ID Date Author Category Subject
  331   Fri Apr 11 15:57:37 2025 ShahabGeneralMore screenshots of RSAs
more screen shots of RSAs.
  330   Fri Apr 11 15:49:41 2025 ShahabGeneralScreenshots of RSAs
Screenshots of RSAs showing acquisition settings, for documentation, they show the time / date on the bottom left, in case needed for data analysis.
  329   Wed Apr 9 11:18:27 2025 EstherDAQNTCAP off, RSA triggers disconnected
The NTCAP computer and crate are switched off.
The triggers are disconnected from the RSAs, but they remain on.
  328   Wed Apr 9 11:09:48 2025 WolframGeneralThanks to everybody for their committment to perform this experiment
  327   Wed Apr 9 11:03:48 2025 Yuri, Sergey, EstherGeneralFinal Injection
> The a final injection from SIS18 stored at 10:04.
> The scrapers were moved out before to get the maximum intensity.
> NTCAP is still running, the RSAs recorded the last files at 10:04.
> The plan is to keep running like this for about an hour.

Beam stopped at 10:58.
NTCAP and RSAs are stopped.
  326   Wed Apr 9 10:24:54 2025 Yuri, Sergey, Nikos, EstherGeneralFinal Injection
The a final injection from SIS18 stored at 10:04.
The scrapers were moved out before to get the maximum intensity.
NTCAP is still running, the RSAs recorded the last files at 10:04.
The plan is to keep running like this for about an hour.
  325   Wed Apr 9 10:08:08 2025 Nikos, EstherGeneralScreenshots
Lassie exports from the last morning shift + screenshot of Schottky TV after the last injection from SIS
  324   Wed Apr 9 09:30:14 2025 YuriGeneralSlit changing
I would like to close E01 slits a bit more and get 30 min of data with higher 
resolving power.

EEX scraper from -10 now -1
E01 unchanged
  323   Wed Apr 9 06:47:51 2025 Esther, NikosGeneralBrief beam interruptions
There was no beam from SIS between about 06:28 and 06:39.

Again from 07:02 to 07:11.

And again from 07:49 to 07:55.
  322   Wed Apr 9 00:08:30 2025 Sergey, Yuri and XinliangGeneralMove of the scraper positions at ESR
From roughly … to 0:05AM, Sergey moved GEEXDS1HA (not 
changed 
in the end) and GE01DS3HG (changed from -85 to -80 mm) to reduce 
the acceptance of the ESR to improve the mass resolution.

After the change, there are less small traces appearing in the 
413.55735 MHz +/-5 kHz range. 

The final positions of the two scrapers are 
GEEXDS1HA :-10 mm; GE01DS3HG:-80 mm.
  321   Tue Apr 8 23:08:15 2025 Sergey Litvinov, Xinliang YanGeneralTuning of the ion optics
From roughly 10:45 pm to 11:05 pm,  Sergey tuned the 
ion optics of the ESR to see if the mass resolution at 
413.55735 MHz improves or not. Please note that the 
frequencies of ions during the tuning process are not 
stable.

Q-magnets and S-magnets have been adjusted, see 
accelerator E-logs ID-844 titled ‘ ESR seting for 
204Pt77+’ created by Sergey.
  320   Tue Apr 8 21:56:37 2025 Shahab, Michael, XinliangDAQnew settings
last file with old setting:

RSA01-2025.04.08.21.55.22.661.tiq

new plunger position 410: 13mm
new plunger position 245: 390mm

new frequency 410: 413555918
new frequency 245: 243.497403


first good file in this setting:

RSA02-2025.04.08.22.09.53.178.tiq
  319   Tue Apr 8 20:50:59 2025 Ruijiu ChenAnalysisPID of 204Pt77+
  318   Tue Apr 8 20:29:24 2025 Michael, ShahabDAQnew DAQ settings
NTCAP Started

RSAs started:

New plunger settings for 410 --> 20mm
frequencies: 410 -->
245 -->

recording time: 1.7s
ACQ BW--> 5 MHz
fs --> 6.25 MSPS
trigger --> 8%

lframes = 65536
nframes = 160

first good file in this setting is: 20:34 onwards
  317   Tue Apr 8 14:16:16 2025 Michael, CaglaGeneralBeam stopped for Accelerator Tour etc.
The beam was stopped for the evaluation accelerator tour. RSAs and NTCAP stopped now.
  316   Tue Apr 8 13:47:33 2025 Cagla, MichaelGeneralLassie Screenshots
New sextupole settings at 13.45.
The beam will be stopped at 14.10 until around 7 pm.
  315   Tue Apr 8 13:46:20 2025 Michael GeneralTrying new Sextupole settings, all data after 13:44 affected
  314   Tue Apr 8 13:01:29 2025 Cagla, MichaelGeneralLassie Screenshots
  313   Tue Apr 8 12:10:41 2025 Cagla, MichaelGeneralLassie Screenshots
  312   Tue Apr 8 12:08:56 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 188Hf72+ setting 2
This is sigma vs Freq plot for 188Hf72+ made out of 1hr of injections post Saturday, April 5th. 
The 2nd photo Compares the resolution of 188Hf setting by looking at peaks of 205Au and 205Pb which are very close in frequency range. The resolution in the second 188Hf72+ setting(on Right) seems much better as two peaks can be seen clearly. 
  311   Tue Apr 8 11:57:56 2025 Team PLEIADESDetectorsOutside detector moved out
12:00 Outside particle detector moved out to parking position again (-125 mm)
  310   Tue Apr 8 11:37:13 2025 Team PLEIADESDetectorsPLEIADES
11:37 Outside particle detector (GE01DD2AG) moved in to -100mm to take data
  309   Tue Apr 8 11:18:06 2025 Cagla, MichaelGeneralLassie Screenshots
  308   Tue Apr 8 10:13:51 2025 Team PLEIADESDetectorsMoved outside particle detector back into parking position
10:16 Moved outside particle detector back into parking position (-126mm)
  307   Tue Apr 8 10:04:02 2025 Cagla, MichaelGeneralLassie Screenshots
  306   Tue Apr 8 09:53:04 2025 Team PLEIADESDetectorsMoving outside particle detector in for 20min
9:53 Data taking with outside detector (GE01DD2AG) moved in to -110mm
  305   Tue Apr 8 09:28:49 2025 Team PLEIADESGeneralControlled access to ESR to connect cables for DAQ
We will need to enter the ESR to connect the cables again for our DAQ and then drive in the outside detector for 20min to get some data.
9:35 entered
9:41 exit
9:44 ESR available again
  304   Tue Apr 8 08:59:24 2025 Cagla, MichaelGeneralLassie Screenshots
  303   Tue Apr 8 07:58:00 2025 Cagla, MichaelGeneralLassie Screenshots
The beam is gone in ESR via TE (FAST) and also in SIS18_RING (FAST) starting from 07.51 am until 07.59 am.
  302   Tue Apr 8 07:00:46 2025 Cagla, Michael GeneralLassie Screenshots
  301   Tue Apr 8 05:53:09 2025 CJ, BWGeneralLassie screenshots
  300   Tue Apr 8 04:50:06 2025 CJ, BWGeneralLassie screenshots
  299   Tue Apr 8 03:48:49 2025 CJ, BWGeneralLassie screenshots
  298   Tue Apr 8 02:47:00 2025 CJ, BWGeneralLassie screenshots
  297   Tue Apr 8 01:48:12 2025 CJ, BWGeneralLassie screenshots
  296   Tue Apr 8 00:49:54 2025 CJ, BWGeneralLassie screenshots
  295   Mon Apr 7 23:49:49 2025 BW, CJGeneralLassie screenshots
  294   Mon Apr 7 22:46:34 2025 Oliver, Filip, CalumGeneralLassie screenshots
  293   Mon Apr 7 21:45:35 2025 Oliver, FilipGeneralLassie screenshots
  292   Mon Apr 7 20:46:04 2025 Oliver, FilipGeneralLassie screenshots
  291   Mon Apr 7 19:41:31 2025 Oliver, FilipGeneralLassie screenshots
  290   Mon Apr 7 18:58:04 2025 ShahabDAQchanged averaging in NPZ files
new analysis settings for NPZ files:

[analysis]
nframes = 190
lframes = 65536
navg = 1


first file with this setting:

'RSA02-2025.04.07.18.57.17.454.tiq', 'RSA02-2025.04.07.18.57.02.328.tiq', 'RSA02-2025.04.07.18.58.17.958.tiq', 'RSA02-2025.04.07.18.57.40.143.tiq', 'RSA02-2025.04.07.18.58.25.520.tiq', 
'RSA02-2025.04.07.18.57.09.892.tiq', 'RSA02-2025.04.07.18.57.32.580.tiq', 'RSA02-2025.04.07.18.57.25.017.tiq', 'RSA02-2025.04.07.18.58.10.395.tiq', 'RSA02-2025.04.07.18.57.55.271.tiq', 
'RSA02-2025.04.07.18.56.54.765.tiq', 'RSA02-2025.04.07.18.58.02.833.tiq', 'RSA02-2025.04.07.18.57.47.707.tiq', 'RSA02-2025.04.07.18.56.47.202.tiq'
  289   Mon Apr 7 18:52:15 2025 Shahab, OliverDAQupdated DAQ settings
changed 410 resonance frequency back to plunger 8
245 MHz plunger stays at 350


center freq:
410 at 414.474 MHz
245 at 244.000 MHz

first good files in this setting are 18:51 onwards.

everything else remains same like last time.
  288   Mon Apr 7 18:42:17 2025 Oliver, FilipGeneralLassie screenshots
  287   Mon Apr 7 18:37:41 2025 Shahab, OliverDAQupdated DAQ settings
changed 410 resonance frequency back to 212th harmonic
plunger 33

center freq:

410,600 MHz

first good files in this setting are 18:36 onwards.

everything else remains same like last time.
  286   Mon Apr 7 18:17:41 2025 Shahab, OliverDAQupdated DAQ settings
changed 410 resonance frequency back to 213th harmonic
plunger 20

center freq:

412.537 MHz

first good files in this setting are 18:16 onwards.

everything else remains same like last time.
  285   Mon Apr 7 17:51:15 2025 ShahabGeneralHowTo change resonance frequency of 410 MHz Cavity
step by step pictures:

sometimes the name of the motor connection is not available in the menu, it should be added manually.

