  218   Tue Apr 12 14:11:52 2022 RaganDetectorsSideband in Schottky
> Sometimes we see a broad sideband at lesser Schottky frequencies to the high-intensity thorium beam.
> 
> Pic 1 shows the relative broad sideband on the left.
> 
> Pic 2 depicts the vanishing of the sideband after ~1-2 minutes.


These are not the sidebands. Maybe some short-lived fragments survive even after the scrapers are used?
  217   Tue Apr 12 13:24:40 2022 Alexandre, SebastianDetectorsSideband in Schottky
Sometimes we see a broad sideband at lesser schottky frequencies to the high intensity thorium beam.

Pic 1 shows the relative broad sideband on the left.

Pic 2 depicts the vanishing of the sideband after ~1-2 minutes.
Attachment 1: IMG_20220412_125530_resized_20220412_125736155.jpg
IMG_20220412_125530_resized_20220412_125736155.jpg
Attachment 2: IMG_20220412_125643_resized_20220412_125736537.jpg
IMG_20220412_125643_resized_20220412_125736537.jpg
  216   Tue Apr 12 12:41:20 2022 Alexandre, SebastianAcceleratorno beam in SIS18
  215   Tue Apr 12 04:43:29 2022 Alexandre, Kristian, SebastianRuns322.01 - 321.60 nm
We scan the wavelength scan range is 322.01 - 321.60 nm

before the first scan of the new wavelength range we changed the high voltage divider ratio in Labview from 248514 to 248517, which is the correct value for this voltage. This leads to slightly higher cooler voltages in the log.

TimeSIS-intensitycooler-HVLMD-DAQ2 file nr LMD-DAQ1 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
04:40 1.9e9 209625 0203 7938 322.01 - 321.60 0.002 5s 8830
05:20 1.7e9 209626 0204 7939 322.01 - 321.60 0.002 5s 7800
06:00 1.6e9 209626 0205 7940 322.01 - 321.60 0.002 5s 8500
06:45 1.7e9 209620 0206 7941 322.01 - 321.60 0.002 5s 9400 cooler HV decreased slowly by a few V, jumped back at ~7:03
07:25 1.8e9 209620 0207 7942 322.01 - 321.60 0.002 5s 9300
08:05 1.75e9 209620 0208 7943 322.01 - 321.60 0.002 5s 9100
08:45 1.7e9 209618 0209 7944 322.01 - 321.60 0.002 5s 9000 cooler HV decreased 5V to 209614 and jumped back to initial value after ~5s
09:25 1.7e9 209618 0210 7945 322.01 - 321.60 0.002 5s 8500
10:05 1.9e9 209618 0211 7946 322.01 - 321.60 0.002 5s 9200 cooler HV decreased steadily to 209611 V during the run
10:45 1.9e9 209611 0212 7947 322.01 - 321.60 0.002 5s 7500 After injecting into the ESR, we saw after cooling some tails left and right of the Shottky peak of Th. Was not there in the runs before. After some minutes it disappeared in the spectrum
11:35 2e9 209611 0213 7948 322.01 - 321.60 0.002 5s it seems to be that much lesser ions are stored in the ESR - counter shows low rate - ABORTED laser didn't start scanning
11:58 1.75e9 209615 0214 7949 322.01 - 321.60 0.002 5s 7700 cooler HV jumped to 209610 at 12:12 and stayed there
12:53 1.85e9 209611 0215 7950 322.01 - 321.60 0.002 5s 7155 cooler HV increased slowly from initial value to ~209618
13:32 1.9e9 209612 0216 7951 322.01 - 321.60 0.002 5s 6638
14:39 1.8e9 209610 0217 7952 322.01 - 321.60 0.002 5s 6815 Voltage was jumping around from 209610 up to 209624 and back
15:20 1.75e9 209612 0218 7953 322.01 - 321.60 0.002 5s 8400 In contrast to the previous measurement, the cooler voltage was drifting by about 3V around 209612
16:00 1.7e9 209612 0219 7954 322.01 - 321.60 0.002 5s 7920
16:58 1.5e9 209612 0220 7955 322.01 - 321.60 0.002 5s 4577 PMT North voltage and threshold modified Entry 221, Ecooler voltage dcreased to 209609 V, weak injection
18:09 1.62e9 209609 0221 7957 322.01 - 321.60 0.002 5s During the last injection the beam suddenly got lost during the scraping, File 7956 was discarded since go4 was still during the startup of mbs
18:49 1.69e9 209609 0222 7958 322.01 - 321.60 0.002 5s 6133
19:49 1.6e9 209610 0223 7959 322.01 - 321.60 0.002 5s 7035
20:29 1.78e9 209611 0224 7960 322.01 - 321.60 0.002 5s 4490
21:12 1.86e9 209622 0225 7961 322.01 - 321.60 0.002 5s 10296 Note that the cooler voltage is increased. Particle number might be overestimated since it was read when the beam was already dumped.
Attachment 1: DriftingVoltage14-40.PNG
DriftingVoltage14-40.PNG
  214   Mon Apr 11 22:33:16 2022 CarstenGeneralBackup of data to the external RAID disks
  213   Mon Apr 11 22:14:51 2022 Konstantin, SarperLaserChanging of the wavelength range
It is planned to change the scan range of the laser wavelength from 322.41 - 322.0 nm to 322.01 - 321.6 nm @ 4 a.m. 
  212   Mon Apr 11 18:57:18 2022 RodolfoLaserNew flashlamps
We (Sarper, Konstantin and me) have changed the old flashlamps (with ~ 26 Mio. shots) by new "fresh" ones. We have also exchange the dye. Here are some parameters of the laser we measured with the new flashlamps and dye*:

