  Nuclear hyperfine mixing in 229Th89+ 2025, Page 1 of 4  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Category Subject
  Draft   Sat Jun 28 15:28:22 2025 Carsten., Uwe RunsRuns with new scan range
22:10 SIS Trafo GS09DT scale was changed to 4e8 (not just the lassie monitor)
23:50 Ausfall ESR: GE01 KP01 bis KP05 und KP22 bis KP24; Korrekturelement: GE02KX6 und GE01KX2; beam loss during measurement
01:45 reser press air Scrapers: GE02DD2_G (sc8,11); GE02DS03HG(sc7,8,11); GE01DD2IG(was sc7,10,11)(now7,8,11)
Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position mesytec rate ok TE slits comments
15:25 >20000 2.5e9 30 - - - 260 234 550.610 - 548.110 501 15 1 yes yes TE slits -7 +7 detector started too late
15:52 15200 2.5e9 30 - - - 261 235 550.610 - 548.110 501 15 1 yes yes TE slits -7 +7 SIS injection fluctuating
16:09 6000 3.3e9 30 - - - 262 236 550.610 - 548.110 501 15 1 yes yes TE slits -7 +7 accumulation curve in ESR much flatter
16:31 5800 3.0e9 30 - - - 264 237 550.610 - 548.110 501 15 1 yes yes TE slits -7 +7 data not in online DAN; lmd-file: DAQ2_0263.lmd is empty
16:47 10000 3.0e9 30 - - - 265 238 550.610 - 548.110 501 15 1 yes yes TE slits -7 +7 okay
17:10 15500 3.0e9 35 - - - 266 239 550.610 - 548.110 501 15 1 yes yes TE slits -7 +7 okay
17:45 16000 3.2e9 35 - - - 267 240 550.610 - 548.110 501 15 1 yes yes TE slits -7 +7 okay
18:11 4800 3.0e9 40 - - - 268 241 550.610 - 548.110 501 15 1 yes yes TE slits -6 +6 data not in online DAN
19:00 4650 3.0e9 40 - - - 269 242 550.610 - 548.110 501 15 1 yes yes TE slits -9 +5.5 SIS ions low for first 8 to 10 injections
19:40 14900 3.0e9 40 - - - 270 243 550.610 - 548.110 501 15 1 yes yes TE slits -9 +5.5 3-5 empty shots during filling
19:56 14800 2.5e9 40 - - - 271 244 550.610 - 548.110 501 15 1 yes yes TE slits -9 +5.5 3-5 empty shots during filling
20:10 5600 2.3e9 40 - - - 272 245 550.610 - 548.110 501 15 1 yes yes TE slits -9 +5.5 3-5 empty shots during filling; SIS -> ESR injections 1-3x10**-9 particles variation; accelerator stopped after half filling of ESR; took data for measurement
2155: 14300 2.5e9 35 - - - 273 246 550.610 - 548.110 501 15 1 yes yes TE slits -9 +5.5




17:11 HHT access
17:20 beam back, but problems with SIS intensity
17:35 intensity good, again. 3x10**9 particles in SIS |-
18:30 SIS intensity dropped to 1x10**8 particles
18:45 SIS intensity recovered to 3.75x10**9 particles

Starting from 18:45 slits are set asymmetric:
The dipole magnet TE4MU1 which is in front of our TE slit pair turns to the right. Thus, lower momentum ions are also on the right side. 229Pa89+ has a higher Z=91 than 229Th89+ (Z=90).
Therefore, in the thick target Z=91 , Pa looses more energy than 229Th. With the asymmetric setting we try to further minimize Pa contaminants.
20:05 HHT access
20:15 SIS dipol failure; 1-2h no beam expected; on-call-technical-service is informed
21:10 beam is back. SIS dipole / power supply a fuse needed to be exchanged; we leave the beam for 30min to FRS exclusively
  70   Sat Jun 28 06:29:58 2025 Stefan, Simon, KonstantinRunsMorning shift 28.06.
6:30 Problem with ion source, on-call service is called
7:30 There is a short in the ion source and it needs to be changed. Expected down time about 2h
10:30 Ion source was successfully changed, but while ramping up the source a power supply failed. Next on-call service is on their way to GSI.
13:00 ions are back


We changed the dye as the laser intensity was quite low. That didnt help, so Konstantin came in to change the dye cell. That did help.

No scans during morning shift.
  69   Fri Jun 27 22:14:35 2025 Anton, Finn, CarstenRunsRuns night shift 27.06. 28.06
22:10 SIS Trafo GS09DT scale was changed to 4e8 (not just the lassie monitor)
23:50 Ausfall ESR: GE01 KP01 bis KP05 und KP22 bis KP24; Korrekturelement: GE02KX6 und GE01KX2; beam loss during measurement
01:45 reser press air Scrapers: GE02DD2_G (sc8,11); GE02DS03HG(sc7,8,11); GE01DD2IG(was sc7,10,11)(now7,8,11)
Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position mesytec rate ok comments
22:08 17000 2.5e9 30 104524 104527 104528 205 233 551.91 - 549.41 501 15 1 yes yes TE slits -6 +6
22:27 7200 4e8 30 104524 104527 104528 206 234 551.91 - 549.41 501 15 1 yes yes TE slits -6 +6 ! small peak on right side, not good scraped
23:19 6000 2.5e9 30 104524 104527 104528 207 235 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
23:35 15000 2.3e9 30 104524 104527 104528 208 236 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
23:47 00 2.3e9 30 104524 104527 104528 209 237 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \ scan not compete, beam loss during measurement
00:17 6200 2.7e9 30 104524 104527 104528 210 238 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
00:45 6400 2.6e9 30 104524 104527 104528 211 239 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \small peak on right side, badly scraped
01:00 5100 2.75e9 30 104524 104527 104528 212 240 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \small peak on right side, badly scraped
01:15 5200 2.6e9 30 104524 104527 104528 213 241 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \small peak on right side, badly scraped
01:45 4900 2.3e9 30 104524 104527 104528 214 242 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \bigger peak on right side, badly scraped
01:58 12600 2.25e9 30 104524 104527 104528 215 243 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \small peak on right side, badly scraped
02:13 12000 2.4e9 30 104524 104527 104528 216 244 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \small peak on right side, badly scraped
02:28 13900 2.45e9 30 104524 104527 104528 217 245 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \small peak on right side, badly scraped
02:48 17000 2.45e9 30 104524 104527 104528 218 246 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
02:58 13500 2.45e9 30 104524 104527 104528 219 247 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
03:13 14900 2.5e9 30 104524 104527 104528 220 248 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped
03:27 5200 2.5e9 30 104524 104527 104528 221 249 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped
03:42 13000 2.5e9 30 104524 104527 104528 222 250 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped
04:08 14300 2.9e9 30 104524 104527 104528 223 251 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
04:23 15400 2.9e9 30 104524 104527 104528 224 252 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
04:38 13800 2.9e9 30 104524 104527 104528 225 253 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped
05:03 12800 2.5e9 30 104524 104527 104528 226 254 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped
05:23 3900 2.6e9 30 104524 104527 104528 227 255 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped
05:38 11200 3.e9 30 104524 104527 104528 228 256 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
05:53 3900 2.5e9 30 104524 104527 104528 229 257 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped
06:08 11700 low.intensity 30 104524 104527 104528 230 258 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7 \badly scraped

During whole night shift scraping right peak did not work consistently. Remaining intensity varied from similar peak height compared to torium down to about 20%.
  68   Fri Jun 27 14:23:39 2025 Nils, Wilfried, Carsten, JulianRunsRuns afternoon shift 27.06.
15:30 We have a break due to an issue at UNILAC (quadrupole failed). Also radiation safety interlock was triggered at the fragment separator. This also pushed a faradaycup into the ESR (GE01DC3VP).
Just before the issue during the last bunching, the peak was misaligned to the marker in the Schottky. The marker was sitting on the right flank. So the electron-cooled 229Th did not match with the bunching frequency anymore. We are preparing to adjust the cooler voltage to fix this. For some reason the frequency recovered and is back to its original position. However, our accumulations do not seem to work as well as before, we stagnate much earlier and at a much lower level.

15:50 Beam is back, Carsten is still investigating the drop in intensity we saw before the UNILAC failure.