Add MBOX:

put some name, like "410 MHz Schottky Cavity in ESR"
put the IP address: 140.181.139.194

press connect

change to local control

press initialize

go to motor drive

go to motor 1 and 2

always move same value for both motors.
  284   Mon Apr 7 17:26:57 2025 Shahab, OliverDAQNew DAQ Settings
new DAQ Settings for the RSAs:

414475588 (192Pb+82   at 214 harmonic)
244.03689

plunger settings: 410 MHz cavity--> 8
245MHz cavity --> 350


recording at 50 MSPS
2^16 points each frame -->  1ms per frame

Average set to: 5 frames --> total of ca. 6.5 ms per average frame

first good NPZ file from this settings on RSAs starts from 17:41
  283   Mon Apr 7 17:25:00 2025 Oliver, FilipGeneralLassie screenshots
  282   Mon Apr 7 17:18:45 2025 Wolfram, Yuri, SergeyGeneralData from last 10 minutes are not useful (setting ESR)
  281   Mon Apr 7 17:07:33 2025 Team PLEIADESDetectorsMoving OUTSIDE PLEIADES detector slowly in (and out)
17:08 Tried to move outside particle detector (GE01DD2AG) in - it is stuck again :-(
17:18 Sergey tried to move it, now it moves again. Moved to -100 mm.
17:30 Moved detector to outside parking position
  279   Mon Apr 7 16:19:30 2025 Oliver, FilipGeneralLassie screenshots
  278   Mon Apr 7 16:11:44 2025 Ruijiu Chen, Yuri, Wolfram,AnalysisPID of 192Pb+82
  277   Mon Apr 7 16:07:42 2025 ShahabGeneralall config files
here are all TOML config files of the automatic scripts.
  276   Mon Apr 7 15:47:03 2025 Shahab, Taka, RuijiuDAQchange NAS and restart both acquisitions
changed storage place to bank 1 of the NAS
restarted the NTCAP with new address
restarted Analyzers with new address
restarted the queqiao script
restarted looper scripts

new files on RSAs start from:

2025-04-07 15:23 onwards

new files on NTCAP have their corresponding time stamp on the directory
  275   Mon Apr 7 15:23:01 2025 Ragan, Wolfram, Sergey, Zsolt, Yuri, Rui-JiuGeneralESR Setting change to 192Pb82+
Today, until 11 am, data were taken for the 188Hf setting. Since then, we are now tuning on the 192Pb82+.
  274   Mon Apr 7 15:14:54 2025 Oliver, FilipGenerallassie screenshots
  273   Mon Apr 7 14:05:40 2025 Jelena, GuyGeneralLassie screenshots
  272   Mon Apr 7 13:18:27 2025 Jelena, GuyGeneralTuning
Beam was gone at 13:04 due to fragment tuning.
  271   Mon Apr 7 12:29:16 2025 Jelena, GuyGeneralLassie screenshots
  270   Mon Apr 7 11:35:23 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 186Hf setting
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from April 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr limit 100, about 5200 injections.( the green vertical line is at 411.843 and not at 411.7) 
  269   Mon Apr 7 11:26:52 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 186Hf setting
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from april 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr-limit 100. About 5200 Injections.
  268   Mon Apr 7 11:18:03 2025 Ruijiu ChenAnalysisSimulation Results for 192Pb
  267   Mon Apr 7 10:49:04 2025 Jelena, GuyGeneralBeam stops for tuning
We stop taking beam at 10:47 for tuning a new setting. 

Team PLEIADES is wanting to get access for 10 mins to install a remote oscilloscope, so entry to the ESR has been requested. 
  266   Mon Apr 7 10:40:33 2025 Team PLEIADESGeneralEnter ESR
At 10:45 we will enter the ESR and install a remote oscilloscope for the PLEIADES outside detector. Should take only 10 "GSI" minutes ;-)
After that, ESR tuning to 192Pb can start.
  265   Mon Apr 7 10:04:49 2025 Jelena, GuyGeneralLassie screenshots
  264   Mon Apr 7 09:16:17 2025 Jelena, GuyGeneralLassie screenshots
  263   Mon Apr 7 08:03:07 2025 Jelena, GuyGeneralLassie screenshots
  262   Mon Apr 7 07:09:01 2025 Jelena, GuyAcceleratorBeam interruption, FRS
Beam is gone since 7:02. Control room is notified. Beam is back since 7:14. FRS started taking spills.
  261   Mon Apr 7 07:04:06 2025 Siddharth, Dima, Jelena, GuyGeneralLassie screenshots
  260   Mon Apr 7 06:09:30 2025 Siddharth, DimaGeneralLassie screenshots
FRS started taking beam from 6:00 Am
  259   Mon Apr 7 05:04:59 2025 Siddharth, DimaGeneralLassie screenshots
  258   Mon Apr 7 03:58:58 2025 Siddharth, DimaGeneralLassie screenshots
  257   Mon Apr 7 03:25:41 2025 Siddharth, Dima Collaborationmesycontrol does not start GUI
mesycontrol process starts but shows no GUI at all.

Around 02:51 we wanted to record leakage currents for PLEIADES. 
The windows of the mesycontrol were not present on the screens. 

We followed the instructions for restart:
-ssh -X into x86l-128 (-X is important, otherwise qt will not be initialized)
-mesycontrol

as a result we see nothing but the terminal is busy, and the process exists. 
We noticed that ssh connection establishes very slow, the terminal after the connection responds to typing with a delay of several seconds(one press 'm', after 1-2 sec that letter appears on 
the screen).
 
htop hanged the terminal entirely without showing a thing. Several minutes before we started htop and 12th thread(processor?) has been fully busy, 100%.

our assumption is that GUI has been closed because computer had not enough resources for sustaining it. We would not expect such a slow response even in terminal. 
Could anybody have a look on x86l-128 and figure out why is it so slow? 

UPD: started mesycontrol around 03:40, until 04:02 nothing happened except first two commands. 
Tried to start it from x86l-124 and everything works fine except that the connection to /dev/tty/USB0 can't be established (because it is occupied by x86l-128?)
So we are not able to read leakage currents. 

 
  256   Mon Apr 7 02:56:47 2025 Siddharth, DimaGeneralLassie screenshots
  255   Mon Apr 7 02:02:47 2025 Siddharth, DimaGeneralLassie screenshots
  254   Mon Apr 7 01:05:11 2025 Siddharth, DimaGeneralLassie screenshots
  253   Sun Apr 6 23:59:09 2025 Siddharth, DimaGeneralLassie screenshots
  252   Sun Apr 6 23:51:33 2025 Siddharth, DimaSimulationsLISE file for the 192Pb setting
  251   Sun Apr 6 22:57:47 2025 siddharth, dima, Taka, MoriguchiGeneralLassie screenshots
  250   Sun Apr 6 22:53:53 2025 MichaelAnalysisAdded shift tracking and power threshold to Shahab's npz_addup.py
I added automatic shift tracking and a check for a minimum wanted power in that bin to Shahab's npz_addup.py script.
It looks for the highest bin in the projected spectrum (so after time-cut) and tracks it position. Careful, it uses the position in the very first FILE as reference. So, the ordering in the given file list affects this.

Here's Shahab's log entry about the initial script:
https://elog.gsi.de/esr/E0203_E0018/137

Created pull request in Shahabs repo:
https://github.com/xaratustrah/e0018_e0203_scripts/pull/1

Before that is accepted, find the script here:
https://github.com/mijja-koeln/e0018_e0203_scripts/blob/main/npz_addup.py


New command line options are:
  -h, --help            show this help message and exit
  -t TIME_CUT, --time-cut TIME_CUT
                        Start time as a float (optional)
  -s, --shift-track     Enable shift tracking based on strongest peak in spectrum (optional)
  -l PWR_LIMIT, --pwr-limit PWR_LIMIT
                        Set minimum power required to process file (optional)
  -v, --verbose         Print additional information (optional)


"-s" enables shift tracking and correction.

"-l" enables power limit / threshold. Only files with at least this power in the highest bin are used for summation.

"-v" prints infos abuot the tracking in each file. Optional, if you want to see how good it works.

The --time-cut option is applied in all scenarios, i.e. also before projection used for tracking.

