  66   Sat Mar 1 07:14:48 2025 Night shiftRunsTabelle erster Scanbereich 257.175 nm - 257.300 nm[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte
| Start LMD | Stop LMD | Messdauer (s) |
  
  44   Fri Feb 28 00:19:04 2025 Konstantin, SebastianDetectorsPMT power supplyWe checked the PMT signal inside the cave
by using the local HV power supply. If one
needs to repeat the measurement at another
 Screenshot_2025-02-28_00-33.png 
  39   Thu Feb 27 16:30:57 2025 Konstantin und RodolfoDAQHF SignalWe have exchanged the HF-Signal in the DAQ
Electronic: from Dummy-HF to the real HF
from accelerator. 
  
  35   Thu Feb 27 09:38:04 2025 Konstantin & DanyalDetectorsLaufzeit MessungenGestern Abend haben wir die Signal Laufzeiten
im gemessen:
  
  70   Sat Mar 1 13:45:42 2025 Konstantin DAQGentec readoutGentec readout is now included in the general
slow data acquisition. The issue was that
the buffer of the power meter was not emptied
  
  36   Thu Feb 27 09:59:08 2025 KonstantinCalibrationHV-DividerThe readout of the HV divider runs on a RaspberryPi
inside the HV-cave of the electron cooler.
Starting from 2025-02-27 09:42, the divider
  
  52   Fri Feb 28 15:53:44 2025 KonstantinAcceleratorHF Signal for BunchingThe HF Bunching Frequency is: 1.7838817 MHz

Given (read) by the ESR operators in HKR.
  
  55   Fri Feb 28 17:36:15 2025 KonstantinDAQTrigger events from accelaratorWe will use GENESIS to create trigger events
(injection, ...) for the DAQ
 2025-02-28_17-34-15-990_1.png 
  57   Fri Feb 28 20:44:04 2025 KonstantinDAQUpdated Channel listFinal (hopefully) channel list:

[TABLE border="1"]
  
  71   Sat Mar 1 16:33:22 2025 KonstantinDAQRestart of Go4 Restart of go4 before new scan:

1. Stop Acquisition (Stop button right next
 Screenshot_2025-03-01_16-34-01.pngScreenshot_2025-03-01_16-45-30.png 
  74   Sat Mar 1 19:19:25 2025 KonstantinDAQOffline AnalysisA copy of the current go4 analysis is placed
at atplaser@lxgs1055:/kr_analysis. Use the
usual Go4 startup routine to start an offline
 Unbenanntes_Bild.pngg042.png 
  93   Mon Mar 3 16:19:18 2025 KonstantinDAQchanged shutter timing - effective from 03.03.2025 @ 16:24 !The power and the fluctuations of the laser
should be recorded in the XUV Data, so that
the rate can be corrected. 
 changed_shutter_timing.jpgchanged_shutter_timing_in_DAQ.jpg 
  80   Sun Mar 2 16:51:53 2025 Jens, RodolfoGeneralSpaetschichtDie Spaetschicht macht weiter, bzw. mit dem
naeschten Scan (um 16:41 Uhr) angefangen.
Siehe bitte Eintrag 75 (noch als Preview
  
  81   Sun Mar 2 18:55:30 2025 Jens, Reinhold, DanyalDAQMain Scan range (4 blocks) shifted by -0.0012 nm --> one more scanWe decided to scan the main range, shifted
by -0.0012nm, one more time in order to have
the non-shifted AND the shifted range both
  
  97   Mon Mar 3 20:14:10 2025 Jens, Konstantin, Reinhold, DanyalDAQ-0.0012 nm shifted whole range scan (@2nd ion energy)
[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte
  
  41   Thu Feb 27 21:23:02 2025 JensDAQPython Data ChannelsPython variables and names in DAQ
Because the Name of variables in DAQ doesnt
match the the real variables, here is List
  
  73   Sat Mar 1 18:32:05 2025 JensRunsLaser während Scan18:30Uhr:
Timestamp im Programm hat gehangen. Kurz
im Anzeigefeld markieren und es ging wieder.
  
  96   Mon Mar 3 16:40:42 2025 Denise, Tamina, Bene, Sebastian, JensCalibrationTODO Lasercrew vor Ende der MesszeitPrio 1: Gentec Suedwest kalibrieren (Wichtig
fuer Auswertung)
Prio 2: Messung Strahlwanderung mit Wincam
  
  31   Thu Feb 20 13:51:04 2025 Denise, SebatianDAQDAQ Channelliste[TABLE border="1"]
TDC Channels |
|- 
  
  47   Fri Feb 28 04:47:39 2025 Denise, Sebastian, BenediktCalibrationGentec ESR KalibrationUnsicherheiten Gentecs im allgemeinen bei
etwa 6.5%
  