26
Sat Mar 28 01:14:19 2020
Ragan
General
Cross-section for capture and ionisation of 206Pb81+ with H2 target
Cross-section for capture and ionisation of
206Pb81+ with H2 gas jet target are calculated
using GLOBAL code.
27
Sat Mar 28 04:32:15 2020
Ragan
Detectors
Ionisation events on DSSSD
XY co-relation of DSSSD showing 206Pb82+ beam
hitting the CsISiPHOS detector present in
the inner pocket of ESR after the first dipole
28
Sat Mar 28 04:50:34 2020
Ragan
Detectors
MWPC
Alex and Pierre-Michel applied 1500 V to the
anode and adjusted the threshold in Messhute.
x1 signal was small & noisy and rest of the
35
Sat Mar 28 13:19:56 2020
Ragan
Runs
Template
beam:
energy:
storage time:
48
Sun Mar 29 11:12:00 2020
Ragan
Runs
start run e121_run_0239.lmd
Sergey and Yuri are tuning Tl beam. The particle
number in ers is about 1e4. I(SIS)=5e8
57
Sun Mar 29 20:32:20 2020
Ragan
General
Template for Pb halflive measurement
beam:
energy:
59
Sun Mar 29 21:34:46 2020
Ragan
Runs
First run
beam: 206Pb81+
energy: 400 MeV/u
61
Sun Mar 29 21:55:47 2020
Ragan
General
MWPC
Alex goes to Messhute to check the signals
from MPWC. After he completes, we start with
the measurements with the primary beam )
63
Mon Mar 30 00:32:32 2020
Ragan
Runs
First measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u
64
Mon Mar 30 01:01:53 2020
Ragan
Runs
First measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u
65
Mon Mar 30 01:07:29 2020
Ragan
General
Problem with SIS runstop: 0256
There is problem with SIS
Run stop: 0257.lmd (at1:06)
66
Mon Mar 30 01:25:57 2020
Ragan
Runs
First measurement with 206Pb81+ beam
01:17 Problem with SIS is solved
01:19 run start 0258.lmd
67
Mon Mar 30 01:43:58 2020
Ragan
General
First measurement with 206Pb81+ beam pattern details
The following shows the pattern for first
measurement in ESR (gas jet is on for = 60*5
secs = 300 secs as it can be seen on step
68
Mon Mar 30 02:00:46 2020
Ragan
Runs
First measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u
69
Mon Mar 30 02:27:44 2020
Ragan
Runs
Second measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA
beam: 206Pb81+
74
Mon Mar 30 04:15:29 2020
Ragan
General
Second measurement with 206Pb81+ beam at I_cooler = 200 mA
In the picture below, a very nice storage
of 206Pb81+ at 200 mA electron cooler current
for no gas jet target can be seen in ESR.
76
Mon Mar 30 06:15:13 2020
Ragan
Runs
Second measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA
beam: 206Pb81+
78
Mon Mar 30 06:30:52 2020
Ragan
Runs
Second measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA
beam: 206Pb81+
79
Mon Mar 30 06:34:47 2020
Ragan
General
Second measurement with 206Pb81+ beam at I_cooler = 20 mA
In the ESR picture below, the decay of beam
is very fast initially for few minutes and
then the decay is constant. But why does
103
Mon Mar 30 20:51:06 2020
Ragan
Detectors
Bias Voltage for Si-pads
The limit of the leakage current for all Si
pads was increased from 1500 nA to 5000nA