  567   Sun May 30 14:40:55 2021 Jan, SophiaDetectorsreal detector assignment2021************************************
GEM1800 @ 90deg (xray1) 
GLP2000 @ 35deg (xray2)
  
  568   Sun May 30 14:48:09 2021 Jan, SophiaCalibrationrun0215 - crap2021    
  569   Mon May 31 10:08:42 2021 Jan, SophiaRunsE127b runsheet2021   e127b_runsheet.ods 
  570   Mon May 31 14:38:33 2021 SophiaCalibrationRunlist for X-ray detector calibrations after the experiment2021The by Jacobus Swartz created table in entry
335 extended by the calibration after the
experiment.
 Kopie_von_E127_Runlist-calibrations-4-3-1.xlsx 
  571   Wed Jun 2 09:14:04 2021 JanGeneralTelegram Chat Export2021Attached is the exported Telegram chat.
There is the simple PDF and the zip-file
containing the chat in json-format as well
 E127_TelegramChat.pdfE127_TelegramChat_json.zip 
  572   Tue Jun 8 15:06:17 2021 ShahabAnalysisBeam lifetime2021measured beam lifetime after the second deceleration
using parallel plate Schottky detector and
the RSA5103 spectrum analyser. Analysis code
 pgamma_lifetime.001.pngpgamma_lifetime.002.png 
  573   Wed Jun 23 12:29:35 2021 Jan, SophiaCalibrationEfficiency of the x-ray Detectors 2021For the x-ray detectors, efficiencies have
been measured, before and after the experiment
was performed. 
 Effizienz_x_ray_GEM1800_90.pngEffizienz_x_ray_GEM3000_145.pngEffizienz_x_ray_GLP_35_ohne33keV.png 
  574   Thu Jun 24 09:43:01 2021 Jan GloriusDAQUnpacker2021The unpacker used for the production runs
of E127b is located at 
/u/litv-exp/unpacker/unpackexps/e127_TO_2021_with_ECL
  
  575   Thu Jul 8 13:39:34 2021 JanCalibrationElectron cooler parameters2021Below are the results from the e-cooler voltage
offset measurments done by Regina Hess et
al. using the voltage divider (VD).
  
  576   Thu Jul 8 14:07:19 2021 JanCalibrationbeam energies2021Table of ion energies calculated from cooler
parameters
 CodeCogsEqn.pngCodeCogsEqn(1).png 
  577   Wed Jul 14 14:46:05 2021 Jan, SophiaDetectorscollimator geometry2021We have measured the collimator geometry.
The annotations of the variables can be found
in the attached sketch  
 10x 
  578   Wed Oct 13 15:09:04 2021 JanCollaborationK-REC cross sections A. Surzhykov2021Attached are the theory K-REC cross sections
as calculated by Andrey Surzhykov (August
2021).
 DCS_Z_52_Tp_7.049MeV_NEW.datDCS_Z_54_Tp_7.049MeV_NEW.datDCS_Z_52_Tp_6.042MeV_NEW.dat 
  579   Wed Oct 13 15:15:53 2021 JanDAQroot-file header for analysis2021Attached is the header file needed for root
analysis.
 e127b.h 
  228   Mon Mar 23 08:04:07 2020 Shahab, Laszlo,YuryRunsrun entry - run0942020open file : run094

beam: 124Xe54+
 2020-03-23_08-13-00-443.png 
  283   Fri Jun 5 14:06:15 2020 LaszloDetectorsDSSSD and SCRAPER position estimate for Xe and Te experiments2020We don't know the exact absolute positions
of the detector (+scraper) and the beam.
However, what we have to know is only these
 SP54120060514100.pdfDSSSD_new1.pdfIMG_20200321_025644.jpg 
  1   Thu Sep 13 11:42:33 2018 Jan GloriusCollaborationProposal Attached is the beam time proposal submitted
and accepted by the G-PAC in 2017.    
 E127_Reifarth_pg.pdfE127_Approval.pdf 
  2   Thu Jan 17 08:45:43 2019 JanDetectorsMicron W1 DSSSD - technical information Attached are the spec sheets and design drawings
of the new DSSSDs from Micron.
Additionally, the 3D model made by Laszlo
 6x 
  3   Wed Feb 6 10:04:23 2019 Laszlo VargaSimulationsBackground subtraction for 124Xe, 109In, 73As made by MOCADI General remarks to the MOCADI simulations:


scraper size vertically > (p,g) spot at the
scraping position --> (p,g) can be separated
 template.pdf 
  4   Wed Feb 6 10:16:09 2019 Laszlo VargaGeneralStudy on scraping A publication on scraping systems suggested
by Siegbert. 
In the study they have used cylindrical "high-quality"
 1-s2.0-0168583X88900122-main.pdf 
  5   Fri Apr 5 05:46:20 2019 JanDAQrunning DRASI for (p,g) We now have a drasi DAQ running for our (p,g)
experiments.
The RIO we have it installed right now is:
  
ELOG V3.1.5-fc6679b