Thu Feb 27 21:23:02 2025, Jens, DAQ, Python Data Channels
|
Python variables and names in DAQ
Because the Name of variables in DAQ doesnt match the the real variables, here is List of the channels and what value is in this channel
|
Thu Feb 27 20:21:31 2025, Sebastian, General, 10 MHz Ref Clock (Butis)
|
10 MHz Referenz Clock von BUTIS mit AFG als externl clock verbunden.
Wird benötigt das die Bunch Kavität (DDS System) in Phase mit AFG (Laserreprate) ist. |
Thu Feb 27 16:30:57 2025, Konstantin und Rodolfo, DAQ, HF Signal
|
We have exchanged the HF-Signal in the DAQ Electronic: from Dummy-HF to the real HF from accelerator. |
Thu Feb 27 11:19:55 2025, Danyal, Accelerator, pictures of the ion beam from 26.02.2025  
|
Hier sind noch ein paar Bilder vom Ionenstrahl , wie er gestern Abend war. |
Thu Feb 27 10:52:32 2025, Rodolfo, Detectors, Taking PMTs into operation 
|
[B]PMT Nord[/B] the power supply (CH0) is giving an alarm already by an applied voltage of -1707 V (operation voltage is -2450 V). It is leaking to much
current, larger than the set value of 310 uA. See attached picture 20250227_105411.jpg .
|
Thu Feb 27 09:59:08 2025, Konstantin, Calibration, HV-Divider
|
The readout of the HV divider runs on a RaspberryPi inside the HV-cave of the electron cooler.
Starting from 2025-02-27 09:42, the divider ratio was changed from 248517 to 248515. Usually, the
readout should run continuously. If not, the following procedure must be applied:
|
Thu Feb 27 09:38:04 2025, Konstantin & Danyal, Detectors, Laufzeit Messungen
|
Gestern Abend haben wir die Signal Laufzeiten im gemessen:
PMT Mitte: 1213 ns (bis zur Messhütte ohne DAQ sind es 1025 ns)
|
Wed Feb 26 18:53:52 2025, Danyal, Accelerator, ESR settings
|
Date: 26.02.2025 @ 18:35
E-cooler: HV = 157366 +/- 1 V (HV divider value)
|
Tue Feb 25 14:51:52 2025, Danyal, General, Experiment Acceptance
|
Today, 25 FEB 2025 at 9:00 AM, our experiment was reviewed carefully by the safety committee.
The experiment was accepted without problems.
All was fine, only minor comments were made and only a few short-notice actions were required.
|
Tue Feb 25 13:12:01 2025, Sebastian, DAQ, Teilungsverhältnis Ohmlabs HVS250 
|
Hochspannung Maßstabsfaktoren
-140 kV >>> 248514
|
Thu Feb 20 13:51:04 2025, Denise, Sebatian, DAQ, DAQ Channelliste
|
[TABLE border="1"]
TDC Channels |
|-
|
Thu Feb 20 13:37:30 2025, Denise, Sebastian, DAQ, CFD Schwellen DAQ
|
Schwellen fuer den CFD N842 (lascool)
Lasereinstellungen dabei waren: 0.5 Skalenteile -> 115ps Pulse
3.56654MHz Reprate
|
Thu Feb 20 00:45:00 2025, Danyal, General, Doppler width of M1 transition
|
According to Paul Indelicato
transition 3P1 -> 3P0 in 78Kr32+ :
|
Mon Feb 17 13:49:20 2025, Denise, General, Frequenzbreiten Ionensystem
|
Berechnung der Frequenzbreiten des Lasers im Ionensystem
Werte für die Frequezbreiten des Lasers aus Dissertation Benedikt Langfeld übernommen
|
Fri Feb 14 16:41:54 2025, Sebastian , General, Verkabelung PD ESR
|
Verkabelung von den Photodioden im ESR. Sind auch gelabelt.
PD gehen zuerst einmal in den FAMP (10x Verstärkung)
|
Fri Feb 14 16:24:22 2025, Denise, General, Strahlprofil UV im ESR  
|
Erstes Bild ist das Strahlptofil in Höhe des Nord
towers.
Zweites Bild (mit Millimeterpapier) und Video zeigt
|
Thu Feb 13 12:56:01 2025, Danyal, General, ESR access - monday (whole day) 8-18 hr
|
|
Thu Feb 13 12:55:13 2025, Danyal, General, ESR access - tomorrow (Fri) 10:00 - 12:00
|
|
Wed Feb 12 12:48:48 2025, Danyal, General, ESR access
|
We had the chance to shortly enter the ESR, between 10:45 and 11:30.
- We repositioned the PSDs of the TEM system.
|
Tue Feb 11 13:08:32 2025, Danyal, Accelerator, limited access to ESR this week
|
Hitrap will kein ESR Zugang erlauben bevor 22 Uhr. Außerdem merken die, wenn ESR-SIS nicht laufen, dass sie morgens immer 1 Stunde Zeit verlieren weil nicht
"angefordert" wurde. Deswegen wollen sie, dass ESR-SIS nachts auch weiter Strahl anfordern, etwa 1 mal pro 5 Minuten. Aber wir finden schon noch eine Lücke