17:15 TE slits were on -8 and +8, opening to -11 and +11, no change to acquisition pattern, something is still wrong

18:00 We were locked out by HHT people for 30+ mins

18:27 We had to call in ESR support

Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position mesytec rate ok comments
14:24 15800 2.74 e9 30 104524 104527 104528 196 224 551.91 - 549.41 501 15 1 yes yes Carsten optimizing beam at HKR with ESR colleagues
14:24 6800 1.16 e9 30 104524 104527 104528 197 225 551.91 - 549.41 501 15 1 yes yes Carsten is back in measurement hut
16:30 1100 1.1 e9 40 104524 104527 104528 198 226 551.91 - 549.41 501 15 1 yes yes Searching for reason for small particle number
17:00 1200 0.5 e9 30 104524 104527 104528 199 227 551.91 - 549.41 501 15 1 yes yes
19:57 7800 1e9 30 104524 104527 104528 200 228 551.91 - 549.41 501 15 1 yes yes Restarting some things at ESR
20:16 6800 1.5e9 30 104524 104527 104528 201 229 551.91 - 549.41 501 15 1 yes yes Restarting some things at ESR
20:41 7200 1.5e9 30 104524 104527 104528 202 230 551.91 - 549.41 501 15 1 yes yes Restarting some things at ESR
21:28 6000 2.65e9 30 104524 104527 104528 203 231 551.91 - 549.41 501 15 1 yes yes
21:47 6600 2.7e9 30 104524 104527 104528 204 232 551.91 - 549.41 501 15 1 yes yes
22:08 17000 2.5e9 30 104524 104527 104528 205 233 551.91 - 549.41 501 15 1 yes yes TE slits -7 +7
  67   Fri Jun 27 11:21:25 2025 Esther, KonstantinDAQTiming
We cross-checked the timing. Laser pulse is detected at bins 136 (PD-North) and 171 (PD-south), respectively. Therefore, the laser puls is in the electron cooler at 153.5. The revolution period corresponds to 3e8Hz / 1.54315MHz = 194. 
The ion bunch must travel 2.5m more than the half of the circumference (108.3m). Taking this into account, the ion bunch must be detected (0.5 + 2.5 / 108.3) * 194 = 101.5 bins later (meaning less) than 153.5.
Finally, we are happy that the timing is still perfect, since the ion bunch arrives at 52. 
  66   Fri Jun 27 06:55:45 2025 Esther. KonstantinLaserLaser-ion overlap
We cross-checked the laser-ion superposition by using the T-scrapers. We did it only after the scans in order to do not change the duty cycle by much. Attachements are in the order of the measurements compiled in the table.

motorion beam position (mm) from inside
GECEDS1VU -0,5
GECEDS1HA -4
GECEDS2VU 0.9
GECEDS2VU 0


Still looks fine to us.
Attachment 1: 2025-06-27_06-52-01-807.png
2025-06-27_06-52-01-807.png
Attachment 2: 2025-06-27_07-12-27-135.png
2025-06-27_07-12-27-135.png
Attachment 3: 2025-06-27_07-32-28-599.png
2025-06-27_07-32-28-599.png
Attachment 4: 2025-06-27_07-51-52-620.png
2025-06-27_07-51-52-620.png
  Draft   Fri Jun 27 06:13:02 2025 Esther, KonstantinRunsEarly shift - data taking
Notes:
1. TE slits at -10 and +10
2. SIS intensity unstable until about 9:00 after that it became much more stable
3. brief interruption between 09:30 and 10:03 due to interlock issue at SIS

Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position mesytec rate ok comments
06:15 16300 1.5-3.5 e9 30 104522 104526 104526 172 199 551.91 - 549.41 501 15 1 yes yes
06:30 13500 1.5-3.5 e9 30 104522 104526 104526 173 200 551.91 - 549.41 501 15 1 yes yes
06:44 4000 1.5-2 e9 30 104522 104526 104526 174 201 551.91 - 549.41 501 15 1 yes yes beam scraped vertically with scraper 1 after end of laser scan (see entry 66), scraper left in but tilted to allow for injection
07:05 14800 2-3.5 e9 30 104522 104526 104526 175 202 551.91 - 549.41 501 15 1 yes yes beam scraped horizontally with scraper 1 after end of laser scan (see entry 66), scraper 1 moved back out
07:25 14000 1.1-2.6 e9 30 104522 104526 104526 176 203 551.91 - 549.41 501 15 1 yes yes beam scraped horizontally with scraper 2 after end of laser scan (see entry 66), scraper 2 left in but tilted to allow for injection
07:44 4200 1-2.5 e9 30 104522 104526 104526 177 204 551.91 - 549.41 501 15 1 yes yes beam scraped horizontally with scraper 2 after end of laser scan (see entry 66), scraper 2 moved back out
08:12 5700 1-2.5 e9 30 104522 104526 104526 178 205 551.91 - 549.41 501 15 1 yes yes !!file in DAQ1 not closed after end of scan!!; ~5 injections missing because nothing came from SIS
08:27 16000 1.5-3 e9 30 104522 104526 104526 178 206 551.91 - 549.41 501 15 1 yes yes !!file in DAQ1 still open from last scan!!
08:44 11700 1.5-3 e9 30 104522 104526 104526 179 207 551.91 - 549.41 501 15 1 yes yes
09:00 15600 2.6-3 e9 30 104522 104526 104526 180 208 551.91 - 549.41 501 15 1 yes yes
09:24 6500 2.8 e9 30 104522 104526 104526 181 209 551.91 - 549.41 501 15 1 yes yes
10:13 14600 2.2 e9 30 104522 104526 104526 182 210 551.91 - 549.41 501 15 1 yes yes
10:31 183 211 BAD FILES: ESR not stopped in SC9, injection during laser scan
10:39 14500 2.6 e9 30 104522 104526 104526 184 212 551.91 - 549.41 501 15 1 yes yes
10:55 15400 2.3 e9 30 104522 104526 104526 185 213 551.91 - 549.41 501 15 1 yes yes
11:11 15500 2.6 e9 30 104522 104526 104526 186 214 551.91 - 549.41 501 15 1 yes yes
11:27 15800 2.5 e9 30 104522 104526 104526 187 215 551.91 - 549.41 501 15 1 yes yes
11:41 5200 1.4-2.6 e9 30 104522 104526 104526 188 216 551.91 - 549.41 501 15 1 yes yes
11:56 16500 2.6 e9 30 104522 104526 104526 189 217 551.91 - 549.41 501 15 1 yes yes
12:12 15000 2.9 e9 30 104522 104526 104526 190 218 551.91 - 549.41 501 15 1 yes yes
12:27 15000 2.8 e9 30 104522 104526 104526 191 219 551.91 - 549.41 501 15 1 yes yes
12:44 15800 2.9 e9 30 104522 104526 104526 192 220 551.91 - 549.41 501 15 1 yes yes
13:21 5400 2.3 e9 30 104522 104526 104526 193 221 551.91 - 549.41 501 15 1 yes yes
13:42 4800 2.6 e9 30 104522 104526 104526 194 222 551.91 - 549.41 501 15 1 yes yes
13:59 6200 2.6 e9 30 104522 104526 104526 195 223 551.91 - 549.41 501 15 1 yes yes
  64   Thu Jun 26 22:51:04 2025 Hendrik, FinnRunsNightshift data runs
After the scan at 22:04 teh FCU new was new calibrated. For this MEdusa was stopped and reopened in the laser lab. This stops the Labview server, and as a consequence the the connection to the MBS was lsot. Then, MBS needs to be restarted and the online data is cleared. Such an intervention should avoided as good as possible.
A pratical solution for beamtimes with such long data taking is still pending.
When trying to restart MBS MBS completlz hung up also resl etc did not work. Crate powered down and restarted.

23:10 Quadrupole magnet stopped working, lost beam in ESR. Contacted on-call ESR service

Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position mesytec rate ok comments
0:15 8000 1.5-3.5 e9 30 104522 104526 104526 150 177 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
0:28 20900 1.5-3.5 e9 30 104522 104526 104526 151 178 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
0:59 19000 2.3-2.7 e9 30 104522 104526 104526 152 179 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
1:14 14500 1.5-3.5 e9 30 104522 104526 104526 153 180 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
1:30 19800 1.5-3.5 e9 30 104522 104526 104526 154 181 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
1:45 18000 1.5-3.5 e9 30 104522 104526 104526 155 182 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
2:01 6600 1.5-3.5 e9 30 104522 104526 104526 156 183 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
2:18 14500 1.5-3.5 e9 30 104522 104526 104526 157 184 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
2:36 14700 1.5-3.5 e9 30 104522 104526 104526 158 185 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
2:45 6000 1.5-3.5 e9 30 104522 104526 104526 159 186 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
3:00 5500 1.5-3.5 e9 30 104522 104526 104526 160 187 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
3:17 5200 1.5-3.5 e9 30 104522 104526 104526 161 188 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
3:34 14300 1.5-3.5 e9 30 104522 104526 104526 162 189 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
3:50 17200 1.5-3.5 e9 30 104522 104526 104526 163 190 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
4:07 5000 1.5-3.5 e9 30 104522 104526 104526 164 191 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
4:22 16500 1.5-3.5 e9 30 104522 104526 104526 165 192 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
4:39 14000 1.5-3.5 e9 30 104522 104526 104526 166 193 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
4:55 17000 1.5-3.5 e9 30 104522 104526 104526 167 194 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
5:12 16500 1.5-3.5 e9 30 104522 104526 104526 168 195 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
5:26 14000 1.5-3.5 e9 30 104522 104526 104526 169 196 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
5:43 13100 1.5-3.5 e9 30 104522 104526 104526 170 197 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
5:56 16500 1.5-3.5 e9 30 104522 104526 104526 171 198 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
  63   Thu Jun 26 21:27:34 2025 Carsten, Jan, SimonCalibrationTiming
We checked the timing (before the start of the measurement cycle documented below).
Timing and measurement window are attached.
Attachment 1: Bildschirmfoto_timing_new_2025-06-26_19-00-04.png
Bildschirmfoto_timing_new_2025-06-26_19-00-04.png
  62   Thu Jun 26 19:01:46 2025 Carsten, Jan, SimonRunsLate shift 26.06.

Scan parameters:
scan range551.91 - 549.41
positions501
step width0.005nm
advance after15 rising edges
iterations1
rev. frequency 1.54315e6




Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position mesytec rate ok comments
19:15 23000 1.5-3.5 e9 33 104522 104526 104526 142 170 551.91 - 549.41 501 15 1 yes yes TE slits at -10 and +10, SIS intensity unstable
19:41 19000 3.3e9 30 104522 104526 104526 143 171 551.91 - 549.41 501 15 1 yes yes TE slits at -7 and +7
20:08 17500 3.3e9 25 104522 104526 104526 144 172 551.91 - 549.41 501 15 1 yes yes -
20:24 7000 3.3e9 25 104522 104526 104526 145 173 551.91 - 549.41 501 15 1 yes yes low Part. Det. Int maybe due to wrond position of part. det.
21:19 7000 3.5e9 25 104522 104526 104526 146 174 551.91 - 549.41 501 15 1 yes yes TE slits at -8 and +8
21:40 14000 3.3e9 25 104522 104526 104526 147 175 551.91 - 549.41 501 15 1 yes yes adjusted particle detector position
22:04 19500 3.3e9 40 104522 104526 104526 148 176 551.91 - 549.41 501 15 1 yes yes


After the scan at 22:04 teh FCU new was new calibrated. For this MEdusa was stopped and reopened in the laser lab. This stops the Labview server, and as a consequence the the connection to the MBS was lsot. Then, MBS needs to be restarted and the online data is cleared. Such an intervention should avoided as good as possible.
A pratical solution for beamtimes with such long data taking is still pending.
When trying to restart MBS MBS completlz hung up also resl etc did not work. Crate powered down and restarted.
  61   Thu Jun 26 18:13:17 2025 Jan, CarstenDetectorsPMT voltages & thresholds
current settings of PMT voltages and thresholds at the CAEN CFD:

PMT South   [HV ch2: 2700V]  [CFD ch0: 8]

PMT Middle  [HV ch1: 2850V]  [CFD ch1: 8]

PMT Nord    [HV ch3: 2850V]  [CFD ch2: 9]
  60   Wed Jun 25 05:53:54 2025 RodolfoLaserFCU
Cobra's FCU was recalibrated. Table saved as FCU_547-554_RS_2024-06-25.fcu.
  59   Tue Jun 24 22:24:36 2025 Carsten, Finn, Hiroshi, Esther, RodolfoRunsData taking (night shift 24.06.)

Scan parameters:
scan range551.91 - 549.41
positions501
step width0.005nm
advance after15 rising edges
iterations1
rev. frequency 1.54315e6


Notes:
1. NTCAP was only started after the fourth scan. The file timestamp is '2025-06-25_00-02-08'.
2. Beam was lost at 03:45 and could not be recovered by the operators. On-call service was called but they have to replace a part, current estimate is 2-3 hours.

Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position comments
22:39 13500 2.4e9 60 104510 104514 104514 128 157 551.91 - 549.41 501 15 1 yes 60 injections, cooling time (SC 7) 28s -> 32s
23:00 11500 2.4e9 45 104510 104514 104514 129 158 551.91 - 549.41 501 15 1 yes 45 injections
23:20 10500 2.4e9 45 104510 104514 104514 130 159 551.91 - 549.41 501 15 1 yes
23:44 9100 2.4e9 45 104510 104514 104514 131 160 551.91 - 549.41 501 15 1 yes
00:05 14000 2.4e9 60 104510 104514 104514 132 161 551.91 - 549.41 501 15 1 yes back to 60 injections
00:28 14300 2.4e9 75 104510 104514 104514 133 162 551.91 - 549.41 501 15 1 yes 75 injections, mesytec channel threshold 0-3 set 255
01:26 13200 2.4e9 75 104510 104514 104514 134 163 551.91 - 549.41 501 15 1 yes there was an interruption at the source, took some time to get the beam back
01:48 10500 2.3e9 75 104510 104514 104514 135 164 551.91 - 549.41 501 15 1 yes
02:10 12400 2.3e9 75 104510 104514 104514 136 165 551.91 - 549.41 501 15 1 yes
02:33 9600 2.4e9 75 104510 104514 104514 137 166 551.91 - 549.41 501 15 1 yes
02:55 10000 2.4e9 75 104510 104514 104514 138 167 551.91 - 549.41 501 15 1 yes
03:18 9600 2.4e9 75 104510 104514 104514 139 168 551.91 - 549.41 501 15 1 yes
  58   Tue Jun 24 18:49:18 2025 Carsten, Rima, Nils, SimonRunsSecond attempt (Late shift 24.06.)

Scan parameters:
scan range551.91 - 549.41
positions501
step width0.005nm
advance after15 rising edges
iterations1
rev. frequency 1.54315e6



Time Part. Det. Int SIS-intensity accumulations in ESR cooler-HV PTB K250 cooler-HV PTB red cooler-HV orange LMD-DAQ1 Files LMD-DAQ2 Files scan range(nm) number of positions dwell time (laser shots) n loops checked laser position comments
19:03 14800 2.7e9 60 104510 104514 104514 118 147 551.91 - 549.41 501 15 1 yes TE beamline slits -30 +30
19:22 14900 2.7e9 60 104510 104514 104514 119 148 551.91 - 549.41 501 15 1 yes -
19:40 14500 2.7e9 60 104510 104514 104514 120 149 551.91 - 549.41 501 15 1 yes TE beamline slits -20 +20
19:58 13800 2.0e9 60 104510 104514 104514 121 150 551.91 - 549.41 501 15 1 yes -
20:18 10800 2.1e9 60 104510 104514 104514 122 151 551.91 - 549.41 501 15 1 yes -
20:37 10100 2.1e9 60 104510 104514 104514 123 152 551.91 - 549.41 501 15 1 yes -
20:56 10500 2.1e9 60 104510 104514 104514 124 153 551.91 - 549.41 501 15 1 yes -
21:15 9000 2.2e9 60 104510 104514 104514 125 154 551.91 - 549.41 501 15 1 yes after this we change to 45 injections to give more cave access to HHT
21:37 11500 2.3e9 45 104510 104514 104514 126 155 551.91 - 549.41 501 15 1 yes small pause for HHT
22:13 13400 2.5e9 45 104510 104514 104514 127 156 551.91 - 549.41 501 15 1 yes small pause for HHT, cooling time in SC7 increased from 20s to 28 s
  57   Tue Jun 24 17:39:13 2025 Carsten, Stefan, Simon, Rima, NilsDetectorsPMT behaviour - noise / PMT voltages / CFD Threshholds / CAEN Power supply (broken channel resetted)
PMT North and South have been changed:

CFD CH0: Middle Thr 7 / CAEN HV Ch1: 2750 V
CFD CH1: South Thr 8 / CAEN HV Ch2: 2700 V
CFD CH2: North Thr 8 / CAEN HV CH3: 2800 V

MESY CFD Ch4: Thr.17
MESY CFD Ch5: Thr.16
MESY CFD Ch6: Thr.20


Quote:
In position North there is still the "old" 9423B PMT that draws quite some current.
On this detector threre is also some quite substantial noise. Very likely the base is not ok any more. Noise was much lesss for the other two PMTs.
Since position NORTH is the position with the largest sold angle, if there is another break from the accelerator we should exchange it against SOUTH.
It was also difficult to ramp up PMT north ; and I thought that againa channel broke (showing UnV not OVC (Overcurrent)). However, the PS is resetted if
you switch of the whole crate (aka switch the PS off). Before doing so, please ramp down the other channels slowly as intended.


