164
|
Mon Apr 6 05:43:50 2020 |
Ragan, Laszlo, Nikos | Runs | One and a half hour measurement (S2: 0/35 mm and S6: -20/7 mm) | beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 1.5 hr
|
   |
165
|
Mon Apr 6 08:37:02 2020 |
Ragan, Shahab, Pierre-Michel | Runs | 10 hour measurement (S2: 0/35 mm and S6: -20/7 mm) | beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 10 hr
|
8x |
166
|
Mon Apr 6 09:34:58 2020 |
Shahab | Runs | Pictures from one and a half hour measurement | cheers! |
|
167
|
Mon Apr 6 14:17:54 2020 |
Yuri, Shahab | Runs | FRS valves | We saw reduction in ESR beam life. It turned
out that FRS has opened valves and venting
caused us reduction of the quality of vacuum |
|
168
|
Mon Apr 6 14:57:04 2020 |
Shahab | Runs | cooler down | cooler component GECEBG2T again had to be
reset. |
|
169
|
Mon Apr 6 20:03:50 2020 |
Ragan | General | Experiment finished )) | E121 experiment is finished with the last
10 hours measurement at 19:47 ))
Many thanks to everyone for there significant |
|
170
|
Thu Apr 9 11:16:35 2020 |
Ragan | General | Measurements done in the experiment | |
  |
171
|
Thu Apr 9 11:47:28 2020 |
ruijiu | | backup data | 2020.4.8 12:00Started copying
data。
2020.4.9 11:52 Copied 6.3TB
|
|
172
|
Fri Apr 17 18:27:34 2020 |
ruijiu | Analysis | backup data | 1.connect USB harddisk to computer lxg1254
and copy data to sever.
|
|
173
|
Mon Apr 20 11:17:18 2020 |
Ragan | General | Logbook | |
  |
174
|
Wed Aug 5 17:19:16 2020 |
Rui-Jiu Chen | Analysis | Data structure | |
|
175
|
Thu Oct 1 22:20:03 2020 |
Jan | DAQ | final unpacker config | We identified an issue with randomly missing
adc channels in all lmd-files before run
0273.
|
 |
176
|
Mon Nov 2 16:45:55 2020 |
Jan | DAQ | f_user & mbslog | Attached is the f_user.c and the mbslog.l
files.
The readout function is for the following |
 |
177
|
Thu Nov 5 15:13:43 2020 |
Jan | Analysis | root script example | Attached is an example root script/macro that
shows how to use scripts for analysis.
|
  |
178
|
Thu Nov 19 09:14:40 2020 |
Jan | Detectors | remote MSCF settings for CsISiPHOS | Attached is a list of all set values for the
5 MSCF shaper modules.
This was done prior to run0251, which served |
 |
180
|
Tue Dec 8 15:47:07 2020 |
Jan | Detectors | manual preamp & shaper settings for CsISiPhos | attached is a document showing fotos of all
involved amplifiers in the chain to document
the manual settings active during the experiment.
|
|
181
|
Tue Dec 15 09:25:41 2020 |
Jan | DAQ | SiCsIPhos signal/amplitude reconstruction | |
|
182
|
Mon Mar 29 16:31:09 2021 |
Pierre-Michel | DAQ | cross section | (1.393*^-8 + 3.18*^-13 + 4.707*^-8)/4.707*^-8
= 1.29595 |
|
183
|
Sun May 30 12:09:00 2021 |
Ragan | General | NTCAP | Attached is the info given by Carsten.
The instructions to operate NTCAP are given
on https://wiki.gsi.de/ESR_EXP/ManualOfNTCAP |
|
184
|
Wed Aug 25 15:13:41 2021 |
Jan | DAQ | SC13 clock frequency | The frequency of the clock used as reference
in scaler channel 13 has been measured precisely.
In contrast to what was expected (1.5MHz |
|