HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  nuclear two-photon decay, Page 1 of 12  Not logged in ELOG logo
Entry  Thu Jul 1 14:47:15 2021, Yury, Helmut, Accelerator, added high Brho scrapers ESR-scraper-overview.jpgscrapers-used.JPG
So far only scrapers for low Brho were used:
  GE01DS_HI = -58mm (arc from inside) and
  GEEXDS2HA = -11.2 (straight from outside)
Entry  Sun May 9 13:53:07 2021, Yuri, Wolfram, Andrew, Liliana, Calibration, Change of energy: Back as before Screenshot_2021-05-09_13-59-36.png
After looking at the spectrum it was concluded that the same isotopes, and no more, could be identified. 
Now we change the energy back to 441.7 MeV/u and will open the scrappers to see if Mn comes in. 
Entry  Sat May 8 17:29:54 2021, Yuri, Sergey, Wolfram, Michael, Shahab, Runs, recording Kr decay measurement on NTCAP 
Uc = 250mA
decay Kr 78, 476 MeV/u
Entry  Wed Jun 30 13:57:14 2021, Yuri, Sergey, Accelerator, sextupoles + scraper positions photo_2021-06-30_14-09-08.jpgphoto_2021-06-30_14-02-25.jpg
After setting up on 70Se
Sextupoles were adjusted to optimize the resolution of the 70Se peak. Set values are in the ESR logbook.
The SIS energy was shifted up to increase the number of 70Se.
Entry  Wed Jun 30 09:04:50 2021, Yuri, Markus, Accelerator, Status 
1) Over night the source was conservated. It is being restarted now.
2) The approximated amount of Gas in this bottle shall allow for running until tomorrow morning (~24 h). There is still another bottle in reserve (1 l)
and one reserve from GANIL (0.5 l).
Entry  Thu May 6 21:26:02 2021, Yuri et al., Accelerator, Energies 
gamma_t = 1.3955
Br(72Ge) corresponds to 6.79575 Tm
E (Kr) at Br(72Ge) = 392.9 MeV/u
Entry  Tue May 4 13:26:40 2021, Yuri, Simulations, Expected spectrum 72Ge 
A       Z      M/q                Int    difference in kHz@245MHz
68 30 2.263614752 35 -933.1
70 31 2.255131564 124 -457.0
Entry  Fri May 7 09:56:43 2021, Yuri, Calibration, Identification Verification 
With closed scrapers there are only a few weak lines.
Open temporarily all scrapers in the ESR to write down the frequencies. 
Entry  Fri May 7 09:58:04 2021, Yuri, Accelerator, Setting up KO extraction for Caves 
SIS optimisation requires us to stop. Only sporadic shots.
Entry  Fri May 7 10:05:06 2021, Yuri, Accelerator, E02DS3HG does not drive 
E02DS3HG stays at -35 mm and does not react
Entry  Fri May 7 10:46:40 2021, Yuri, Accelerator, GE02DS3HG 
The scraper is blocked at -10 mm and -unfortunately- blocks the beam in the ESR. Uli Popp is taking care.
Entry  Fri May 7 14:06:02 2021, Yuri, Accelerator, SIS kicker failure 
 
Entry  Fri May 7 16:09:50 2021, Yuri, Accelerator, Stop, change of sextuple settings 
 
Entry  Sat May 8 11:42:21 2021, Yuri, Accelerator, KPs 
EO1KP03 was on = -44.9 A
E01KP05 was off, now is on = 3.67 A
The beam is on the right frequency, but the width is still very broad.
Entry  Sun May 9 14:19:44 2021, Yuri, Accelerator, Spectrum 
We accept larger m/q values than we like to. m/q(low) cut ~ 2.08. Decrease ESR energy from 369.2 -> 368.4 MeV/u
frequencies shifted by -37.5 kHz (at 60 MHz)
Entry  Fri Jun 25 21:47:24 2021, Yuri, Analysis, Identification Spectrum_possible_ID.pngID_2nd_Part.jpg
Attached are two files with a proposed particle identification.
Different colors indicate different harmonic numbers
Entry  Wed Jun 30 08:59:37 2021, Yuri, Accelerator, 70Se setting 
X(9Be)=1.815 g/cm2 (adjusted in primary beam setting)

Gamma_t=1.3956
Entry  Fri Jul 2 13:10:00 2021, Yuri, Accelerator, Scrapers 
12:46 moved the TOF detector scraper back to -11 mm
Entry  Fri Jul 2 16:14:17 2021, Yuri, Accelerator, Scrapers 4 72Br 1C28A49A-5FA1-4A81-8675-3ED9660FD793.png
Starting 15:15
The scrapers are moved very much close to each other to eliminate all background particles and leaving basically single ions injected for 72Br. Do not
wonder, this means that also many empty files are created.
Entry  Fri Jul 2 20:33:44 2021, Yuri, Accelerator, 70Se setting with closed scrapers 
We tune back to 70Se.
The scrapers stay closed at EEXDS2HA=0 mm, EEXDS1HG=+5 mm
"Single"-particle run
ELOG V3.1.5-fc6679b