Please leave the PMTs (besides you go in to exhchange the PMTs).
If you ramp pt PMT North (or the same detector at a different position), start with 2400 V and then slowly increase by steps of 50V.

Checked theresholds (but during injections, so in presence of electronic noise from injection). A further adjusted might be done later when we have measurement conditions.
(Or if we have time to exchange the PMTs).


Presently we have the following settings for CAEN:


CH1: Middle 2750 V, Thr 9
CH2: South 2700 V, Thr 7
CH3: North 2800 V, Thr 9
  56   Tue Jun 24 15:44:06 2025 KonstantinDAQPhase shift in DAQ1
In the SetParameters.C file is a parameter called fPar->piPhaseOffset. It was shifted from 100 to 50 in order to see ion bunches in the pmt signal and laser pulses in the photodiode signal during the same revolution in the TDC spectrum. Note that this parameter must be taken 
into account when setting the window conditions of the arrival time in the SetConditions.C file. 
  55   Tue Jun 24 12:25:34 2025 CarstenDetectorsPMT behaviour - noise / PMT voltages / CFD Threshholds / CAEN Power supply (broken channel resetted)
In position North there is still the "old" 9423B PMT that draws quite some current.
On this detector threre is also some quite substantial noise. Very likely the base is not ok any more. Noise was much lesss for the other two PMTs.
Since position NORTH is the position with the largest sold angle, if there is another break from the accelerator we should exchange it against SOUTH.
It was also difficult to ramp up PMT north ; and I thought that againa channel broke (showing UnV not OVC (Overcurrent)). However, the PS is resetted if
you switch of the whole crate (aka switch the PS off). Before doing so, please ramp down the other channels slowly as intended.


Please leave the PMTs (besides you go in to exhchange the PMTs).
If you ramp pt PMT North (or the same detector at a different position), start with 2400 V and then slowly increase by steps of 50V.

Checked theresholds (but during injections, so in presence of electronic noise from injection). A further adjusted might be done later when we have measurement conditions.
(Or if we have time to exchange the PMTs).


Presently we have the following settings for CAEN:


CH1: Middle 2750 V, Thr 9
CH2: South 2700 V, Thr 7
CH3: North 2800 V, Thr 9
  54   Mon Jun 23 18:36:39 2025 Wilfried, SimonDetectorsPMT test with LED
We tested the PMTs again, this time with an UV LED that is mounted at a window close to the XUV detector.
PMT south showed a very clear increase in count rate from about 1 to 50 Hz.
PMT mid also showed a small increase by a few Hz.
For PMT north there was no great change between LED off and on, but we think that the count rate also very slightly increased. Note, that PMT north is also the furthest away from the LED.

Also we saw a difference between single- and multi-photon events at PMT south.
  53   Mon Jun 23 10:59:36 2025 Julian, Lukas, Zsolt, Nadine, KonstantinRunsScan routine
-Start new injection
->wait for 60 injections to be complete
->note down SIS intensity (at extraction)
->observe Schottky to ensure proper bunching
->check laser position (should be well-centered)
-open file, start Go4
->do '@openfile' in both mbs windows
->start acquisition (green arrow) in both Go4 instances (check indicator 'Current Ev/s' at the bottom, should be green, not red)
->start laser scan
->reset Ch3 of the particle detector (in the electronics hut)
->check laser position (disappears at start of scan then drifts through the image from the left)
-when laser scan is finished:
->stop Go4 acquisition (big red 'STOP' button in the top row)
->do '@closefile' in both mbs windows
->check counts on particle detector
-update elog
-repeat
  51   Mon Jun 23 10:52:34 2025 Julian, Lukas, Zsolt, Nadine, KonstantinLaserFrequency conversion unit
We exchanged the old BBO of the Cobra's FCU with a new one. The output power of the Cobra was around 120mJ. In the end, we achieved a UV power of about 21mJ. In addition, we optimized the fiber-coupling to the wavemeter. 