- Output energy after the Quanta-Ray (@ 532 nm): 598 mJ.
- Seed energy for Cobra (@ 532 nm): 505 mJ.
- Correction factor for monitor; 15.9.
- Output energy after Cobra's main amplifier cell (@ 640 nm): 107 mJ.
- Output energy after SHG (@ 320 nm): 15.8 mJ.


* all values are average over 500 shots.
** below you can see a picture of the "old" flashlamps.
Attachment 1: Blitzlampe_26Mio_Schüsse_11-04-2022.jpg
Blitzlampe_26Mio_Schüsse_11-04-2022.jpg
  211   Mon Apr 11 18:46:31 2022 Rodolfo, Sarper and KonstantinLaserAlignment-check
We cross-checked the laser-ion alignment. The horizontal position was optimized. However, 
since the laser beam is much larger than the ion beam, this was not an issue for measurements, which
have been performed during the last shifts.
The modified parameters of the stabilization system are attached.
Attachment 1: MRC_Konfiguration_MitMainAmp_04-11-2022.png
MRC_Konfiguration_MitMainAmp_04-11-2022.png
  210   Mon Apr 11 14:45:11 2022 Paul, Konstantin, Sarper, DavidRunsAfternoon shift runs 11.04
We continue scan the new wavelength scan range is 322.41 - 322.00 nm



TimeSIS-intensitycooler-HVLMD-DAQ1 file nr LMD-DAQ2 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
14:45 1.9e9 209618 0189 7924 322.41 - 322.00 0.002 5s 9100
18:54 1.83e9 209616 0191 7926 322.41 - 322.00 0.002 5s 7300
19:34 1.7e9 209615 0192 7927 322.41 - 322.00 0.002 5s 7110
20:13 1.8e9 20961X 0193 7928 322.41 - 322.00 0.002 5s 6730
20:53 1.8e9 209614 0194 7929 322.41 - 322.00 0.002 5s 7550 During the scan the ecooler voltage changed to approximately 209613
21:43 1.7e9 209614 0195 7931 322.41 - 322.00 0.002 5s 7000
22:30 1.6e9 209612 0197 7932 322.41 - 322.00 0.002 5s 7300
23:10 1.4e9 209614 0198 7933 322.41 - 322.00 0.002 5s 6100 For this measurement, ESR_Ring went red, we realized only after completing the measurement. The sections went red are Dipole Correction Points (GE01KP17-18-19-20, 4 in total) @~23:45 and fixed @01:35...
01:52 1.6e9 209614 0199 7934 322.41 - 322.00 0.002 5s 7151
02:32 1.7e9 209616 0200 7935 322.41 - 322.00 0.002 5s 8368
03:22 1.8e9 209617 0201 7936 322.41 - 322.00 0.002 5s 7005
04:01 1.9e9 209616 0202 7937 322.41 - 322.00 0.002 5s Ecooler voltage increased 4 volts during the run
  209   Mon Apr 11 12:50:22 2022 KristianAcceleratorTh lifetime
We used the counter to measure the lifetime. During the 30 min scan time dropped only slowly. 

During a longer break, e.g., when the laser flash lamps are changed, one could take data over a longer time.
Attachment 1: ThLifetime.JPG
ThLifetime.JPG
  208   Mon Apr 11 11:05:35 2022 Sebastian, KristianLaserCheck laser power
we checked the UV laser power at 10:15 am. It was only 8.5 - 9 mJ. Pumping power was 460 mJ, which is the maximum output of the current system. We should change the flashlamps soon
  207   Mon Apr 11 10:31:07 2022 Kristian, Sebastian, Alexandre, Danyal, PaulGeneralnew laser wavelength scan range 322.41 - 322.00 nm
new wavelength scan range is 322.41 - 322.00 nm

at 10:31

TimeSIS-intensitycooler-HVLMD-DAQ1 file nr LMD-DAQ2 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
10:31 1.75e9 209617 0180 7915 322.41 - 322.00 0.002 5s 2300 ABORT ... no laser ... beam stabilization was off
10:40 xxe9 209617 0181 7916 322.41 - 322.00 0.002 5s xxx ABORT ... laser did not start from 322.41 nm
10:42 xxe9 209615 0182 7917 322.41 - 322.00 0.002 5s xxx ABORT ... laser did not start from 322.41 nm
10:45 2.1e9 209616 0183 7918 322.41 - 322.00 0.002 5s 9236 HV E-cooler fluctuates slowly over 3 V
11:22 1.7e9 209616 0184 7919 322.41 - 322.00 0.002 5s xxx
12:02 2.0e9 209616 0185 7920 322.41 - 322.00 0.002 5s 9660
12:43 1.8e9 209618 0186 7921 322.41 - 322.00 0.002 5s 6533 HV E-cooler jump to ~209700k for ~10 seconds and than back to 209618
13:24 2.0e9 209617 0187 7922 322.41 - 322.00 0.002 5s 9500
14:05 2.0e9 209618 0188 7923 322.41 - 322.00 0.002 5s 9220
  206   Mon Apr 11 10:17:01 2022 DanyalAcceleratorInterlock - reset
10:17 
Wie heutemorgen in der Sitzung (morning briefing) vereinbart, 
führt Herr Florenkowski einen Interlock und danach einen Reset von E02MK durch. 
Das dauert nur ca. 15 min. 

nach dem interlock wurde der ESR "rot" 

Um 10:21 war das problem gelöst und der ESR war wieder "blau"
  205   Mon Apr 11 07:54:37 2022 Danyal, Alexandre, Kristian, SebastianAcceleratorJump in E-cooler voltage
We saw a jump in the E-cooler voltage at about 7:50. 
jump from 209619 to 209610 V 

At 7:56 it jumped back to 209619 V
seems stable now  
  204   Mon Apr 11 04:26:53 2022 PatrickDAQNext wavelength range
Measurements with the next wavelength scan range should be started roughly around 10:00 am.
The next wavelength scan range is planned to be 322.41 - 322.00 nm, again with a step size of 0.002 nm, 5s dwell time and 2 loops.
This range includes roughly a third of the first scan range.
  203   Sun Apr 10 22:47:05 2022 Patrick, Volker, Prannay, Danyal, Alexandre, Sebastian, KristianRunsRuns night shift 10.04 + morning shift 11.04
These are the measurement runs of the night shift (10/11.04.).

Wavelength range is still 322.81 - 322.40 nm.


