| ID | Date | Author | Category | Subject | Text |  | 
| 177 | Sat Apr  9 04:01:35 2022 | Carsten |  | 2nd DAQ | Switched the CAEN TDC back on and changed the threshoolds for the ADC to:
 
 |  | 
| 176 | Sat Apr  9 03:57:10 2022 | Carsten | Accelerator | New Cooler voltage after the crash of the cooler | After the restart of the cooler the Ohmlabs divider showed a voltage 16V lower than before.
 This could also be seen as a slight shift
 |  | 
| 175 | Sat Apr  9 03:46:31 2022 | Carsten | Accelerator | Slits in TE line | Changed GTEDSAH Rechts to 10mm |  | 
| 174 | Sat Apr  9 03:27:47 2022 | Patrick | DAQ | Laser scanning | DAQ1: lxg1927:/data.local2/BeamTimeTh22/ DAQ2: lxg0155:/data.local2/E142/
 LMD file name DAQ1:229Thor
 |   | 
| 173 | Sat Apr  9 02:55:38 2022 | Carsten | Accelerator | Kühlerausfall und Gründe dazu | Wir hatten heute Abend eine Kühlerausfall, der uns mehrere Stunden beschäftigt hat,
 weil  gem. Anzeige in Device Control kein
 |  | 
| 172 | Fri Apr  8 23:56:07 2022 | Patrick | DAQ | DAQ improvement | As requested in ID:146 and ID:147, the laserscan tab was improved:
 [LIST]
 |  | 
| 171 | Fri Apr  8 22:26:44 2022 | Patrick | DAQ | Spike in all detectors | In the previous shift, there was a spike in all detectors in the same scan step. Apparently,
 this was NOT a resonance since in the next
 |  | 
| 170 | Fri Apr  8 17:57:45 2022 | Konstantin | DAQ | Laser scanning | 
 [TABLE border="1"]
 |   | 
| 169 | Fri Apr  8 17:44:25 2022 | Konstantin | Calibration | Final Timing | We measured the timing for the laser bunch synchronization. A summary is given below.
 
 |  | 
| 168 | Fri Apr  8 15:45:24 2022 | YL |  | Spectrum manipulation 5 | See attached |   | 
| 167 | Fri Apr  8 15:42:20 2022 | Yuri | Accelerator | Slits in the TE line | At around 15:00, The slits in the TE line were changed to :
 TE4DS5HL -12 mm -> -20 mm
 |  | 
| 166 | Fri Apr  8 15:39:36 2022 | all | Runs | first data after timing set up | started taking data again 
 started at 15:40
 |  | 
| 165 | Fri Apr  8 14:46:02 2022 | Danyal & Sebastian & Volker & Ken | Detectors | high dark countrate Cu PMT solved | The problem - "discovered" by Volker and Ken - of the high dark countrate of the Cu PMT
 has been solved.
 |    | 
| 164 | Fri Apr  8 14:43:50 2022 | Wilfried | DAQ | laser timing - Q-switch start | below are my notes concerning laser timing / Q-switch start
 |   | 
| 163 | Fri Apr  8 14:14:28 2022 | Kristian | DAQ | Delay of bunch RF | The bunch HF is now fed through a delay to shift the stop trigger relative to the PMT
 signal. The delay generator is placed directly
 |  | 
| 162 | Fri Apr  8 14:12:57 2022 | morning shift | DAQ | timing for h=1 | The timing for h=1 has been set up 
 The time window is now twice as large as
 |   | 
| 161 | Fri Apr  8 12:04:13 2022 | Ragan | Runs | NTCAP started | NTCAP is started for the data taking. 
 Carrier Frequency: 242.02 M
 |   | 
| 160 | Fri Apr  8 11:16:57 2022 | Kristian | Laser | Wavemeter | We changed the fiber to the wavemeter. The third fiber worked best and we could operate
 the WM at low exposure times, i.e., below
 |    | 
| 159 | Fri Apr  8 11:02:04 2022 | DW, YL, RSS, SL |  | Change h=2 to h=1 | After changing to h=1 The frequency manipulation #5: f=242.021487MHz
 (124th harmonic) [no bunching]
 |  | 