284
Fri Oct 23 12:58:12 2020
Jan
Detectors
Test of 2nd DSSSD (gen2)
2021
This is the documentation of the source tests
with the 2nd micron DSSSD of 2nd generation
(label 3288-17, thickness 529um)
285
Fri Nov 20 15:53:37 2020
Jan
Analysis
Test of 2nd DSSSD (gen2)
2021
Here is the analysis of the test runs with
the 2nd DSSD (gen2) using the quick_si_plots.c
script attached.
286
Tue Nov 24 15:35:49 2020
Jan
Calibration
DSSD X/Y channel mapping
2021
During the detector test [URL=https://elog.gsi.de/esr/E127/284]test
measurements[/URL] with alpha source the
allocation of the 16 X- and 16 Y-channels
287
Tue Feb 2 13:59:00 2021
Jan
Detectors
DSSD installation and alignment
2021
The DSSD has been exchanged and aligned in
November 2020. After bakeout at 140°C
288
Wed Mar 31 13:52:04 2021
Jan
Detectors
BaF Na22 Testing
2021
On 30. and 31.03.2021 we did some testing
with the 6 BaF detectors.
289
Wed Mar 31 13:57:27 2021
Jan
Detectors
BaF HV settings
2021
The setting below is a start value for final
gain matching with a full ADC range of 12MeV:
290
Wed Apr 14 09:42:50 2021
Jan
Detectors
BaF HV gain matching
2021
The preliminary gain matching settings for
a full ADC range of ~12MeV:
291
Thu Apr 22 10:56:20 2021
Jan
Detectors
target-chamber det. distances
2021
This is the lookup table for the distance
of each x-ray detector to the target.
See attached foto for explanation.
292
Wed Apr 28 09:12:47 2021
Jan, Yuri
Detectors
UI-diagram
2021
The UI-curve of the detector
U I
10 0.11
293
Thu Apr 29 20:32:52 2021
Jan Glorius
Calibration
calibration sources
2021
We use the following list of sources for calibration
of the Xray detectors:
294
Thu Apr 29 20:34:09 2021
Jan Glorius
Calibration
run0003 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
295
Fri Apr 30 09:27:27 2021
Jan Glorius
Calibration
run0004 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
296
Fri Apr 30 09:57:57 2021
Jan Glorius
Calibration
run0005 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
297
Fri Apr 30 10:55:34 2021
Jan Glorius
DAQ
Xray multi-triggers - blocking gate
2021
From the CFD of Xray1 (90deg) we get multiple
trigger signals every ~5sec for unknown reasons.
298
Fri Apr 30 11:04:31 2021
Jan Glorius
Calibration
run0006 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
299
Fri Apr 30 13:07:23 2021
Jan Glorius
Calibration
run0008 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
300
Fri Apr 30 13:10:44 2021
Jan Glorius
Calibration
run0007 - crap
2021
crap run
301
Fri Apr 30 13:56:59 2021
Jan Glorius
Calibration
run0009 - Xray90 calib Am241 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
302
Fri Apr 30 14:35:11 2021
Jan Glorius
Calibration
run0010 - Xray90 calib Ba133 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
303
Fri Apr 30 14:48:01 2021
Jan Glorius
Calibration
run0011 - Xray90 calib Ba133_low d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg