Entry  Sat Jul 3 06:55:57 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000761
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003720
Entry  Fri Apr 23 13:47:55 2021, Jan Glorius, Collaboration, experiment proposal ESR_Two-Photon_proposal_final.pdf
 
Entry  Thu May 6 14:28:32 2021, Helmut Weick, Calibration, Be target thickness calibration -> 1839 mg/cm^2 
Injection was optimized before with Cu-40 mg/cm^2 stripper.
This reduces energy of 78Kr from 370 MeV/u -> 386.52 MeV/u.
To keep the same ESR injetion the SIS energy was raised with Be 10mm tatget.
Entry  Fri May 7 09:56:43 2021, Yuri, Calibration, Identification Verification 
With closed scrapers there are only a few weak lines.
Open temporarily all scrapers in the ESR to write down the frequencies. 
Entry  Sat May 8 10:51:41 2021, Akash, Nic, Jelena, Zsolt, Calibration, ESR settings seem different Screenshot_2021-05-08_at_10.50.23.png
Settings don't look the same...so we are not yet writing files unless sure.
Entry  Sun May 9 13:53:07 2021, Yuri, Wolfram, Andrew, Liliana, Calibration, Change of energy: Back as before Screenshot_2021-05-09_13-59-36.png
After looking at the spectrum it was concluded that the same isotopes, and no more, could be identified. 
Now we change the energy back to 441.7 MeV/u and will open the scrappers to see if Mn comes in. 
Entry  Fri May 7 01:07:27 2021, Helmut Weick, Analysis, maybe frequency ID frequencies.JPG
We think we see the frequency range of A/q=2.25 at 243.1 MHz.
This would correspond to L=108.2m and E=386.4 MeV/u (gamma_t = 1.3955) at h = 126.
Path length is a bit short, for L=108.4m it should be 370.6 MeV/u. 
Entry  Fri May 7 03:51:56 2021, Shahab, Analysis, peak frequencies New_Doc_6_1.jpgNew_Doc_6_2.jpg
a reference schematic of the peaks on 410 MHz (211th harmonic) and 245 MHz (126th harmonic)
Entry  Fri May 7 06:53:56 2021, Akash, Liliana, Analysis, Some plots 6x
Some plots of statistics up to now
Entry  Fri May 7 07:02:33 2021, Guy Leckenby, Analysis, Online Monitoring Plots E143_spec_1sec.png
In compliment to Liliana's plots, this is the summed spectra I calculated from 0338 to 0507.
Entry  Fri May 7 08:04:22 2021, Carlo Bruno, Desislava Kalaydjieva, Analysis, 7:00 - 14:00 analysis shift 15x
(See
https://triumfoffice365-my.sharepoint.com/:w:/g/personal/dillmann_triumf_ca/Eb_LCp7yTx5Bgc8TO8khJmEBWeS-ycdPRnG02wQout-fgQ?rtime=3n3A3xMR2Ug
for remote shifter instructions. To be updated/corrected by the experts)
Entry  Fri May 7 20:28:32 2021, Kanika, Michael, Shahab, Analysis, Some pictures from the 410 detector 9x
some pics.
Entry  Sat May 8 08:16:08 2021, Akash, Nic, Jelena, Zsolt, Analysis, Night shift analysis 16x
(Jelena has analysed these data files)

E143_245MHz_2021.05.08.00* (-s 5.0 -t 0.5)  (2021.05.08.09.01.11.png)
Entry  Sun May 9 05:38:29 2021, Iris, Chris G., Analysis, offset btw png and tiq files from server? comp-116.png
This might have been answered before but I looked at one png file and one tiq file from the same run that was stored on the server. There seems to be an
offset of 2.2 s. The png file from the server (right) shows the injection at ~5s, whereas when I look at the tiq file in the GUI (left), the injection
is at ~2.8 s???? Is the looper introducing this offset?
    Reply  Sun May 9 05:54:11 2021, Ragan, Analysis, offset btw png and tiq files from server? 
This is due to the 50% trigger setting in the spectrum analyzers ))
Entry  Sun May 9 05:56:29 2021, Iris, Chris G., Jacobus, Michele, Analysis, Not_52Mn spectra added up Not_52Mn_245MHz_May09_1-2am.pngNot_52Mn_245MHz_May09_1-2am.root
Attached is a summed spectra of all files taken between 1:17am and 1:59am (on the 245 MHz detector).

python3 e143_analyzer.py -s 5.1 -t 0.5 /home/dillmann/E143/e143-scripts/sparc-daq-02.gsi.de/E143-245MHz/E143-245MHz-2021.05.09.01.* -o Not_52Mn_245MHz_May09_1-2am
Entry  Sun May 9 06:34:37 2021, Iris, Chris G., Jacobus, Michele, Analysis, Runs 2-3am Not_Mn52 Not_52Mn_245MHz_May09_2-3am_s0_1_t8_0.pngNot_52Mn_245MHz_May09_2-3am_s0_1_t8_0.rootNot_52Mn_245MHz_May09_2-3am_s5_1_t0_5.pngNot_52Mn_245MHz_May09_2-3am_s5_1_t0_5.root
Summed up runs on the 245 MHz detector between 2-3am (computer time).
One has -s 0.1 -t 8.0
the other -s 5.1 -t 0.5
    Reply  Sun May 9 07:16:47 2021, Iris, Chris G., Jacobus, Michele, Analysis, Runs 3-4am Not_Mn52 Not_52Mn_245MHz_May09_3-4am_s0_1_t8_0.rootNot_52Mn_245MHz_May09_3-4am_s0_1_t8_0.png
Summed up runs on the 245 MHz detector between 3-4am (computer time).
-s 0.1 -t 8.0
Entry  Sun May 9 12:53:01 2021, Desislava Kalaydjieva, Taka Yamaguchi, Analysis, Analysis, Morning shift, 9 May 9x
For the whole morning shift there were no significant changes in the spectra.

Some of the obtained histograms are attached below. 
Entry  Sun May 9 17:39:21 2021, Guy, Analysis, Comparison between 72Ge: 7th 19h vs 8th 21h 410MHz-05.09.19h-t11ms-sMontage.png410MHz-05.08.21h-t11ms-sMontage.png
Following Xiangcheng Chen's analysis, I analysed 11 ms time slices separated by 25 ms to see the evolution of the potential isomer across the injection.

Attachment 1: Data from May 7th 19h-20h. -t 11ms progression from -s=5 to -s=5.175