  104  
 | 
Mon Mar 30 23:30:35 2020 | 
Jan | Analysis | run251 - Si-pad performance & status | Attached are plots for Si-pad 2 with hits 
from ionization of 206Pb81+ at the target.
 
The plots are representative for all Si-pads, | 
 7x   | 
| 
  105  
 | 
Tue Mar 31 00:47:18 2020 | 
Yuri | Runs | S2 slits 0/+35 mm, target bump +13 mm | Run start: 0276.lmd | 
   | 
| 
  106  
 | 
Tue Mar 31 15:30:43 2020 | 
ruijiu | Analysis | The beam position  on DSSD with different conditions on on the dEE spectrum | I analyzed the first measurement with 206Pb81+ 
beam, run 250-267.  | 
 6x   | 
| 
  107  
 | 
Tue Mar 31 20:32:05 2020 | 
Ragan | General | 203Tl80+  200Hg79+ 205Tl81+ | Below in the schottky spectrum, on left is 
203Tl80+ contamination, in middel is 200Hg79+ 
contamination and on right most is 205Tl81+.
 | 
    | 
| 
  108  
 | 
Tue Mar 31 20:50:05 2020 | 
Ragan | General | 200Hg79+ 205Tl81+ | 203Tl80+ impurity is removed by moving scrapper 
inside ESR.
 
Only 220Hg79+ is left now | 
    | 
| 
  109  
 | 
Tue Mar 31 21:07:05 2020 | 
Ragan | General | Separation of 203Tl80+ and 200Hg79+ using scrapper in ESR | It can be seen in the video how 203Tl80+ (on 
extreme left) and then 200Hg79+ (in middle 
originally) is separted from 205Tl81+ by | 
    | 
| 
  110  
 | 
Tue Mar 31 23:31:41 2020 | 
Shahab | Runs | alpha_p calibration | Vc = 212849.9349
 
Ic = 0.2
 
 | 
    | 
| 
  111  
 | 
Wed Apr  1 01:02:24 2020 | 
ruijiu | Detectors | the detector cable is disconnected. |   | 
   | 
| 
  112  
 | 
Wed Apr  1 01:05:36 2020 | 
ruijiu | Detectors | detector position fixed at 60 mm | The detector cable was disconnected . We entered 
and reconnected the cable. | 
    | 
| 
  113  
 | 
Thu Apr  2 02:36:48 2020 | 
Ragan | General | Stochastic cooling and orbit problem | On 1 April by 5 pm, we could stop the stochastic 
cooling after the stacking process and also 
change the orbit of the Tl beam to centre. | 
   | 
| 
  114  
 | 
Thu Apr  2 02:38:32 2020 | 
Ragan, Yuri, Sergey, Esther, Oliver | Runs | First measurement with zero storage time | beam: 205Tl81+ (with no scraping)
 
energy: 400 MeV/u
 
storage time: zero
 | 
   | 
| 
  115  
 | 
Thu Apr  2 02:46:57 2020 | 
Ragan, Yuri, Sergey, Esther, Oliver | Runs | Measurement with 2 hrs storage time | 
 
 
 | 
    | 
| 
  116  
 | 
Thu Apr  2 05:00:44 2020 | 
Ragan, Esther, Oliver | Runs | Second measurement with 2 hrs storage time | Electron cooler was off here. Thus, this measurement 
is not what we needed.
 
(in the picture below, it can be seen that | 
    | 
| 
  117  
 | 
Thu Apr  2 06:25:13 2020 | 
Ragan | Runs | Template | beam: 205Tl81+ (no scraping)
 
energy: 400 MeV/u
 
storage time: ___ hrs
 | 
   | 
| 
  118  
 | 
Thu Apr  2 07:01:32 2020 | 
Ragan, Esther, Oliver | Runs | Measurement with 4 hrs storage time | beam: 205Tl81+ (no scraping)
 
energy: 400 MeV/u
 
storage time: 4 hrs
 | 
   | 
| 
  119  
 | 
Thu Apr  2 09:21:19 2020 | 
Ruijiu | Runs | 2nd measurement with 2 hrs storage time (repeat) | Because the electron cooler was not switched 
on during beam accumulation in the previous 
measurement, we repeat this measurement again.
 | 
    | 
| 
  120  
 | 
Thu Apr  2 12:52:25 2020 | 
ruijiu | General | setup FRS with 2 g/cm2 degrader. | Yuri sets up FRS with 2 g/cm2 degrader (previous 
one is 1 g/cm2). The ESR is not changed. 
The contamination should be less now. | 
   | 
| 
  121  
 | 
Thu Apr  2 15:24:15 2020 | 
Ragan | General | How to know whether electron cooling is working | For Alle and Kuehler the bottom left status 
should look like as shown in pictures below. | 
     | 
| 
  122  
 | 
Thu Apr  2 21:03:40 2020 | 
Ragan, Yuri, Sergey, Nikos | Runs | Zero hour measurement (S2:-10/35 mm) | beam: 205Tl81+ (no scraping, Al ~1g/cm2)
 
energy: 400 MeV/u
 
storage time: zero hrs
 | 
   | 
| 
  123  
 | 
Thu Apr  2 21:10:57 2020 | 
Ragan, Yuri, Sergey, Nikos | Runs | One hour measurement (S2:-10/35 mm) | beam: 205Tl81+ (no scraping, Al ~1g/cm2)
 
energy: 400 MeV/u
 
storage time: 1 hrs
 | 
   |