HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075
  Nuclear hyperfine mixing in 229Th89+, Page 5 of 12  Not logged in ELOG logo
ID Date Authordown Category Subject
  135   Thu Apr 7 10:10:31 2022 Ragan, Yuri, DanyalAcceleratorProblem in UNILAC
The power supply of the UNILAC magnet is broken. The repair will take up to 6-7 hours.
  96   Tue Apr 5 12:17:12 2022 Ragan, Rui-JiuDAQInstructions to start and stop NTCAP
Attached are the instructions to start and stop data taking using the NTCAP.
  154   Fri Apr 8 09:13:38 2022 Ragan, DanyalAcceleratorNo beam
Cathode is being changed at the ion source. So no beam for the moment.

Sergey has been contacted to change from two ion bunches to a single ion bunch in the ESR.
  151   Fri Apr 8 06:53:29 2022 RaganRunsNTCAP data taking
NTCAP is taking data since 07.04.2022 23:53:47

Carrier Frequency: 242.2 M
IQ Rate (S/s): 10 M
Reference level (dBm): -30

SC_2022-04-07_23-53-47
\IQ_2022-04-07_23-53-47
  155   Fri Apr 8 09:32:32 2022 RaganRunsNTCAP stopped
Since there is no beam, NTCAP is stopped.

Carrier Frequency: 242.2 M
IQ Rate (S/s): 10 M
Reference level (dBm): -30

SC_2022-04-07_23-53-47
\IQ_2022-04-07_23-53-47
  157   Fri Apr 8 09:39:04 2022 RaganRunsNTCAP started
Carrier Frequency: 242.2 M
IQ Rate (S/s): 10 M
Reference level (dBm): -30

SC_2022-04-08_09-39-33
\IQ_2022-04-08_09-39-33
  161   Fri Apr 8 12:04:13 2022 RaganRunsNTCAP started
NTCAP is started for the data taking.

Carrier Frequency: 242.02 M
IQ Rate (S/s): 10 M
Reference level (dBm): -30

SC_2022-04-08_12-04-28
\IQ_2022-04-08_12-03-50
  218   Tue Apr 12 14:11:52 2022 RaganDetectorsSideband in Schottky
> Sometimes we see a broad sideband at lesser Schottky frequencies to the high-intensity thorium beam.
> 
> Pic 1 shows the relative broad sideband on the left.
> 
> Pic 2 depicts the vanishing of the sideband after ~1-2 minutes.


These are not the sidebands. Maybe some short-lived fragments survive even after the scrapers are used?
  128   Thu Apr 7 05:44:40 2022 Pierre-Michel, RaganDAQNTCAP settings
Carrier Frequency: 244M
IQ Rate: 10M
reference Level: -30
RF - Attenuation: 40
IF - Attenuation: 19.9288

Masterpath p:\E142\sc
Masterpath p:\E142\IQ

Display: No Display

NTCAP data-taking is stopped at 5:44.

IQ_2022-04-07_02-40-05
SC_2022-04-07_02-40-05
  210   Mon Apr 11 14:45:11 2022 Paul, Konstantin, Sarper, DavidRunsAfternoon shift runs 11.04
We continue scan the new wavelength scan range is 322.41 - 322.00 nm



TimeSIS-intensitycooler-HVLMD-DAQ1 file nr LMD-DAQ2 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
14:45 1.9e9 209618 0189 7924 322.41 - 322.00 0.002 5s 9100
18:54 1.83e9 209616 0191 7926 322.41 - 322.00 0.002 5s 7300
19:34 1.7e9 209615 0192 7927 322.41 - 322.00 0.002 5s 7110
20:13 1.8e9 20961X 0193 7928 322.41 - 322.00 0.002 5s 6730
20:53 1.8e9 209614 0194 7929 322.41 - 322.00 0.002 5s 7550 During the scan the ecooler voltage changed to approximately 209613
21:43 1.7e9 209614 0195 7931 322.41 - 322.00 0.002 5s 7000
22:30 1.6e9 209612 0197 7932 322.41 - 322.00 0.002 5s 7300
23:10 1.4e9 209614 0198 7933 322.41 - 322.00 0.002 5s 6100 For this measurement, ESR_Ring went red, we realized only after completing the measurement. The sections went red are Dipole Correction Points (GE01KP17-18-19-20, 4 in total) @~23:45 and fixed @01:35...
01:52 1.6e9 209614 0199 7934 322.41 - 322.00 0.002 5s 7151
02:32 1.7e9 209616 0200 7935 322.41 - 322.00 0.002 5s 8368
03:22 1.8e9 209617 0201 7936 322.41 - 322.00 0.002 5s 7005
04:01 1.9e9 209616 0202 7937 322.41 - 322.00 0.002 5s Ecooler voltage increased 4 volts during the run
  138   Thu Apr 7 14:04:36 2022 Paul IndelicatoGeneralno beam until 17:00
10:10  There is a problem with the UNILAC. 
The repair will take several hours. (4 hrs?) 

14:00  We just enquired about the status and when beam could be back. 
The current estimate is 17:00.

More work on laser aligment is required. 
Estimated time: 1 hour
  203   Sun Apr 10 22:47:05 2022 Patrick, Volker, Prannay, Danyal, Alexandre, Sebastian, KristianRunsRuns night shift 10.04 + morning shift 11.04
These are the measurement runs of the night shift (10/11.04.).

Wavelength range is still 322.81 - 322.40 nm.


TimeSIS-intensitycooler-HVLMD-DAQ1 start-endLMD-DAQ2 start-endscan range(nm)step width(nm)dwell time(s)particles countedcomments
23:05 1.75e92096200165 - 01657901-7901322.81 - 322.400.0025s8500
23:57 1.?e92096200166 - 01667902-7902322.81 - 322.400.0025s8500The HV of PMT south was changed from 2.5kV to 3kV
00:35 1.4e92096200167 - 01677903-7903322.81 - 322.400.0025s4100
01:18 1.75e92096200168 - 01687904-7904322.81 - 322.400.0025s4400
01:58 1.4e92096200169 - 01697905-7905322.81 - 322.400.0025s7700 The ESR went red after this run. The on-call service was called because of some power supply failure, ETA: 45min.
04:12 1.75e92096200171 - 01717906-7906322.81 - 322.400.0025s7600 With the start of this run, the wavemeter, labview and the python script were restarted. The python script was slightly adjusted.
04:50 1.6e92096200172 - 01727907-7907322.81 - 322.400.0025s8300
05:31 1.6e92096190173 - 01737908-7908322.81 - 322.400.0025s8100
06:09 1.6e92096150174 - 01747909-7909322.81 - 322.400.0025s 8000
06:52 1.8e92096150175 - 01757910-7910322.81 - 322.400.0025s8800 at 07:08 the cooler voltage jumped from 209615 V to 209619 V
07:30 1.9e92096190176 - 01767911-7911322.81 - 322.400.0025s forgotten at 07:50 the cooler voltage jumped from 209619 to 209610 V and back again at to 209619 V
08:18 1.8e92096190177 - 01777912-7912322.81 - 322.400.0025s 9100 08:47 the cooler voltage jumped from 209618 to 209614 V and back again at to 209618 V
08:55 1.75e92096190178 - 01787913-7913322.81 - 322.400.0025s 8300
09:36 1.6e92096190179 - 01797914-7914322.81 - 322.400.0025s 8194


The SIS intensity is taken directly before injection to ESR. Not the SIS peak intensity as in yesterday's table.
  232   Thu Apr 14 22:44:40 2022 Patrick, Simon, Danyal, MaxRunsRuns night shift 14./15.04.
Runs of the night shift. The wavelength range is 320.62 - 320.10 nm.

TimeSIS-intensitycooler-HVLMD-DAQ2 file nr LMD-DAQ1 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
22:38 9.5e8 209621 0305 8018 320.62 - 320.10 0.002 5s 5000 laser scan was started 1 min late
23:38 9.8e8 209622 0306 8019 320.62 - 320.10 0.002 5s 5550
00:32 1.0e9 209621 0307 8020 320.62 - 320.10 0.002 5s 4000 After ~4000 counted particles (second scan, 1:04 am) the e-cooler went off.
01:21 1.1e9 209622 0308 8021 320.62 - 320.10 0.002 5s 6700
02:12 1.2e9 209623 0309 8022 320.62 - 320.10 0.002 5s 6400
03:03 1.1e9 209624 0310 8023 320.62 - 320.10 0.002 5s 5500
03:55 1.3e9 209622 0311 8024 320.62 - 320.10 0.002 5s 7700
04:47 1.2e9 209622 0312 8025 320.62 - 320.10 0.002 5s 5300
05:36 1.2e9 209620 0313 8026 320.62 - 320.10 0.002 5s 6666
06:25 1.2e9 209619 0314 8027 320.62 - 320.10 0.002 5s 6500 change of shift crew (Danyal & Max)
07:16 1.2e9 209618 0315 8028 320.62 - 320.10 0.002 5s 5230
08:13 1.2e9 209620 0316 8029 320.62 - 320.10 0.002 5s 6600
09:04 1.1e9 209619 0317 8030 320.62 - 320.10 0.002 5s 6660
09:54 1.2e9 209619 0318 8031 320.62 - 320.10 0.002 5s 5950
10:49 1.1e9 209619 0319 8032 320.62 - 320.10 0.002 5s 6580
11:38 1.1e9 209617 0320 8033 320.62 - 320.10 0.002 5s 5380
  236   Sat Apr 16 04:19:05 2022 Patrick, Simon, Alex, SarperRunsRuns night + morning shifts 16.04.
Runs of the night shift 16.04. after changing the wavelength range. The new range is 320.12 - 319.859 nm. The step size was decreased from 0.002 nm to 0.001 nm.
The goal was to have the same number of scans as before (261), however, the scan range in the labview program could not be set accordingly. We decided to go with 262 scans after the first run.


