ID |
Date |
Author |
Category |
Subject |
Text |
|
116
|
Sun May 9 23:24:49 2021 |
Helmut, Wolfram, Yuri | Accelerator | scraper optmisation for 72Ge | We tried the scrapers a bit, because right
of peak some background appeared.
|
|
27
|
Fri May 7 03:44:55 2021 |
Helmut Weick | Accelerator | scraper optimisation | Opened TE4 slits again to +/-10mm.
Then we tried different scrapers:
|
|
117
|
Sun May 9 23:28:25 2021 |
Kanika, Alex, Wolfram, Helmut, Shahab | Runs | return with the Ge setting of the last night | starting filenames:
E143-410MHz-2021.05.09.23.28.24.018.tiq
|
|
77
|
Sat May 8 17:29:54 2021 |
Yuri, Sergey, Wolfram, Michael, Shahab | Runs | recording Kr decay measurement on NTCAP | Uc = 250mA
decay Kr 78, 476 MeV/u
|
|
111
|
Sun May 9 19:03:02 2021 |
Rodostina, Oliver, Wolfram, Helmut, Yuri, Shahab | Runs | quadrupoles were down, fixed. | |
|
174
|
Thu Jul 1 18:49:59 2021 |
Shahab | Runs | possible isomer? | |
|
88
|
Sun May 9 02:32:58 2021 |
Jacobus, Shahab | Runs | possible 52-Mn isomer | the intensity of the line on the left side
is so high, it is difficult to see the isomers
in the middle as can be seen in the auto |
|
29
|
Fri May 7 03:51:56 2021 |
Shahab | Analysis | peak frequencies | a reference schematic of the peaks on 410
MHz (211th harmonic) and 245 MHz (126th harmonic) |
|
118
|
Sun May 9 23:32:24 2021 |
Helmut | Accelerator | parammodi saves | Here are parammodi saves for TE-line and ESR
for all four fragment settings:
For the first run of 72Ge (7.May) I do not |
8x |
80
|
Sat May 8 21:08:13 2021 |
Helmut, Sergey, Shahab, Wolfram, Yuri | Accelerator | optimisation of sextuples | The optimisation of sextuples is finished.
Record a few files. |
|
94
|
Sun May 9 05:38:29 2021 |
Iris, Chris G. | Analysis | offset btw png and tiq files from server? | This might have been answered before but I
looked at one png file and one tiq file from
the same run that was stored on the server. |
|
95
|
Sun May 9 05:54:11 2021 |
Ragan | Analysis | offset btw png and tiq files from server? | This is due to the 50% trigger setting in
the spectrum analyzers )) |
|
122
|
Mon May 10 00:41:20 2021 |
Chris C | Accelerator | no beam | Beam gone ~0:34.
Working on getting it back.
Back in business ~0:57. |
|
50
|
Fri May 7 17:02:51 2021 |
Kanika, Sergey, Yuri, Wolfram, Michael, Shahab | Runs | new sextupole setting 2 | There is new sextupole settings, but the scrapers
remain like last night (Helmut setting last
night.) |
|
49
|
Fri May 7 16:17:21 2021 |
Sergey, Yuri, Wolfram, Shahab | Runs | new sextupole setting | new sextupole setting, isomer not visible
yet. |
|
205
|
Fri Jul 2 11:44:25 2021 |
Helmut, Yuri | Accelerator | move scrapers to see effect on unknown lines | We close the arc inside and straight section
inside scrapers to narrow and cut the 70Se
line.
|
|
21
|
Fri May 7 01:07:27 2021 |
Helmut Weick | Analysis | maybe frequency ID | We think we see the frequency range of A/q=2.25
at 243.1 MHz.
This would correspond to L=108.2m and E=386.4 |
|
142
|
Tue Jun 29 21:15:01 2021 |
Kanika, Shahab | Runs | lost beam problem Unilac | cooling water in UNILAC is out |
|
126
|
Mon May 10 03:37:53 2021 |
Chris C | Analysis | isomer? or wishful thinking? | They are not easy to find, but we do occasionally
see what might be the isomer. |
|
178
|
Thu Jul 1 19:34:11 2021 |
Shahab | DAQ | increase factor 4 in power for 410 | increase factor 4 in power for 410
|
|