TimeSIS-intensitycooler-HVLMD-DAQ1 start-endLMD-DAQ2 start-endscan range(nm)step width(nm)dwell time(s)particles countedcomments
23:05 1.75e92096200165 - 01657901-7901322.81 - 322.400.0025s8500
23:57 1.?e92096200166 - 01667902-7902322.81 - 322.400.0025s8500The HV of PMT south was changed from 2.5kV to 3kV
00:35 1.4e92096200167 - 01677903-7903322.81 - 322.400.0025s4100
01:18 1.75e92096200168 - 01687904-7904322.81 - 322.400.0025s4400
01:58 1.4e92096200169 - 01697905-7905322.81 - 322.400.0025s7700 The ESR went red after this run. The on-call service was called because of some power supply failure, ETA: 45min.
04:12 1.75e92096200171 - 01717906-7906322.81 - 322.400.0025s7600 With the start of this run, the wavemeter, labview and the python script were restarted. The python script was slightly adjusted.
04:50 1.6e92096200172 - 01727907-7907322.81 - 322.400.0025s8300
05:31 1.6e92096190173 - 01737908-7908322.81 - 322.400.0025s8100
06:09 1.6e92096150174 - 01747909-7909322.81 - 322.400.0025s 8000
06:52 1.8e92096150175 - 01757910-7910322.81 - 322.400.0025s8800 at 07:08 the cooler voltage jumped from 209615 V to 209619 V
07:30 1.9e92096190176 - 01767911-7911322.81 - 322.400.0025s forgotten at 07:50 the cooler voltage jumped from 209619 to 209610 V and back again at to 209619 V
08:18 1.8e92096190177 - 01777912-7912322.81 - 322.400.0025s 9100 08:47 the cooler voltage jumped from 209618 to 209614 V and back again at to 209618 V
08:55 1.75e92096190178 - 01787913-7913322.81 - 322.400.0025s 8300
09:36 1.6e92096190179 - 01797914-7914322.81 - 322.400.0025s 8194


The SIS intensity is taken directly before injection to ESR. Not the SIS peak intensity as in yesterday's table.
  202   Sun Apr 10 15:29:53 2022 RodolfoLaserStatus - Laser system
We have checked the laser system.

- The pump laser has ~ 23Mio shots. The total output energy has dropped to about 475 mJ. Maybe it is time to install new fresh flashlamps. In case the accelerator is going to have any mantainance tomorrow (Monday) then we can take the oportunity to exchange the flashlaps.
- The dye laser is pumped with 470 mJ (angle of lambda/2 plate = 112°).
- The energy after the second harmonic is 11,3 mJ @ 646 nm. We are using the Sarper's calibration table (635 nm - 646 nm)
  201   Sun Apr 10 15:29:37 2022 Carsten,SarperAcceleratorEcooler failed
Ecooler failed @15:23 Carsten is fixing it
Fixed @16:00
  200   Sun Apr 10 15:16:19 2022 Carsten, Rodolfo, SarperRunsRuns afternoon shifts 10.04
These are the measurement runs of the afternoon shift (10.04.).

Wavelength range is changed from 323.2 - 322.8 nm to 322.81 - 322.40 nm.


TimeSIS-intensitycooler-HVLMD-DAQ1 start-endLMD-DAQ2 start-endscan range(nm)step width(nm)dwell time(s)comments
16:261.95e92096200155-01557891-7891322.81 - 322.400.0025slaser scan did not work, labview (Thorium_main.vi) communication issue
16:511.8e92096200156-01567892-7892322.81 - 322.400.0025s
17:331.6e92096180157-01577893-7893322.81 - 322.400.0025s 7894 particles on the counter
18:171.6e92096180158-01587894-7894322.81 - 322.400.0025s 8200 particles on the counter
19:061.8e92096180159-01597895-7895322.81 - 322.400.0025s 8650 particles on the counter
19:441.9e92096180160-01607896-7896322.81 - 322.400.0025s 8600 particles on the counter
20:241.7e92096200161-01617897-7897322.81 - 322.400.0025s 4200 particles on the counter
21:041.7e92096190162-01627898-7898322.81 - 322.400.0025s 8380 particles on the counter
21:451.8e92096190163-01637899-7899322.81 - 322.400.0025s 8550 particles on the counter
22:241.8e92096190164-01647900-7900322.81 - 322.400.0025s 8016 particles on the counter
  199   Sun Apr 10 15:08:42 2022 CarstenDAQBackup of Data from 1rst Scanrange to extrenal RAID1 HDDs
I just performed a backup of all data (+log-Files) that were collected until now to the two RAID HDDs.

For DAQ1: /media/sdc2 - last file 229Thor7889.lmd. Please note, that the naming sceme on DAQ1 is inconsistent - please look for the filenumnbering
For DAQ2: /media/sdd2 - last file 229Th0153.lmd