HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  Nuclear hyperfine mixing in 229Th89+, Page 10 of 12  Not logged in ELOG logo
IDdown Date Author Category Subject Text Attachments
  54   Fri Apr 1 15:52:23 2022 RodolfoDetectorsUV PMT SouthThe "Solar Blind PMT" labeled as "PMT South"
has been installed by Simon and Max in the
gas target chamber on a CaF Viewport. The
 PMT_Sued_Target.jpg 
  53   Fri Apr 1 15:27:00 2022 RodolfoDetectorsNitrogen for UV-PMTsThere was a question concerning the nitrogen
we use to rinse the "Solar Blind PMTs".
 Stickstoff_f_PMTs.jpgStickstoff_Flussrate.jpg 
  52   Fri Apr 1 11:19:57 2022 Rui-Jiu ChenDAQS.M.A.R.T check on NTCAPS.M.A.R.T. check has been done on NTCAP on
March 28th. All 12 hard disk drivers  are
normal.
 image001(04-01-11-10-06).jpg 
  51   Fri Apr 1 11:00:41 2022 Rui-Jiu ChenDAQStart NTCAPStart taking data with NTCAP.
Carrier Frequency: 245MHz
IQ rate:5 MSamples/s
  
  50   Fri Apr 1 02:29:40 2022 Carsten ESR Cooler crashedESR cooler crashed. We could not restart the
cooler. Since we had several other problems,
we stop now.
  
  49   Fri Apr 1 01:57:12 2022 KristianDAQTimingwith bunched primary beam (bunching frequency
1.94070 MHz) we have strong PMT (mid) and
particle detector signal. Time between both
 Particle-PMT_Mid.pngPMT-PD.pngIMG_20220331_235846.jpg 
  47   Fri Apr 1 00:27:27 2022 Carsten Settings Particle Detectors /Tests with primary beamAll the beam settings will be given in a separate
post.
  
  46   Thu Mar 31 22:41:35 2022 KristianCalibrationHV dividerWe noticed a difference in the electron cooler
high voltage:
 HV-divider2.png 
  45   Thu Mar 31 22:19:14 2022 KristianDAQHow To Start MBS(MBS server should be running at the LXG1297
machine. If not you will get an error message.
Then start the server - last command in console)
  
  44   Thu Mar 31 20:07:47 2022 ShahabDAQSchottky Display in AP Messhütte (or anywhere else)[B]UPDATE: 16.05.2022[/B]

[I]Please use ATPPC029 instead of ATPPC019
 04_PM_schottky.png 
  43   Thu Mar 31 17:56:32 2022 KonstantinDAQPhotodiode test signalWe used a signal generator to provide a 4MHz
dummy-RF signal. This was divided by a factor
of 2 for laser-"bunch" synchronization and
 Timing_Photodiodes.png 
  42   Thu Mar 31 15:53:50 2022 KonstantinDetectorsControl software for XUV and copper mirror detector> Attached you find a manual for the software
used to control the movement of the XUV detector
and the copper mirror detector. 
 XUV_Cu_GUI.png 
  41   Thu Mar 31 13:28:17 2022 Jan GloriusDAQDAQ-2 cabling docunewest version V2 - valid since Mo 04.April
2022
 e142_daq2_cabling.pdfe142_daq2_cabling_V2.pdfe142_daq2_cabling_V2.ods 
  40   Thu Mar 31 11:49:54 2022 KonstantinDetectorsHV-Supply of particle detectors We cross-checked the cabeling of the particle
detectors north and south. Particle detector
south is connected to channel [B]HV5[/B]
  
  39   Wed Mar 30 09:27:15 2022 RodolfoAcceleratorIssue? Scrapers at E-CoolerCarsten* forwarded me an E-Mail from Markus
yesterday. "Betreff: Scraper im ESR Elektronenkühler"
 Schrittmotorsteuerung_ECooler.JPG 
  38   Tue Mar 29 21:37:13 2022 RodolfoLaserPump LaserThe gold "reflectors and end plates" of our
pump laser (Quanta-Ray PRO) have been exchanged
by new ones.
 QRay_GoldReflektoren_2010-2022.jpg 
  37   Tue Mar 29 12:47:26 2022 Ken Ueberholz Parameter setting for XUV and copper mirror detector Some Default Settings for the XUV 
Detector. The copper 
mirror should always move fully in.
  
  36   Tue Mar 29 12:01:08 2022 RodolfoLaserLaser targetsI have installed two targets* (size: 2 inches)
to monitor the position of the laser beam.
 TargetIN_SO.pngTargetOUT_NO.pngTargetControlBox.jpg 
  35   Fri Mar 25 14:31:24 2022 RodolfoLaserPhotodiode signal SO in the MesshütteMeasured at the Panel "Messhütte - Laserhütte",
BNC "Fast PD / SO".
 PD_SO_Signal_MH_25-03-2022.PNG 
  34   Thu Mar 24 17:10:33 2022 CarstenDAQDAQ / MBS VUPROM TDC buffer errorsVUPROM TDC buffer errors potentially due to
long TDC common Stop gate (>1ms from div
200).
  
ELOG V3.1.5-fc6679b