Have fun!
  249   Sun Apr 6 22:22:46 2025 Taka, MoriguchiGeneralLassie screenshots
  248   Sun Apr 6 21:29:37 2025 Taka, MoriguchiAcceleratorBeam sharing
again, ESR : FRS = 1 : 1
  247   Sun Apr 6 21:12:07 2025 Taka, MoriguchiGeneralLassie screenshots
  246   Sun Apr 6 20:49:25 2025 Ruijiu ChenAnalysisSpectrum during April 6 20:00- 20:19
  245   Sun Apr 6 20:13:03 2025 Taka, MoriguchiAcceleratorBeam sharing
Now we have every injection.
  244   Sun Apr 6 19:42:23 2025 Taka, MoriguchiGeneralLessie screenshots
  243   Sun Apr 6 19:23:09 2025 Shahab, Moriguchi, TakaAcceleratorBeam sharing
Beam sharing with FRS is now 1 to 1.
  242   Sun Apr 6 18:48:36 2025 Shahab, Moriguchi, TakaAcceleratorBeam back
Beam is back now.
  241   Sun Apr 6 18:42:51 2025 Shahab, Taka, MoriguchiGeneralLassie screenshots
  240   Sun Apr 6 18:36:56 2025 Shahab, Moriguchi, TakaAcceleratorBeam stopped
Beam stopped due to device trouble.
  239   Sun Apr 6 17:29:04 2025 Ruijiu ChenAnalysis188Hf72+ spectrum and single ion line from NTCAP data
This shows the spectrum of 188Hf72+ during "April06_01:00_02:00". Until April 6 2:00, the Bp = 7.918262 Tm has not been changed. 
The ntcap spectrum is from:
/data.local/G22-00018_00203/results/ntcap/iq/IQ_2025-04-05_17-43-49/0000756.iq.tdms.root


analysis settings:

2^18 samples per frame + average over 32 frame.
26.21 ms per frame
838.86 ms for 32 averaged frames
  238   Sun Apr 6 17:24:47 2025 Shahab, Taka, MoriguchiGeneralLassie screenshots
  237   Sun Apr 6 16:24:36 2025 Wolfram, Shahab, Moriguchi, TakaDAQNTCAP restart
NTCAP restarted with new timestamp.
  236   Sun Apr 6 16:16:22 2025 Wolfram, Shahab, Taka, MoriguchiGeneralLassie screenshots
  235   Sun Apr 6 15:13:47 2025 Burcu, Moriguchi, Taka, GregorGeneralLassie screenshots
  234   Sun Apr 6 14:17:07 2025 Ragan, Burcu, Gregor , Yuri, TakaGeneralEvery injection to the ESR
From 14:15, we have every injection to the ESR. FRS is on pause for 1-2 hours.
  233   Sun Apr 6 13:54:25 2025 Ragan, Burcu, GregorGeneralLassie screenshots
  232   Sun Apr 6 12:57:23 2025 Ragan, Burcu, GregorGeneralLassie screenshots
  231   Sun Apr 6 11:54:45 2025 Ragan, Burcu, GregorGeneralLassie screenshots
  230   Sun Apr 6 10:55:23 2025 Ragan, Burcu, GregorGeneralLassie screenshots
  229   Sun Apr 6 09:51:30 2025 Ragan, Burcu, GregorGeneralLassie screenshot
  228   Sun Apr 6 08:53:29 2025 Ragan, GregorGeneralLassie screenshots
  227   Sun Apr 6 07:54:32 2025 Ragan, GregorGeneralLassie screenshots
  226   Sun Apr 6 06:51:08 2025 Hongfu LI, Xing Xu, Gregor KosirGenerallassie screen shot
  225   Sun Apr 6 06:27:50 2025 Hongfu Li, XIng XuGeneralLassie screen shot
  224   Sun Apr 6 05:34:29 2025 Hongfu Li, Xing XuGeneralLassie screen shot
  223   Sun Apr 6 04:30:13 2025 Hongfu Li, Xing XuGeneralLassie screen shot
  222   Sun Apr 6 03:31:05 2025 Hongfu Li, XIng XuGeneralLassie screen shot
  221   Sun Apr 6 02:58:43 2025 Hongfu Li, XIng XuGeneralSIS no beam for a moment and beam back soon after call main control room
  220   Sun Apr 6 02:33:53 2025 Hongfu Li, Xing XuGeneralLassie screen shot
  219   Sun Apr 6 01:34:53 2025 Hongfu Li, Xing XuGeneralLassie screen shot
  218   Sun Apr 6 00:34:17 2025 Hongfu Li, Xing XuGeneralLassie screen shot
  217   Sat Apr 5 23:31:54 2025 Hongfu Li, Xing XuGeneralLassie screen shot
  216   Sat Apr 5 22:28:23 2025 Xinliang Yan, Wenwen GeGeneralLassie screen shot
  215   Sat Apr 5 21:16:17 2025 Xinliang Yan, Wenwen GeGeneralLassie screen shot
  214   Sat Apr 5 20:58:37 2025 ShahabDAQremoved temporary NPZ files for additional disk space
Deleted 14 TB of unused spectrum.npz files from APPC, so that there is more disk space.

switched off the production of .tiq_spectrum.npz files to save disk space in the looper script



Explanation:

.tiq_spectrogram.npz —> 3D NPZ files, that can be used for add up and create small 2D "spectrum" file for RionID

.tiq_spectrum.npz —> 2D NPZ files with super high resolution, noone needs them up to now
  213   Sat Apr 5 20:11:57 2025 Xinliang Yan, Wenwen GeGeneralLassie Screenshot
  212   Sat Apr 5 19:20:32 2025 Team PLEIADESDetectorsOutside detector moved out again
19:20 The outside and inside PLEIADES detectors are both moved back into their parking positions. Shifts should continue monitoring the leakage current on the mesycontrol screens and enter the values every 2h in the Google spreadsheet:
https://elog.gsi.de/esr/Beavertail/34
  211   Sat Apr 5 18:54:38 2025 Xinliang Yan, Wenwen GeGeneralLassie screen shot
  210   Sat Apr 5 18:24:09 2025 Dima, Zac, ShahabDAQRSAs stop again, due to misses
RSAs had to stop because the cycle of 1.8 came too often, both analyzers could not catch up with the file transfer.


changed to 1.7 seconds

last file in the 1.8 setting:

RSA01-2025.04.05.18.20.46.005
RSA02-2025.04.05.18.20.43.346


new filenames from the 1.7 s settings:

RSA01-2025.04.05.18.28.12.146.tiq

new analysis settings:

[analysis]
nframes = 80
lframes = 131072
avg = 4




Explanation:

every file has 10625050 samples with 1.7 seconds length
sampling rate: 6.25 MSPS
this means every sample is worth: 1.6e-7 seconds
this means every frame with length of 2^17 samples will have a time length of: 21 ms
finally with an averaging of 4 frames into one, this means that every time frame in the NPZ file will have 80ms length



frequency setting

please see attached pictures.
  209   Sat Apr 5 17:57:08 2025 Ragan, Dima, Zac, ShahabCalibrationNew Settings Resonators
New settings for resonators:

410: plunger stay the same
center: 411.756955 MHz


245: plunger now at 150
center: 245.507668 MHz


first files on the resonators:


RSA01-2025.04.05.18.09.08.519.tiq
RSA02-2025.04.05.18.09.09.618.tiq
  208   Sat Apr 5 17:45:17 2025 Ragan, Shahab, Dima, ZacDAQrestarted NTCAP
NTCAP restarted 17:43

we have 63% full on bank 2 of the NAS
which means about 11% every day
this gives us roughly another 3 days of recording time
we can always switch to bank 1, but changing that, needs changing the analysis paths. so for now, we continue on bank2

:-)
  207   Sat Apr 5 17:34:14 2025 Team PLEIADESDetectorsMoving outside detector in
17:35 Slowly moving PLEIADES outside detector (GE01DD2AG) in for some data. Clipping ions at -20mm. Leaving detector at -40mm for a few minutes.
  206   Sat Apr 5 17:26:48 2025 Team PLEIADESDetectorsOutside pocket "repair"
We tried to convince the outside pocket to move, no success. We can hear the "hissing sound" of the pressurized air but no movement. Sergey tried to move it from the HKR, also no success. After that I tried to move it again from the Messhuette...and the "Out of tolerance" error message is gone, and the pocket seems to move. (We cannot confirm from inside because the ESR is already closed).
Guess the outside pocket got intimidated by Sergey and decided to get moving again... ;-)

We will take a bit more beam once the setting is stable, but try not to fry another detector.
  205   Sat Apr 5 17:01:30 2025 Ragan, Dima, Zac, ShahabDAQDAQs stopped
NTCAP and analysers are stopped at 17:00.Iris goes inside to move the detectors 
  204   Sat Apr 5 16:54:58 2025 ZsoltGeneral188Hf +72 setting back
The 188Hf72+ setting measurement starts now. Exactly the same setting like two days ago.
  203   Sat Apr 5 16:48:26 2025 Ragan, Wolfram, Sergey, Zsolt, Yuri, Rui-JiuGeneral188Hf72+
Now ESR is set to the 188Hf72+ setting.
  202   Sat Apr 5 16:24:07 2025 Shahab, Dima, ZacDAQrestarted looper script for RSA02
we removed the wrong entries from the PKL file, and restarted the looper script for RSA02.

important change:

nframes = 84 
lframes = 131072
navg = 4



here are the new parameters:

# Config file for the multiprocessing looper script

[paths]
monitor_dir = "/data.local/G22-00018_00203/data/analyzers/RSA02"
output_dir = "/data.local/G22-00018_00203/results/analyzers/RSA02"
state_file = "/data.local/G22-00018_00203/scripts/e0018_e0203_scripts/processed_files_rsa2.pkl"

[processing]
num_cores = 12
interval_seconds = 0.5
file_ready_seconds = 0.5

[analysis]
nframes = 84 
lframes = 131072
navg = 4
zzmin = 0
zzmax = 1e6
mask = false
dbm = false
todo = ['spectrum', 'spectrogram'] # choose any of or combination 'png', 'spectrum', 'spectrogram'
  201   Sat Apr 5 15:45:48 2025 Ruijiu, RaganAnalysisSee single ion of 186Hf72+ and isomer in ntcap data
The ntcap data record 410 detector continuously. The frame length is  26 ms/frame * 32 frames= 832 ms.
  200   Sat Apr 5 15:25:16 2025 ShahabDAQstop RSA02 looper script
2025-04-05 15:25
Stop the RSA02 looper script to change the settings of analysis
  199   Sat Apr 5 15:20:19 2025 YuriGeneralChange to 188Hf
Before changing we check how much we cut with the ESR scrapers
two lines
208Pb80+ with slits intensity 15 arb u
204Hg78+ ... 0.055

Now, slits fully open


208Pb80+ with slits intensity 127 arb u
204Hg78+ ... 0.25

Increase compared to 188Hf measurement:
208Pb80+  increase of factor 8.5
204Hg78+  increase of factor 14
  198   Sat Apr 5 15:15:33 2025 Xinliang Yan, Wenwen GeGeneralLassie screen shots
  197   Sat Apr 5 15:01:03 2025 Hannes, CaglaGeneralLassie screenshots
  196   Sat Apr 5 14:55:21 2025 Team PLEIADESDetectorsMoving detectors in again, to 20mm
14:57 We are moving the inside pocket detector in again, this time to 20mm
  195   Sat Apr 5 14:11:49 2025 Team PLEIADESDetectorsMoving inside pocket detector
14:12 We are moving the inside pocket out for a moment, change the bias
  194   Sat Apr 5 14:02:54 2025 Hannes, CaglaGeneralLassie screenshots
  193   Sat Apr 5 12:59:08 2025 Hannes, CaglaGeneralLassie screenshots
  192   Sat Apr 5 12:22:12 2025 Team PLEIADESDetectorsPLEIADES inside detector in
12:23 moved PLEIADES inside detector in to 2mm.
  191   Sat Apr 5 12:03:23 2025 Hannes, CaglaGeneralLassie screenshots
  190   Sat Apr 5 11:37:44 2025 Ragan, Rui-Jiu, Zsolt, Wolfram, YuriGeneralGeneral
We have not seen 184Hf and 186Hf so far. 
  189   Sat Apr 5 11:04:22 2025 Hannes, CaglaGeneralBeam back
The beam is back as before since 11:02.
  188   Sat Apr 5 11:00:57 2025 Hannes, CaglaGeneralLassie screenshots
  187   Sat Apr 5 10:51:00 2025 Hannes, CaglaGeneralBeam gone
Beam is gone since 10:45.
According to the main control room there is a problem in SIS18. They are looking into the problem.
  186   Sat Apr 5 10:16:11 2025 Hannes, CaglaGeneralLassie screenshots
  185   Sat Apr 5 09:07:21 2025 Ruijiu ChenAnalysisAnalysis during April 4th 16:00-April 5th 8:00
still can not see both 186Hf72+ and 184Hf71+
  184   Sat Apr 5 09:03:36 2025 Hannes, CaglaGeneralLassie screenshots
  183   Sat Apr 5 08:15:09 2025 Hannes, CaglaGeneralParticles are back to previous intensity
  182   Sat Apr 5 08:01:14 2025 Hannes, CaglaGeneralLassie screenshot and drop in particles
After a ~ two minute outage of the "ESR via TE (FAST)" beam at 07:48 the particles dropped by half. See screenshot 2025-04-05_08-01-34-267.png
  181   Sat Apr 5 06:55:59 2025 Yue, Qian, Mayr, HannesGeneralLassie Screenshot
  180   Sat Apr 5 06:01:50 2025 Yue, QianGeneralLassie Screenshot
  179   Sat Apr 5 05:01:36 2025 Yue, QianGeneralLassie Screenshot
  178   Sat Apr 5 04:01:56 2025 Yue, QianGeneralLassie Screenshot
  177   Sat Apr 5 03:02:43 2025 Yue, QianGeneralLassie Screenshot
  176   Sat Apr 5 02:01:44 2025 Yue, QianGeneralLassie Screenshot
  175   Sat Apr 5 01:03:18 2025 Yue, QianGeneralLassie Screenshot
  174   Sat Apr 5 00:06:09 2025 Yue, QianGeneralLassie Screenshot
  173   Fri Apr 4 23:33:51 2025 Ruijiu ChenAnalysisAnalysis during April 4th 16:00-22:00
Until now, there is no 184Hf72+ and 186Hf72+ ions. 
  172   Fri Apr 4 23:01:04 2025 BJ KKGeneralLassie screenshots
  171   Fri Apr 4 22:24:30 2025 BJ BW KKGeneralLassie screenshots
  170   Fri Apr 4 21:21:25 2025 BJ MC ID KKGeneralLassie screenshots
  169   Fri Apr 4 20:48:25 2025 IDGeneralPocket moved
20:48: Inside pocket moved to 60mm and back to the outside position.
  168   Fri Apr 4 20:29:22 2025 KK BJ MCGeneralLassie screenshots
  167   Fri Apr 4 19:19:06 2025 BJ KK MCGeneralLassie screenshots
  166   Fri Apr 4 18:38:52 2025 Dima, Zac, Sid, Kanika, Ragan, Shahab, BeatrizDAQnew file name and settings for 245 MHz
new settings:
1.8 seconds recording on 245 MHz on RSA02

starting from file name:

2025.04.04.18.36.32.895


settings are in the attachment
  165   Fri Apr 4 18:24:31 2025 BJ KKGenerallassie screenshot
  164   Fri Apr 4 17:59:33 2025 Zac , SidDAQ17:58
DAQ stopped with last file in RSA1-2025.04.04.17.58.49.340.tiq

Now the plan is to change one of the analyzers to narrow band recording for longer from the 245 Schotkky. 
  163   Fri Apr 4 17:30:25 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 188Hf72+ setting
  162   Fri Apr 4 17:13:12 2025 Team PleiadesDetectorsPLEIADES detector out
17:12 We moved the PLEIADES detector out, both are outside now (in parking position)
  161   Fri Apr 4 17:10:35 2025 H. Weick, S. LitvinovAcceleratorESR scraper setting
the new scraper setting for good isochronicity but still acceptable intensity losses is:
Done at ~ 15:00 today.
GEEXDS1HA (outside)          =  -8 mm
GEEXDS1HG (ToF-det-aperture) =  20.5 mm
GE01DS3HG                    = -84.2 mm  (fully open is -130 mm)
in addition, a detector pocket is in GE01DD2IG = 1.7 mm
  160   Fri Apr 4 17:04:39 2025 H. Weick, S. LitvinovAcceleratorslits after target, Bio_REM alarm
A Bio-REM detector on the roof of ESR caused an alarm and shut down the whole accelerator.
Too much primary beam going to ESR, noe we avoid it by catching the primary beam at TE4 slits.
The distribution on current grids looks liek in the LISE simulation, we cut at 5mm.
The beam come sin three charge states tehouter ones 82+, 81+ anyway do not make it to ESR, we need to cut also the 80+ at least half.
Then the dose rate on ESR roof is much lower 0.8 uSv/h -> 0.2 uSv/h.
  159   Fri Apr 4 16:59:25 2025 KK BJDAQLassie screen shots
  158   Fri Apr 4 16:24:48 2025 Ruijiu, YuriAnalysisPID of 186Hf
Code used to add up injection data.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/2025.04.04.13.00$ find /data.local/G22-00018_00203/results/analyzers/RSA01 -name "RSA01-2025.04.04.*.tiq_spectrogram.npz" > filelist.txt
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/summed_spectrum$ python npz_addup.py --time-cut 0.14 filelist.txt
  157   Fri Apr 4 16:12:54 2025 JG, IDGeneralpleiades detectors moving
We started moving the pleiades detectors at 16:13 04-04-2025.

We have the inside pocket (GE01DD2IG) at 2mm. 
The outside pocket (GE01DD2AG) cannot be moved by the Device Control program, some problem with the tolerance (error message: outside of tolerance). Need to go in in a short break and check what is wrong.

We will partly scrape the beam.
  156   Fri Apr 4 16:12:14 2025 Team PLEIADESDetectorsInserting both PLEIADES detectors
We are inserting both PLEIADES detectors step-wise, one by one. Main beam should not be affected too long.
  155   Fri Apr 4 16:01:09 2025 ID, MC, KanikaGeneral186Hf running now + Lassie screenshots
Tuning is finished, 186Hf is running. Sharp peaks now.
  154   Fri Apr 4 14:47:29 2025 ID MG BJGeneralLassie screen shots
186Hf screen shots with better resolution
  153   Fri Apr 4 14:01:20 2025 MG, ID,NHGeneralScreen shot
Lassie screen shots 186Hf
  152   Fri Apr 4 11:48:37 2025 MG, NH, IDGeneralsetting change to 186Hf + Lassie screenshots
186Hf, 510MeV/u of 208Pb beam, ecooling not working 
  151   Fri Apr 4 11:44:31 2025 Ragan, Wolfram, Sergey, Zsolt, MagdaGeneral ESR setting change from 188Hf72+ to 186Hf72+
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for 
this fragment is 510 MeV/u.Brho = 7.86166 Tm.
  150   Fri Apr 4 11:15:05 2025 Ragan, Wolfram, Sergey, ZsoltGeneralElectron Cooler
No additional HV. So, have to proceed without the cooler. 
Spare Power supply did not work either, we will not be able to use the cooler for the rest of the experiment
  149   Fri Apr 4 11:00:35 2025 Ragan, Wolfram, Sergey, ZsoltGeneralElectron Cooler
Electron cooler anode voltage needs a repair which might take 20-30 mins. If it takes longer, we'll proceed without a cooler curve measurement. 
  148   Fri Apr 4 10:36:40 2025 Ragan, Wolfram, Sergey, ZsoltGeneralESR setting change from 188Hf72+ to 186Hf72+
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for the primary beam transmission check is 528 MeV/u.
  147   Fri Apr 4 09:45:02 2025 Ragan, Wolfram, SergeyGeneralElectron Cooler
Regina, Jan, and Markus are in the ESR to check the electron cooler.
  146   Fri Apr 4 09:26:11 2025 Nic, MagdaGeneralstop
STOP RSA for beam tuning
  145   Fri Apr 4 08:53:30 2025 Nic, Magda, Ragan, JanGeneralBeam Break
Intensity dropped a lot, ion source fix ongoing
ESR access for 5-10 mins to restart PLEIADES DAQ
FRS has also taken beam again, so ESR is sharing