TimeSIS-intensitycooler-HVLMD-DAQ2 file nr LMD-DAQ1 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
04:24 1.28e9 209616 0338 8051 320.12 - 319.86 0.001 5s 6750 This run had only 260 scans
05:18 1.20e9 209615 0339 8052 320.12 - 319.859 0.001 5s 6300 First run with 262 scans
06:09 1.36e9 209615 0340 8053 320.12 - 319.859 0.001 5s 6910 laser scan started 2 min late at 650 counts
07:03 1.24e9 209615 0341 8054 320.12 - 319.859 0.001 5s 6330
07:59 1.23e9 209615 0342 8055 320.12 - 319.859 0.001 5s 5712
08:51 1.1e9 209615 0343 8056 320.12 - 319.859 0.001 5s 4380
09:44 1.28e9 209615 0344 8057 320.12 - 319.859 0.001 5s 5135
10:39 1.25e9 209615 0345 8058 320.12 - 319.859 0.001 5s 5860
11:30 1.2e9 209615 0346 8059 320.12 - 319.859 0.001 5s 6500
12:22 1.23e9 209618 0347 8060 322.41 - 322.00 0.002 5s 5200 Laser wavelength scan range is changed to 322.41 - 322.00 nm and increment to 0.002 nm.
13:04 1.2e9 209616 0348 8061 322.41 - 322.00 0.002 5s 4411
13:50 1.2e9 209616 0349-0351 8062-8063 322.41 - 322.00 0.002 5s 10651 last scan / 10 loops ~ 3 hours of scan -- Ecooler failed, realized at 16:05 we were on loop8, laser is turned off at 16:10
  59   Fri Apr 1 23:12:37 2022 PatrickDetectorsScraper positions "only primary beam"

Scraper positions where there is only primary beam for detector tests. Use only one outer and one inner scraper at the same time.
Move detectors out before new beam!

outer:
GE02DD2_G: 0mm
GE01DD2AG: -10mm

inner:
GE01DD2IG: 40mm
  117   Wed Apr 6 22:29:55 2022 PatrickAcceleratorECooler voltages
ECooler voltages:

06.04:
22:30: 209676 V
00:14: 209647 V

07.04.:
00:46: 209647 V
04:06: 209648 V
  118   Thu Apr 7 00:15:11 2022 PatrickLaserLaser timing adjusted
We have adjusted the laser timing using PMT-middle. Bunching freq. is 3.90362 MHz.

PD NO: 7.79
PD SO: 43.37
mean: 25.08

PMT middle: 25.02

Delta = 0.6 bins * 3.3 ns = 0.2 ns

New injection:
PMT middle: 25.48 / 101.91
ParDet south: 74.31 / 151.31

ParDet south - PMT middle (furthest / closest distance) = 161.1 ns / 91.1 ns
  120   Thu Apr 7 01:19:05 2022 PatrickLaserLaser scanning
We did some laser scans. The wavemeter shows spikes during scans. This may be just while the frequency changes. See picture.
  122   Thu Apr 7 03:06:15 2022 PatrickDAQDAQ file sizes
The file sizes of DAQ1 (229Thor) and DAQ2 (229Th, "Carstens DAQ") are different.
During 20min of laser scanning DAQ1 saves 4 files while DAQ2 saves 2 files which was 3.3 GB and 2 GB, respecively.
The file sizes of DAQ2 should always be greater than those of DAQ1, because of extra ADC data!

The problem seems to be solved after the recabling ID: 125.
  124   Thu Apr 7 03:44:21 2022 PatrickDAQMeasurement procedure
Measurement procedure


- The laser hits the screen 'NO' (atppc017) right side of the burn spot
- Be ready to start a laser scan
- Scan laser goes into wavemeter!
- Have mbs connected
- Have go4 connected

Preparation done

- 'open file (...)' for DAQ1 & DAQ2
- request a new beam
- check scraping
- 'sta ac' for DAQ1 & DAQ2
- start laser scan

laser scan started

- 'sh ac' for DAQ1 & DAQ2
- check that acquisition is RUNNING and file is OPENED
- fill in table information in the ELOG.

laser scan complete

- 'sto ac' for DAQ1 & DAQ2
- 'close file'
- check if preparation is still fulfilled
- repeat from Preparation done
ELOG V3.1.5-fc6679b