80
Mon Mar 30 07:02:15 2020
tino
Runs
Second measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA
beam: 206Pb81+
41
Sat Mar 28 16:12:25 2020
ruijiu, ragan
DAQ
enter ESR and turn on the HV crate.
15
Tue Feb 25 15:48:31 2020
ruijiu chen
DAQ
Important folders of e121 eperiments:
1. slow control:
1.1. program file:
litv-exp@ringpi:~/epics/mrcc_ioc/db $
16
Tue Feb 25 15:49:58 2020
ruijiu chen
DAQ
changing scaling factor.
How to change scaling factor?
The parameters is in f_user.c file:
1. open the f_user.C with emacs :
99
Mon Mar 30 14:48:02 2020
ruijiu and Tino
Detectors
The leakcurrent of SiPad is over the setting limit.
Because the
leakcurrent of
6 Sipads is
100
Mon Mar 30 15:03:58 2020
ruijiu Tino, Yuri, Lasoro, Nik and Uli
Detectors
the gas bottle is empty.
The gas bottle was empty. Tino replaced
the previous old bottle with 50 bar gas left.
37
Sat Mar 28 15:07:40 2020
ruijiu
DAQ
start run
38
Sat Mar 28 15:19:23 2020
ruijiu
start run e121_run_0236.lmd
store 206Pb81+ beam inside ESR and measure
its halflife.
The HV of detector is off.
44
Sun Mar 29 09:40:35 2020
ruijiu
DAQ
restart go4
go4 crush up.
the problem is
due to mbs.
45
Sun Mar 29 09:57:26 2020
ruijiu
Detectors
the HV of charged particle detector
MHV1 MHV2
ch1:1st Sipad 4th
Sipad
46
Sun Mar 29 10:09:14 2020
ruijiu
start run e121_run_0237.lmd
Sergey and Yuri are tuning Tl beam. The particle
number in ers is about 1e4. I(SIS)=5e8
run stop: after few minutes (garbage data)
51
Sun Mar 29 13:05:36 2020
ruijiu
DAQ
start ntcap
IQ_2020-03-29_13-05-
56
SC_2020-03-29_13-05-
53
Sun Mar 29 14:01:45 2020
ruijiu
beam position on DSSD
move the detector 1cm
outside.from 60mm to
70mm.
54
Sun Mar 29 14:29:13 2020
ruijiu
e121_run_00240.lmd
s6 positon at 50mm.
55
Sun Mar 29 18:41:31 2020
ruijiu
Analysis
Ratio between MPWC rate and DSSD rate
slit Ratio error
-1 18.64 0.4
-2 18.18 0.38
58
Sun Mar 29 21:02:43 2020
ruijiu
Analysis
decay line of 205Tl beam
decay line of 205Tl beam with Ar gas jet target
on and S6 slit at -8mm
Ar gas density~1e12 atoms/cm2
60
Sun Mar 29 21:39:27 2020
ruijiu
Analysis
Ionization cross section and capture cross section for h-206Pb + Ar
Ionization cross section = 1320 barn.
Capture cross section = 557+137+44.5=735.5.
sigma_Ion/sigma_cap=1.79
90
Mon Mar 30 12:12:25 2020
ruijiu
General
Instruction of NTCAP for shift person
To start a new run with NTCap, we need to
retart NTCAP.
1. Stop labview program.
95
Mon Mar 30 13:40:57 2020
ruijiu
Detectors
HV of Inner detector
96
Mon Mar 30 13:41:20 2020
ruijiu
Detectors
HV of Inner detector
Goto page 1,