08:55: ESR closed and takes beam again
  144   Fri Apr 4 07:51:58 2025 Nic, MagdaGeneralScreenshots
  143   Fri Apr 4 06:45:12 2025 zhang, zhouGeneralscreenshot
  142   Fri Apr 4 05:45:37 2025 zhang, zhouGeneralscreenshot
  141   Fri Apr 4 04:45:39 2025 zhang, zhouGeneralscreenshot
  140   Fri Apr 4 03:44:59 2025 zhang, zhouGeneralscreenshot
  139   Fri Apr 4 02:51:30 2025 zhang, zhouGeneralscreenshot
  138   Fri Apr 4 01:41:48 2025 Zhang, ZhouGeneralScreenshots
  137   Fri Apr 4 01:12:03 2025 ShahabAnalysisNPZ add up script
Since there are many NPZ summer scripts around, I thought I would also share mine. This one takes advantage of the power of filelists and has a progress bar. Creating file lists gives you more control over the range of analyzed data, for example, the command:

find /data.local/G22-00018_00203/results/analyzers/RSA02 -name "RSA02-2025.04.04.01.??.??.???.tiq_spectrogram.npz" > filelist.txt

makes a file list of everything file that was produced during the second hour of the morning of the April 4th. You can fine tune the wildcards according to the time range you are interested in.


then just call the script by:

python npz_addup.py filelist.txt

you can also provide time cuts, like this:

python npz_addup.py --time-cut 0.14 filelist.txt

which will cut away first 0.14 seconds of the spectrogram. Without time cuts, it will do over the whole range.


It creates 4 type of files:

summed_spectrum.npz --> for use with RionID for PID
summed_spectrogram.npz --> for general use / analysis
summed_spectrum.png --> for general view
summed_spectrogram.png --> for detailed view

if time-cut is provided, the filenames will have a "_time_cut" suffix at the end.


Here is the link to the script:

https://github.com/xaratustrah/e0018_e0203_scripts/blob/main/npz_addup.py

examples are in attachment:
  136   Fri Apr 4 00:46:18 2025 Zhang, ZhouGeneralScreenshots
  135   Thu Apr 3 23:42:05 2025 Zhang, ZhouGeneralScreenshots
  134   Thu Apr 3 23:23:20 2025 Zhang Min, Zhou XuAcceleratorBeam injection change
The SIS operator says that FRS doesn't need beam now, ESR will receive the full SIS beam extraction every 3 secs overnight. All the secondary beams are injected into ESR from now on.
  133   Thu Apr 3 22:25:49 2025 Usama, KathrinGeneralScreenshots
  132   Thu Apr 3 21:25:40 2025 Usama, KathrinGeneralScreenshots
  131   Thu Apr 3 20:01:58 2025 Usama, KathrinGeneralScreenshots
  130   Thu Apr 3 18:53:02 2025 Usama, KathrinGeneralScreenshots
  129   Thu Apr 3 18:01:49 2025 Ruijiu, CarloAnalysisIdentification of 188Hf
  128   Thu Apr 3 17:49:57 2025 Usama, KathrinGeneralScreenshots
  127   Thu Apr 3 17:38:47 2025 Shahab, Zac, Carlo, Esther and many moreDAQRSAs run again!
first file name RSA01....17.38 onwards.
  126   Thu Apr 3 17:01:07 2025 CJ Griffin, M Cockshutt, G LeckenbyGeneralMoving PLEIADES detectors in
The inner PLEIADES is moved into position close to the beam.
Device control for the outside pocket is not currently working so that pocket remains in its outward position.

NTCAP/Schottky data acquisition stopped during pocket position tests.

Inner detector (x86l-124 BGO)
Device: GE01DD2IG
Position: +20 mm
Scraping beam: not possible

Outer detector (x86l-131 GAGG)
Device: GE01DD2AG
Position: -127 mm
Scraping beam: 
  125   Thu Apr 3 16:44:18 2025 Usama, KathrinGeneralScreenshots
  124   Thu Apr 3 15:57:16 2025 Shahab, Yue, Zac, EstherDAQData acquisitions running
All data acquisitions (both RSAs and NTCAP) are now running.
  123   Thu Apr 3 15:55:04 2025 Shahab, Yue, EstherCalibrationSchottky settings
Settings similar to the 2-photon experiment.

Central frequency: 411.742243 MHz (based on Ruijius identification for 188Hf72+)
  122   Thu Apr 3 15:21:42 2025 CJGGeneralPLEIADES shift instructions
PLEIADES shift instructions available at:
https://docs.google.com/document/d/19b4wyugC3OpVAjwt1ONM9u8EYdMJsBpL7GVNzoziv0M/edit?usp=sharing

Leakage current tracking:
https://docs.google.com/spreadsheets/d/1Gt1tFHwn4XFrJ5_-nQvTi635UD0aHgN6gCdXDTHQdkI/edit?gid=299353113#gid=299353113

Leakage currents should be documented every ~1-2 hours while the detectors are biased.
  121   Thu Apr 3 13:36:17 2025 Ruijiu,Yuri, Wolfram,ZsoltAnalysis188Hf identification
  120   Thu Apr 3 13:32:42 2025 CN, IDGeneralScreenshots
  119   Thu Apr 3 11:51:00 2025 CN, IDDAQRSA started for 188Hf ESR tuning
Started both RSAs for the tuning of the ESR to 188Hf. Both pockets are in parking position OUTSIDE.
  118   Thu Apr 3 10:07:34 2025 CN, ZP, CJG, MCGeneralScreenshots
  117   Thu Apr 3 09:53:02 2025 Ruijiu Chen,WolframAnalysisGood injection ratio
Currently, we only use 37% of the injections in our data analysis. However, 63% of the injections have a height below 100, and these may include 
single ion injections. We need to visually inspect these injections to identify the single ion injections.
  116   Thu Apr 3 09:43:14 2025 AllAcceleratorStop 194Pb, switch to 208Pb82+
The repair of SIS electron cooler power supplies

In the meantime we received a few injections and confirmed that 194Pb setting is still as it was before entering into the ESR

Now we change to 208Pb82+ to do several ESR accelerator tests

Esis = 517 MeV/u
Change the beamline to 208 Pb 82+ and the ESR to 208 b 82+ and NO other changes
  115   Thu Apr 3 09:34:42 2025 IDGeneralFinished in the ESR as of 9:05
We had stopped the RSAs at 8:00 (call for restart)
Time stamp computer stopped and started at 9:35
  114   Thu Apr 3 08:02:04 2025 Team PLEIADES (JG, ID, CJG, MC)DetectorsEntering ESR for PLEIADES
We are going to enter the ESR to check on the PLEIADES pocket detectors and install a nitrogen cooling.
  113   Thu Apr 3 07:59:09 2025 ZP, CN, IDGeneralScreenshots
Screenshots before opening ESR.
  112   Thu Apr 3 06:56:31 2025 JEL, ZNRunsScreenshots
  111   Thu Apr 3 06:33:08 2025 Zac, JohanGeneralBeam lost at 06:27, returned at 06:34
Spike in beam intensity at 06:27 (5x usual intensity) and then beam is lost. HKR says it's a problem with the magnet's power supply. Once the beam returned, the peaks are shifted to the left but are slowly shifting back into position.
  110   Thu Apr 3 06:16:32 2025 JEL, ZNGeneralScreenshots
Stable since last entry
  109   Thu Apr 3 05:11:37 2025 Zac, JohanGeneralBeam lost at 05:07, returned at 05:14
  108   Thu Apr 3 03:48:40 2025 JEL, ZNRunsScreenshots
The peaks in the analyzer are slowly shifting back to the original position. 
Note that a quadrupole was the cause of the issue 45 mins ago and it was cycled.  Might be relevant...
  107   Thu Apr 3 02:59:15 2025 JEL, ZNRunsScreenshot, beam received, baem lost, beam back again
Beam is back for 10 mins-

The peaks on the analyzer appear shifted to the right.

As I write this the beam disappeared again.... 02.59

and back again at 03.08
  106   Thu Apr 3 02:52:27 2025 Zac, JohanGeneralBeam is back at 02:52
  105   Thu Apr 3 02:01:29 2025 Zac, JohanGeneralQuadrupole issues
HKR has called someone to fix the quadrupole, they think it will take about an hour.
  104   Thu Apr 3 01:56:57 2025 Zac, JohanGeneralProblems with one of the quadrupoles
Since around 01:45 we get spills but see nothing on analysers. HKR says there is a problem with one of the quadrupoles; they are working on it.
  103   Thu Apr 3 01:29:49 2025 Zac, JohanGeneralBeam is back at 01:27
  102   Thu Apr 3 01:19:44 2025 Zac, JohanGeneralBeam fluctuations
Beam gone again between 01:14 and 01:18, then again at 01:19. HKR says there are problems with the source.
  101   Thu Apr 3 01:14:16 2025 Zac, JohanGeneralBeam is back at 01:12
  100   Thu Apr 3 00:49:00 2025 Zac, JohanGeneralBeam lost at 00:46
  99   Wed Apr 2 23:40:23 2025 JEL, ZNGeneralScreenshots taken just as beam came back
We are seeing spills being received but no peaks are seen in the analyzers. 

We are seeing several intermittent losses of beam. Awaiting action to see if it stabilizes.


23.51 Beam is back and we see the nice spectrum in the analyzer.
  98   Wed Apr 2 23:33:43 2025 ZacAcceleratorBeam is gone at 23:29
  97   Wed Apr 2 23:27:35 2025 Zac, JohanAcceleratorBeam is back 23:25
  96   Wed Apr 2 23:15:52 2025 Zac, JohanAcceleratorNo injections from SIS
Night shift starts with no injections from SIS! We still have triggers; we called HKR and are waiting for response.
  95   Wed Apr 2 22:47:25 2025 ID, HA (Radio Shahab as background)GeneralLassie and Schottky TV screentshots
We managed to take some screenshots while Shahab harrassed us with AI-created "RammstAIn" music... happy to end my shift now!
  94   Wed Apr 2 21:22:41 2025 ID, HAGeneralLassie Come-Home Screenshots (wuff!)
(Who let the dog out?)
Sharing with FRS 6:1 since a while now.
  93   Wed Apr 2 20:57:34 2025 ShahabDetectors10GB cables for the DAQ rack
We have been working together with IT on the speed of data transfer: with the new 10 GB interface we can now transfer data from NAS to Lustre with 400MB/s. From NAS to GPU Computer up to 700MB/s. All cables around the rack are now 10GB capable.
  92   Wed Apr 2 20:15:29 2025 ID, HAGeneralLassie screenshots + Schottky TV
Screeeeeeeenshooooots!
  91   Wed Apr 2 19:13:50 2025 ID, HAGeneralLassie screenshots and Schottky screenshot
Looks a bit more regular now (FRS people having dinner???)
  90   Wed Apr 2 18:31:52 2025 IDGeneralFYI for morning shifts Thu
The PLEIADES team (pocket detectors) has discussed with Wolfram to get access to the ESR tomorrow (Thu) morning ~8:00 to check their detectors and install a dry N2 flow connection. This might take about 1h. Iris (or Jan) will call the HKR to get the RP shift for the transport of the N2 bottle into the ESR. Morning shift will be informed accordingly when we are onsite, just keep running (keep running...keep running...keep running) until we get access.
  89   Wed Apr 2 18:22:30 2025 IDGeneralSpill cycle distribution
The spill cycle distributions is absolutely nuts since beginning of the shift. On the positive side: we got a lot of spills since FRS did not take many, so I think we got more than our parasitic 1:10 share...
  88   Wed Apr 2 18:15:06 2025 ID, HA, MWGeneralLassie screenshots
  87   Wed Apr 2 18:13:20 2025 ID, HAGeneralRSA spectra
  86   Wed Apr 2 17:46:12 2025 Ruijiu, Wolfram, Xinliang, WangqianAnalysisThe spectrum of 194Pb82+ vs 184Pt78+
In summary, the statistical results collected between 5:00 and 12:00 AM on April 2, 2025. For each injection, we calculate the frequency mean value 
(f_mean) and the peak height (P) of 194Pb ions for frames with t > 0.14 s, correct each injection’s frequency by subtracting f_mean, and only sum 
the 
spectra from injections with P > 100; moreover, by comparing the 194Pb82+ spectrum with that of 184Pt78+—whose isomer at 1.8 MeV (T1/2 = 1 ms) is 
clearly visible—the setup is demonstrated to be suitable for detecting an isomer with a lifetime of about 1 ms.
===================================================================
How to dod analysis and plot this result:
1. Add up injections and create accumulated spectrum.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data$ sh generate_data.sh /data.local/G22-
00018_00203/results/analyzers/RSA01 RSA01- 
'*.tiq_spectrogram.npz' 2025.04.02.05.00.00.000 2025.04.02.12.00.00.000 0.001 408.59e6 408.62e6 0.1 1

After run this command, you will create the accumulated spectrum under the folder with time stamp of start time and stop time.

2. Download the code "plot_fft.cxx" and plot the spectrum with following command:
...2025.04.02.05.00.00.000_2025.04.02.12.00.00.000$ root
   ------------------------------------------------------------------
  | Welcome to ROOT 6.32.10                        https://root.cern |
  | (c) 1995-2024, The ROOT Team; conception: R. Brun, F. Rademakers |
  | Built for linuxx8664gcc on Feb 12 2025, 01:50:41                 |
  | From tags/6-32-10@6-32-10                                        |
  | With                                                             |
  | Try '.help'/'.?', '.demo', '.license', '.credits', '.quit'/'.q'  |
   ------------------------------------------------------------------

root [0] .L plot_fft.cxx
root [1] plot_fft("2025.4.2 5:00~12:00",411.14e6,411.18e6,0,100)
  85   Wed Apr 2 17:06:45 2025 ID, HA et alGeneralLassie screenshots
  84   Wed Apr 2 16:28:14 2025 SS, ID, HA etcDAQNTCAP stop/start
NTCAP was stopped and restarted.
  83   Wed Apr 2 15:46:24 2025 ID, HA,MWGeneralBeam back in ESR,
beam is back, we started DAQ again. All files created after 15:45 should be good from now on.
  82   Wed Apr 2 15:07:52 2025 Michael, Alex, MaeveAcceleratorStill not a good beam in the ESR
The (power supply of) SIS kicker magnet has been repaired and the beam has been restored from about 14:20.
But, the Schottky spectrum in the ESR looked pretty bad, so the measurement can not be restarted. 
The accelerator experts are currently looking into this problem.
  81   Wed Apr 2 13:35:17 2025 Michael, Alex, MaeveDAQRSAs data taking
Since there will be no beam for about one hour, the data taking in RSAs has been stopped.
  80   Wed Apr 2 13:27:52 2025 Michael, Alex, MaeveAcceleratorNo beam in the ESR
There is no beam in the ESR since couple of minutes. According to the info from HKR, the experts started to repair the magnets (power supplies) used for extraction and transfer of the beam from SIS to ESR. It is estimated to take about 1 hour.
  79   Wed Apr 2 12:58:15 2025 Ruijiu, WolframAnalysisfrequency drift
  78   Wed Apr 2 12:13:57 2025 Michael, AlexAcceleratorSome empty injections triggered while beam patterns are changed
Operators seem to play with spill cycles, we get every 1:1 shot, then 1:10 again. During this, we noticed a few "empty injections" beeing triggered in the RSAs. They light up green, but spectrum is flat. Then it returns to normal operation again.
  77   Wed Apr 2 11:09:42 2025 Michael, AlexAcceleratorThe beam is back in the ESR
We have the beam again the ESR since around 11:00.
The Schottky spectra look the same as before.
The ESR experts could not exactly identify the problem which caused this loss of the beam.
  76   Wed Apr 2 10:55:16 2025 Michael, Alex, WolframAcceleratorNo beam in the ESR
Since few minutes do not see any beam in the ESR (on RSAs). There is beam in SIS and injection requests from the ESR seem to be there as well.
  75   Wed Apr 2 10:31:15 2025 Michael, AlexAcceleratorThe beam is back from 10:10
  74   Wed Apr 2 10:05:06 2025 Michael, Alex, YuriAcceleratorNo beam since 09:59
The SIS kicker has failed again.
  73   Wed Apr 2 10:02:40 2025 Sergey + YuriAcceleratorESR Timeout
At around 9:40, ESR timeout changed from 10 s to 30 s
Triggering only on real injections.
Before that, every second injection was not real but the old one. They can be identified since they should have no "kicker" disturbance.
  72   Wed Apr 2 09:28:59 2025 Michael, AlexGeneralEmpty injections in the ESR
Since the FRS started to take the beam again, the ESR gets 1/10 shots from SIS. But, the ESR seems to request about twice more frequently the beam from SIS which means that every second shot in the ESR is empty (it contains the remaining beam from the previous injection). This also applies to the data stored by RSAs because they also (seem to) trigger each time the ESR requests the beam.
  71   Wed Apr 2 08:47:27 2025 Michael, AlexGeneralThe beam is back
The beam is back. But, the experts have found a problem with one of the modules of the SIS kicker magnet. And, currently they have disabled this module. This fixed the problem. However, since the kicker system is not running with full power, it is not clear by how much this can affect the extracted beam intensity for the ESR. Therefore,  the ESR experts have been called and they will look at the injected beam intensity in the ring, in order to know if its still the same as before disabling the module. 
The experts will discuss at the upcoming meeting how to proceed with the damaged module, i.e. when to repair it.
In addition, the FRS started to take the beam now (again) which means that we will be getting less pulses from SIS as compared to the previous night.
  70   Wed Apr 2 08:04:47 2025 Michael, AlexGeneralNo beam
The SIS kicker has failed again at 08:01.
Since this has happened already few times, the experts from the on-call duty service are now looking at the problem.
  69   Wed Apr 2 07:41:10 2025 Michael, AlexGeneralFrequency shift in Schottky
After the beam  was restored at 07:25, we think that the frequency peak in the 244 MHz RSA2 has jumped again (closer to the center). 
Previous to that, during the longer break in the previous night, the peak jumped to higher frequencies.
  68   Wed Apr 2 07:39:41 2025 Michael, AlexGeneralThe beam is back at 07:35
  67   Wed Apr 2 07:33:59 2025 Michael, AlexGeneralBeam gone again
7:29, beam gone again, operators say they need another 5 minutes.
  66   Wed Apr 2 07:25:15 2025 Carlo, Chris, Alex, Michael GeneralBeam back
07:20  we have beam back.
  65   Wed Apr 2 07:16:33 2025 Carlo, Chris, Alex, MichaelDAQESR not requesting
7:05 ESR not requesting new pulses from the SIS. 
Operators are trying to fix the problem.

7:20 eam is back
  64   Wed Apr 2 05:48:31 2025 Chris, Carlo, ZacGeneralBeam returned
Beam was returned to the ESR at 05:11.

HKR said there had been some problem with one of the dipoles and in order to restore it a power supply had to be reset, which took some time.

05:41 data are back in the RSAs. Files that contain data from:
RSA01-2025.04.02.05.41.14.938.tiq_spectrogram.npz
to:
RSA01-2025.04.02.06.24.01.530.tiq_spectrogram.npz


06:24 data not visible again, only noise.

