Tue Apr 21 22:25:00 2020 | 
Jan | Analysis |   |   |   | 
   | 
| 
  274  
 | 
Wed Apr  8 23:02:24 2020 | 
Laszlo | General | lmd to measurement pairing list |   | I use the following list of lmd files combined 
to a single root file for each measurement.
 
It is very important to highlight that sometimes | 
    | 
| 
  273  
 | 
Wed Apr  8 20:06:10 2020 | 
Laszlo | Calibration | Counts in the K-REC peaks |   | 3 datasets were investigated:
 
-124Xe with Scraper    (2. Xray calibration 
parameters needed)
 | 
      | 
| 
  272  
 | 
Mon Apr  6 23:00:51 2020 | 
Laszlo | Calibration | beam energies for 124Xe and 118Te measurements |   | "The e- cooler settings were the same for 
the 124Xe and 118Te beams" - Sergey --> speed 
of the ions is the same --> same MeV/u
 | 
    | 
| 
  271  
 | 
Mon Apr  6 04:39:19 2020 | 
Laszlo | Calibration | 2. Xray energy calibration |   | 30angle:  E[keV] = 0.015898 *ch-1.91
 
90angle:  E[keV] = 0.0211075*ch-2.39
 
145angle: E[keV] = 0.01663  *ch-1.758 | 
 9x   | 
| 
  270  
 | 
Sun Apr  5 20:34:42 2020 | 
Laszlo | Calibration | Xray energies - 1. calibration |   | 30angle:  E[keV] = 0.0158507 *ch-2.07456
 
90angle:  E[keV] = 0.01950*ch-2.76
 
145angle: E[keV] = 0.017988  *ch-1.809
 | 
 8x   | 
| 
  269  
 | 
Thu Mar 26 12:05:22 2020 | 
Laszlo | Calibration | measurement of collimators |   | The measurements were taken by using a caliper 
ruler, with precision of +/-0.05mm | 
     | 
| 
  268  
 | 
Wed Mar 25 15:06:09 2020 | 
Laszlo | Analysis | quick summary of the run numbers |   |   | 
    | 
| 
  267  
 | 
Wed Mar 25 14:26:22 2020 | 
Laszlo | Calibration | run111 - Xray90 calib Am241, distance 167.5mm - LESS NOISE |   | Detector: 90
 
Source: 241Am
 
Distance: 167.5mm
 | 
   | 
| 
  266  
 | 
Tue Mar 24 10:59:18 2020 | 
Jan | Calibration | Sources - Specifications |   | We used the following sources:
 
 
[B]Am241[/B] (OM666) [GSI - Uwe]
 | 
       | 
| 
  265  
 | 
Tue Mar 24 10:20:26 2020 | 
Laszlo | Calibration | Pictures of the xray calibration |   |   | 
       | 
| 
  264  
 | 
Tue Mar 24 00:11:35 2020 | 
Laszlo | Calibration | run116 - Xray35 calib AM241, distance 334mm |   | Detector: 35
 
Source: 241Am
 
Distance: 334mm
 | 
   | 
| 
  263  
 | 
Mon Mar 23 22:25:41 2020 | 
Laszlo | Calibration | run115 - Xray35 Ba133 d=334mm, Xray90 Lead source, d=167.5mm |   | Simultaneous measurement of Xray35 and Xray90. 
The dead-time is <3%
 
 | 
   | 
| 
  262  
 | 
Mon Mar 23 21:47:40 2020 | 
Laszlo | Calibration | run114 - Xray145 calib Ba133, distance 305mm - LESS NOISE |   | Detector: 145
 
Source: 133Ba - strong source
 
Distance: 305mm
 | 
   | 
| 
  261  
 | 
Mon Mar 23 20:52:37 2020 | 
Laszlo | Calibration | run113 - Xray145 calib Am241, distance 305mm - LESS NOISE |   | Detector: 145
 
Source: 241Am
 
Distance: 305mm
 | 
   | 
| 
  260  
 | 
Mon Mar 23 19:32:53 2020 | 
Laszlo | Calibration | run112 - Xray90 calib Am241, distance 200mm - LESS NOISE |   | Detector: 90
 
Source: 241Am
 
Distance: 200mm
 | 
   | 
| 
  259  
 | 
Mon Mar 23 18:17:27 2020 | 
Laszlo | Calibration | run110 - Xray90 calib Ba133, distance 167.5mm -low rate - LESS NOISE |   | Detector: 90
 
Source: Ba133 - weak source
 
Distance: 167.5mm
 | 
   | 
| 
  258  
 | 
Mon Mar 23 18:15:55 2020 | 
Laszlo | General | noisy 90degree Xray det |   | Uwe found out, that there was some common 
ground effect between 90 and 145 degree detectors. 
after moving the grounds, we could record | 
   | 
| 
  257  
 | 
Mon Mar 23 17:40:33 2020 | 
Laszlo | Calibration | run109 - Xray90 calib Ba133, distance 167.5mm -low rate |   | Detector: 90
 
Source: Ba133 - weak source
 
Distance: 167.5mm
 | 
   | 
| 
  256  
 | 
Mon Mar 23 17:32:42 2020 | 
Laszlo | Calibration | run108 - Xray90 calib Ba133, distance 167.5mm - high rate - deadtime too high! |   | Detector: 90
 
Source: Ba133 - strong source
 
Distance: 167.5mm
 | 
   |