572 Entries
Goto page
Previous
1
,
2
,
3
...
23
, 24,
25
...
27
,
28
,
29
Next
ID
Date
Author
Category
Subject
Year
Text
262
Mon Mar 23 21:47:40 2020
Laszlo
Calibration
run114 - Xray145 calib Ba133, distance 305mm - LESS NOISE
Detector: 145
Source: 133Ba - strong source
Distance: 305mm
263
Mon Mar 23 22:25:41 2020
Laszlo
Calibration
run115 - Xray35 Ba133 d=334mm, Xray90 Lead source, d=167.5mm
Simultaneous measurement of Xray35 and Xray90.
The dead-time is <3%
264
Tue Mar 24 00:11:35 2020
Laszlo
Calibration
run116 - Xray35 calib AM241, distance 334mm
Detector: 35
Source: 241Am
Distance: 334mm
265
Tue Mar 24 10:20:26 2020
Laszlo
Calibration
Pictures of the xray calibration
266
Tue Mar 24 10:59:18 2020
Jan
Calibration
Sources - Specifications
We used the following sources:
[B]Am241[/B] (OM666) [GSI - Uwe]
267
Wed Mar 25 14:26:22 2020
Laszlo
Calibration
run111 - Xray90 calib Am241, distance 167.5mm - LESS NOISE
Detector: 90
Source: 241Am
Distance: 167.5mm
269
Thu Mar 26 12:05:22 2020
Laszlo
Calibration
measurement of collimators
The measurements were taken by using a caliper
ruler, with precision of +/-0.05mm
270
Sun Apr 5 20:34:42 2020
Laszlo
Calibration
Xray energies - 1. calibration
30angle: E[keV] = 0.0158507 *ch-2.07456
90angle: E[keV] = 0.01950*ch-2.76
145angle: E[keV] = 0.017988 *ch-1.809
8x
271
Mon Apr 6 04:39:19 2020
Laszlo
Calibration
2. Xray energy calibration
30angle: E[keV] = 0.015898 *ch-1.91
90angle: E[keV] = 0.0211075*ch-2.39
145angle: E[keV] = 0.01663 *ch-1.758
9x
272
Mon Apr 6 23:00:51 2020
Laszlo
Calibration
beam energies for 124Xe and 118Te measurements
"The e- cooler settings were the same for
the 124Xe and 118Te beams" - Sergey --> speed
of the ions is the same --> same MeV/u
273
Wed Apr 8 20:06:10 2020
Laszlo
Calibration
Counts in the K-REC peaks
3 datasets were investigated:
-124Xe with Scraper (2. Xray calibration
parameters needed)
277
Thu Apr 23 19:09:58 2020
Laszlo
Calibration
theoretical K-REC cross sections
Find attached Andrey Surzhykov's calculations
for the theta angle in respect to the beam
direction (in lab. frame) vs. cross section
9x
278
Wed Apr 29 16:06:28 2020
Laszlo
Calibration
efficiency fit - 90degree, combined dataset
For the efficiency vs E fit of the 90degree
Xray detector I have used the following phenomenological
funciton:
279
Thu Apr 30 17:40:57 2020
Laszlo
Calibration
efficiency fits
For all 3 detector the calibration data sets
were combined to include the systematics
in the fit results directly. Combining means
280
Thu Apr 30 22:55:45 2020
Laszlo
Calibration
inverse square law test
I have made also the inverse square law fits.
We have data only for 90degre with the 241Am
source, but both for the 1. and 2. calibrations.
281
Wed May 6 23:02:42 2020
Laszlo
Calibration
efficiency values
I have calculated the efficiency values by
putting the energies of the K-REC peaks into
the phenomenological (empirical) function
286
Tue Nov 24 15:35:49 2020
Jan
Calibration
DSSD X/Y channel mapping
2021
During the detector test [URL=https://elog.gsi.de/esr/E127/284]test
measurements[/URL] with alpha source the
allocation of the 16 X- and 16 Y-channels
293
Thu Apr 29 20:32:52 2021
Jan Glorius
Calibration
calibration sources
2021
We use the following list of sources for calibration
of the Xray detectors:
294
Thu Apr 29 20:34:09 2021
Jan Glorius
Calibration
run0003 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg
295
Fri Apr 30 09:27:27 2021
Jan Glorius
Calibration
run0004 - Xray90 calib Pb210 d=167.5mm
2021
Efficiency calibration in the lab
Detector: GEM1800 - 90 deg