06:43 data are ack in the RSAs. Files that contain data from:
RSA01-2025.04.02.06.43.43.580.tiq_spectrogram.npz
  63   Wed Apr 2 04:59:50 2025 Zac, Chris, CarloGeneralReceiving injections but not seeing anything on RSAs
Starting at around 04:09 we don't see anything on RSAs. RSAs are still triggering and writing files, but only see noise. Lassie indicates beam current in the ESR

We called HKR, they said they will investigate, awaiting response.


last file that contains data: RSA01-2025.04.02.04.09.27.044.tiq_spectrogram.npz
file from which only noise is contained: RSA01-2025.04.02.04.09.31.905.tiq_spectrogram.npz 

At 04:09: drop of beam in the SIS as shown in screenshots.


For a minute there were still good data. Files from:
RSA01-2025.04.02.04.13.44.629.tiq_spectrogram.npz
to:
RSA01-2025.04.02.04.14.47.805.tiq_spectrogram.npz



05:30 update from HKR: There is a problem with the ESR main power supply. We have to wait.
  62   Wed Apr 2 04:33:57 2025 Carlo, Zac, ChrisDAQScreenshots Lassie
screenshots of Lassie
  61   Wed Apr 2 02:51:31 2025 Carlo, Zac, ChrisDAQBeam is back
02:44 beam is back
  60   Wed Apr 2 01:46:52 2025 Chris, Carlo, ZacGeneralBeam loss
HKR just called to say a power supply to the SIS18 extraction kicker has failed.
The service person has been called and is expected to take ~1h to arrive and approx. ~2h to carry out the repair.
  59   Wed Apr 2 00:59:43 2025 Zac, Carlo, ChrisAcceleratorLost the beam
Beam was lost from 00:44 until 00:59
  58   Wed Apr 2 00:08:57 2025 Ruijiu Chen,ShahabAnalysisthe peak corresponding to 194Pb⁸²⁺ was mixed with signals from some unknown ions.
I examined the spectrum of 194Pb at the 211 harmonic. It was observed that the peak corresponding to 194Pb82+ was mixed with signals 
from some unknown ions. Consequently, we switched to the 212 harmonic, where the frequency of 194Pb82 was measured at 410.5385024.
  57   Tue Apr 1 23:56:18 2025 Shahab, Carlo, Zac, Yue, MichaelDAQChange of RSA01 settings for new harmonic=212.
23:55 stop the RSAs. 

410:
last file from previous setting (harmonic=211): 2025.04.01.23.55.21.712.
new plunger position for 410 cavity: 33.5 inside and outside.
new center frequency: 410535000 Hz.

245:
harmonic didn't change, still 126.
adjusted center frequency to 243997000 Hz.

00:31 restart the RSAs.
new files from: 2025.04.02.00.31.11.796.
  56   Tue Apr 1 23:23:18 2025 C GriffinGeneralPLEIADES removed
Leakage currents were steadily increasing in the PLEIADES detectors so we decided to stop taking data, move both the detectors back and turn off bias.
  55   Tue Apr 1 23:07:15 2025 ShahabDAQshort interruption of queqiao script for RSAs
has been restored.
  54   Tue Apr 1 22:53:59 2025 EstherGeneralLassie exports
  53   Tue Apr 1 22:05:24 2025 Ruijiu Analysisanalysis result
This is a preliminary result during 4:00-19:00 April 1st 2025. 
I correct the frequency drift of 194Pb82+ ions injection by injection.

I have analyzed all injection data during 4:00-19:00 and calculated the frequency of 194Pb82+ for each injection. This is the frequency of 194Pb82+ as 
a function of time. You can clearly see that the frequency of 194Pb82+ was drifted from 408.603 to 408.600 MHz. The variation of frequency is about 
3kHz.
  52   Tue Apr 1 22:03:07 2025 Jeroen, Zac, Esther, Shahab, WolframDAQOptimisation of settings
Estimation of potential gain by changing. Files from this points are going to rubbish. Potential gains are c. 20% 

22:04: The current acquisition window is recording for 2.9 s. And is not recording for 3.9 s. We are running currently with a spill cycle of 5s every repetition.

22:22 The spill cycle between each injection was changed to 4->3->2s progressively and FRS also stopped taking spills so we settled on 2s spill request.

In the morning the spill request has to be changed back to 5s when the FRS goes back into operation.

new file with the setting is

RSA01-2025.04.01.22.19.06.761.tiq

[analysis]
nframes = 190
lframes = 65536
navg = 1
  51   Tue Apr 1 21:05:20 2025 Jeroen, Zac, Esther, Shahab, WolframDAQChange of settings for shorter acq. window
> Acquisition stopped at 20:36. 
> 
> First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq
> 
> Last file from this setting: RSA01-2025.04.01.20.36.54.257.tiq
> 
> acq. length changed to 500 ms
> 
> acq bw changed to 50 MHz
> 
> ==> 12 MSamples
> 
> Trigger window condition set to 50%.
> 
> First file from this setting: RSA01-2025.04.01.20.45.40.053.tiq
> 
> Analysis setting the the frame length 2^16 and frame number = 190.

Last file from previous setting: RSA01-2025.04.01.21.06.30.580.tiq

Changed the RSA01,02 to 50 MSamples/s (20nsec/sample) for 500.00 ms acq. length, 25 MHz acq. BW, 33% trigger position.

First good file from this time: 21:37 04.01.2025 -- RSA01-2025.04.01.21.37.13.721.tiq
  50   Tue Apr 1 20:37:04 2025 JeroenDAQChange of settings for shorter acq. window
Acquisition stopped at 20:36. 

First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq

Last file from this setting: RSA01-2025.04.01.20.36.54.257.tiq

acq. length changed to 500 ms

acq bw changed to 50 MHz

==> 12 MSamples

Trigger window condition set to 50%.

First file from this setting: RSA01-2025.04.01.20.45.40.053.tiq

Analysis setting the the frame length 2^16 and frame number = 190.
  49   Tue Apr 1 20:19:23 2025 Jeroen, Zac, EstherAcceleratorBeam fell out
> > No beam from 19:57:41.
> 
> Beam back from 20:02
  48   Tue Apr 1 20:02:19 2025 Jeroen, Zac, EstherAcceleratorBeam fell out
> No beam from 19:57:41.

Beam back from 20:02
  47   Tue Apr 1 20:00:14 2025 Jeroen, Zac, EstherAcceleratorBeam fell out
No beam from 19:57:41.
  46   Tue Apr 1 17:08:13 2025 JG, ID, MC, CGDetectorspleiades in position
The pleiades detectors are now moved into a position which does not disturb the stored beam. 

inner detector: BGO
device: GE01DD2IG 
position: +20mm
scraping beam: not possible

outer detector: GAGG
device: GE01DD2AG
position: -55mm
scraping beam at: -45mm

These positions are fixed, i.e. not moving automatically.
  45   Tue Apr 1 16:47:32 2025 Ruijiu, Jan, ShahabAnalysisThe frequency of 194Pb82+ is changed to 408.600 MHz
  44   Tue Apr 1 16:44:32 2025 Jeroen, EstherGeneralNo SIS beam since 14:35
Beam resumed at 16:40. 
  43   Tue Apr 1 15:38:50 2025 ruijiu chenAnalysisfrequency drift
  42   Tue Apr 1 15:32:59 2025 ZacDAQNTCAP Restarted
NTCAP Has been restarted (we restart every day around 15:00 so data goes in a new folder)
  41   Tue Apr 1 14:54:24 2025 allGeneralNo SIS beam since 14:35
  40   Tue Apr 1 14:25:21 2025 ruijiu AnalysisThe frequency of 194Pb82+ has been changed from 408.606MHz to 408.602MHy during last 12 hours
The following images display the frequency spectrum at the start of every hour from 3:00 to 14:00.
  39   Tue Apr 1 14:23:01 2025 JGGeneralPleiades pocket position tests
We started playing with the detector pockets of the pleiades arrays at 14:23 01.04.2025.

This might disturb the beam sometimes.

The beam is lost in SIS at 14:35. 

Beam came back at 16:40, we continued playing with pleiades positions until 17:14.
  38   Tue Apr 1 14:17:07 2025 RuijiuAnalysisPID of 194Pb82+ 2025.04.01.14.13.07
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.14.13.07.068.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408602000"
reload_data = true
nions = "100"
  37   Tue Apr 1 14:02:23 2025 Jelena B, SiddharthGeneralLassie
  36   Tue Apr 1 12:58:27 2025 Jelena B, SiddharthGeneralLassie
  35   Tue Apr 1 11:47:14 2025 Jelena B, SiddharthGeneralLassie 2025-04-01_11-46-35-517_tcl1064.png
  34   Tue Apr 1 10:34:20 2025 Jelena B, SiddharthGeneralResolved issue with SIS18
Beam is back with some fluctuations.
We did not have beam from 9:34 until 10:08, around 35 minutes. 
  33   Tue Apr 1 10:03:56 2025 Jelena B, SiddharthGeneralTechnical issue with SIS18
From HKR info: there is a technical issue with SIS18 and we will have no beam for next 25 minutes. 
  32   Tue Apr 1 08:36:25 2025 Jelena B, SiddharthGeneralLassie 2025-04-01_08-37-32-155_tcl1064.png
  31   Tue Apr 1 06:53:51 2025 Jelena B,SiddharthGeneralLassie Monitor
  30   Tue Apr 1 06:31:46 2025 MichaelGeneralLassie Monitor 2025-04-01_06-31-10-211_tcl1064.png
  29   Tue Apr 1 05:58:51 2025 MichaelGeneralLassie Monitor 2025-04-01_05-58-09-122_tcl1064.png
  28   Tue Apr 1 05:29:45 2025 MichaelGeneralLassie Monitor 2025-04-01_05-29-01-845_tcl1064.png
  27   Tue Apr 1 04:59:14 2025 MichaelGeneralLassie Monitor 2025-04-01_04-58-31-351_tcl1064.png
  26   Tue Apr 1 04:27:10 2025 MichaelGeneralLassie Monitor 2025-04-01_04-25-53-171_tcl1064.png
  25   Tue Apr 1 03:55:59 2025 MichaelGeneralLassie Monitor 2025-04-01_03-55-21-183_tcl1064.png
  24   Tue Apr 1 03:52:56 2025 Shahab, Michael, Yue, Zac, CarloDAQgood files
all settings are done.
any files coming after this one is good:

RSA01-2025.04.01.03.52.59.247.tiq
  23   Tue Apr 1 03:50:12 2025 Shahab, Yue, Carlo, Zac, Esther, MichaelDAQTuners of the both cavities set
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm
  22   Tue Apr 1 03:27:44 2025 MichaelGeneralLassie Monitor 2025-04-01_03-22-05-395_tcl1064.png
  21   Tue Apr 1 02:55:06 2025 Shahab, Michael, Yue, Zac, CarloDAQnew RSA recording
anything from RSA01-2025.04.01.02.54.25.976.tiq onwards is good data

recording parameters:

5 MHz with 6.25 MSPS, 2.5 seconds, analyzer span 100 khz, trigger at 5%

All analyzer times are now set to summer time
file time stamps are correct

settings are in the attached pictures.
  20   Tue Apr 1 02:37:28 2025 H. Weick, S. LitvinovAcceleratorIsoc-setting +scrapers
First a setting with orbit bump for injection on central orbit was tried.
- quadrupoles tuned and scrapers optimized

Then back to an ESR setting without this bump like last year.
- again quadrupoles tuned and scrapers optimized
This gave a good resolution in which the isomer should be resolved.

Just after this was achieved all resolution was lost.
Making the input for ESR setting again recovered it, now with slightly different scrapers.

Quads: K'L Q3D / Q6D = -0.3603263
Sext: K''L GE01KS2 = -0.14
           GE01KS3 =  0.05

scrapers: GEEXDS1HA =  -5 mm
          GE01DS3HG = -70 mm 

Details see paper scans below.
  19   Tue Apr 1 02:20:36 2025 ruijiuAnalysischange back the frequency of 194Pb82
frequency of 194Pb82+ at 211 408606000
frequency of 194Pb82+ at 126 244001000
  18   Tue Apr 1 02:03:33 2025 ruijiuAnalysisThe frequency of 194Pb82+ has been changed from 408.522 MHz to 408.637 MHz
this is the new setting after we lost the old one.


datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.00.55.55.572.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408637000"
reload_data = true
nions = "100"
  17   Tue Apr 1 02:01:06 2025 Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, MichaelAcceleratorSettings lost
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned.
  16   Mon Mar 31 23:34:58 2025 ruijiu, shahab, yuri, wolfram, sergeyAnalysisidentificaton of 194Pb82+
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.03.31.22.18.16.965.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.4"
harmonics = "212"
refion = "194Pb+82"
circumference = "108.34"
mode = "Bρ"
value = "7.196596"
reload_data = true
nions = "100"
  15   Mon Mar 31 22:35:36 2025 ruijiu ChenAnalysisIdentification of 194Pb82
  14   Mon Mar 31 22:13:04 2025 Shahab, Yue, Carlo, Zac, EstherRunsPID continued
continuing PID with better / higher resolution:

RSA01-2025.03.31.21.10.54.758.tiq_spectrum.npz
...
RSA01-2025.03.31.21.12.29.106.tiq_spectrum.npz

trying to do PID....
  13   Mon Mar 31 22:03:56 2025 Shahab, Yue, Carlo, Zac, EstherRunsPID
trying to do PID with some injections:

RSAs are still on winter time. they show summer time but files have winter time.

data used for PID is range from:

RSA01-2025.03.31.20.21.13.217.tiq_spectrum.npz
...
RSA01-2025.03.31.20.53.06.492.tiq_spectrum.npz

gamma_t = 1.4

but files are not so good.
  12   Mon Mar 31 20:53:02 2025 Shahab, Carlo, Zac, Esther, MichaelDAQDAQ start
20:28 started NTCAP
started queqiao file transfer for RSAs only
started analyzer looper for RSAs

 
  11   Mon Mar 31 20:42:38 2025 H. Weick, S. LitvinovAcceleratorfragment setting, E-SIS
~ 20:00 changed E-SIS to 524.0 MeV/u to get 194Pb at the Brho of the primary beam before (=7.2008 Tm).
which corresponds to gamma = 1.400 for 194Pb82+. 
Before it was E-SIS = 480.5 MeV/u after Be-1839 mg/m^2 target Brho = 7.2014 Tm.
Keep target and beamlines and ESR the same, only SIS and TE-line before target is changed.
  10   Mon Mar 31 17:46:21 2025 EstherDAQNTCAP scaler assignment
The setup contains two NI-6612 I/O cards with BNC-2121 connector accessories that provide eight inputs each for TTL scaler signals.
Important: When connecting scaler signals make sure that they are TTL (not NIM)!

Additionally, there is the possibility to assign data streams (eg clocks) from other modules in the NI chassis to scaler channels.
Below you find the assignment of the channels on the software side, including the internal clocks. This is important when analysing the .tmds files.

ChannelInputComment
010 MHz clockexternal (from NI 6674T timing module)
1DC trafoion current in ESR
2injection triggerfrom Genesys (IO2 on sddsc221)
3U-coolercooler voltage
4I-coolercooler electron current
5P-gunpressure at e-cooler
6100 kHz clockinternal
720 MHz clockinternal
8software triggerfrom Detectomer
9PLEIADES outside
9PLEIADES inside
  9   Mon Mar 31 16:53:03 2025 ShahabDAQstop and delete NTCAP data from Weekend test
stop and delete NTCAP data from Weekend test

for now the NAS data2 bank has been flushed to make sure good operation for today's beam.
we have now 35 TB space on bank 2.

the recording will be done on the bank2 of the NAS.

There are still some junk data on bank1, which we will remove later.
  8   Mon Mar 31 16:05:48 2025 ruijiu, shahab, yuyue, zac, carlo, erstherAnalysischeck the trigger signal in the scaler data of NTCAP
1. convert copy a tdms file into the folder:
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ cp /mnt/ntcap-data2/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-
48-51/0000216.sc.tdms ./
2. convert the tdms file into root file.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ /data.local/G22-
00018_00203/scripts/OnlineDataAnalysisSystem/iqt7/convert_iqt_sc -i 0000216.sc.tdms  -o ./
3. plot the result.
picture 1,2: trigger vs time
picture 3: solfware trigger vs time
  7   Mon Mar 31 14:59:18 2025 ruijiuAnalysisrun rionidgui program at HKR
At HKR, there is a Windows computer equipped with X2go software, which allows users to log in to the GPU computer. The login process is as follows: [login steps detailed below]. Once you 
have successfully logged into the GPU computer, you can run the rionid program to identify ions at HKR.
  6   Mon Mar 31 10:46:43 2025 Ruijiu ChenAnalysisThis program is used to combine spectrum which is recored by RSA into one spectrum.
This program is used to combine spectrum of many injections into one spectrum.

Example of usage:

(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data$ bash generate_data.sh /data.local/G22-00018_00203/results/analyzers/RSA01 RSA01- 
'*.tiq_spectrogram.npz' 2025.04.01.04.00.00.000 2025.04.01.19.00.00.000 0.001 408590000 408620000 0.3
  5   Fri Mar 28 22:20:47 2025 Sergey, ShahabGeneralPattern
the ACC pattern for both experiments.
  4   Fri Mar 28 19:42:20 2025 Ruijiu ChenAnalysisQueqiao Program for RSA Data
The `queqiao` program used for RSA data analysis is located at:
  
  (pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem_rsa/queqiao

It is currently running in the screen session named:

  OnlineDataAnalysisSystem_rsa

1. Login the server gpuuser@appc256

2. Reattach to the session, use:

  screen -rd OnlineDataAnalysisSystem_rsa

3. Run the program manually, activate the pyroot environment and execute the following command:

  queqiao ../parameters/queqiaosettings_194Pb_rsa.toml

4. Then press "start" botton, the `queqiao` program copies data from:

  /mnt/ntcap-data2/G22-00018_00203/data/analyzers/RSA01
  /mnt/ntcap-data2/G22-00018_00203/data/analyzers/RSA02

to:

  /data.local/G22-00018_00203/data/analyzers/RSA01
  /data.local/G22-00018_00203/data/analyzers/RSA02
  3   Thu Mar 27 17:20:40 2025 Esther, Yue, Carlo, Zac, ShahabDetectorsSetup Genesys
We set up the Genesys. Channel map:

tr0:
IO1: Trigger MBS
IO2: Trigger NTCAP
IO3: None
IO4: Trigger RSA01
IO5: Trigger RSA02

tr1: 
None
  2   Thu Mar 27 09:42:04 2025 Ruijiu ChenSimulationsSimulation Results for 194Pb and 188Hf
Summary:

1.Simulated spectra for 194Pb and 188Hf.
2.The results are attached.
3. For the 188Hf simulation, some nuclides in the fragments are missing from the AME database, causing errors in the LiseReader program.
To fix this, please download the attached reader.py file and replace your local file at lisereader-main\lisereader\reader.py.
After replacing the file, recompile the program. Once recompiled, you should be able to simulate the 188Hf spectrum without issues.
  1   Mon Mar 24 14:42:33 2025 Jan GloriusCollaborationProposals
Attached are the proposals submitted to and approved by G-PAC.