554.lmd

Schritte:
Entry  Tue Mar 4 08:46:43 2025, , General, Wir sagen Daaaankeeeschooooeeeeeeeen 
40 Jahre die Flippers
Entry  Sat Mar 1 09:49:06 2025, Tamina, Florian, Konstantin, Volker, Calibration, Vorbereitung Messung Verschiebung Laserpulse zum Bunch 
Nach dem Zyklus liegen die PD-Pulse nicht mehr bei 55 bins (SW) und 85 bins (NW) wie vorher, sondern bei 56 (SW) und 87 (NW) 
- Pulse laufen Richtung Nord, also in die "schlechte" Richtung, wo man eventuell den XUV-Detektor verfehlt.
- Bunch bei ca. 70-75 
Entry  Fri Feb 14 16:41:54 2025, Sebastian , General, Verkabelung PD ESR IMG_8368.jpeg
Verkabelung von den Photodioden im ESR. Sind auch gelabelt.

PD gehen zuerst einmal in den FAMP (10x Verstärkung) 
Entry  Fri Feb 28 20:44:04 2025, Konstantin, DAQ, Updated Channel list 
Final (hopefully) channel list: