HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  proton-capture on 118Te, Page 14 of 29  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Authordown Category Subject Year Text Attachments
  388   Sat May 22 16:29:07 2021 Laszlo et al.Generalcoolers are back2021we can measure again.

(please write a detailed description if needed)
  
  3   Wed Feb 6 10:04:23 2019 Laszlo VargaSimulationsBackground subtraction for 124Xe, 109In, 73As made by MOCADI General remarks to the MOCADI simulations:


scraper size vertically > (p,g) spot at the
scraping position --> (p,g) can be separated
 template.pdf 
  4   Wed Feb 6 10:16:09 2019 Laszlo VargaGeneralStudy on scraping A publication on scraping systems suggested
by Siegbert. 
In the study they have used cylindrical "high-quality"
 1-s2.0-0168583X88900122-main.pdf 
  14   Tue Jun 25 21:19:50 2019 LaszloSimulationsMOCADI input parameters initial BEAM input parameters for MOCADI are
based on:
- https://web-docs.gsi.de/~weick/mocadi/download/esr-exl-test.in
 template.pdfsteck2004.pdf 
  18   Tue Jul 23 10:46:29 2019 LaszloAnalysis124Xe pg peak fit using mixed cascade simulation This entry is the continuation of the cascade
effects on the pg peak shape entry:
 7x 
  Draft   Fri Aug 9 13:14:09 2019 Laszlo pn channel simulations for 111Sn(p,g)112Sb experiment The p,n channel opening for the 111Sn+p reaction
is at 5.8895 MeV/u beam energy. Therefore,
when choosing as 6MeV/u, 7MeV/u, 8MeV/u beam
  
  20   Fri Aug 9 13:43:15 2019 LaszloSimulationspn channel simulations for 111Sn(p,g)112Sb experiment The p,n channel opening for 111Sn beam is
at 5.8895 MeV/u beam energy. Therefore, when
choosing 6MeV/u, 7MeV/u,
 12x 
  22   Wed Sep 25 13:03:46 2019 LaszloAnalysissimulations on 118Te+p I have made some simulations at 8AMeV, 7AMeV
and 4AMeV energies for the main 118Te + p
reaction channels. For the
 11x 
  23   Wed Sep 25 13:58:24 2019 LaszloGeneralGamow window energies for 118Te(p,g) # Z   A   Iso Re Rc   T9 upper width mxpos
 shift
 52 118 te118 pg 20  0.5  1.39  0.58  1.06
 PhysRevC.81.045807.pdf 
  29   Fri Nov 15 10:46:12 2019 LaszloDetectorsDetector movement from HKR To move the detector remotely from the HKR:
-go to a desktop of a HKR computer
-right click: "App Launcher PRO"
 IMG_20191114_135600.jpg 
  31   Thu Jan 23 16:35:47 2020 LaszloDAQcable documentation    cable_documentation_e127.pdfcable_documentation_e127.ods 
  34   Fri Feb 21 09:39:40 2020 LaszloDAQcable documentation    cable_documentation_e127.pdfcable_documentation_e127.ods 
  35   Fri Feb 21 11:29:02 2020 LaszloGeneralShift plan https://docs.google.com/spreadsheets/d/14m8WcCq1erx6HqWJRK7TLbCx121IkjqGa5l-frf4YjI/edit#gid=0   
  40   Wed Mar 11 14:33:44 2020 LaszloGeneralbeam time manual Here you can find the digital version of the
E127 beam time manual.
 E127_experimental_manual.pdfmanual.odt 
  49   Sun Mar 15 17:14:08 2020 LaszloCalibrationrun036 - Xray90 calib Am241, distance 200! Detector: 90
Source: Am241 
Distance: 200mm
  
  50   Sun Mar 15 17:33:17 2020 LaszloCalibrationrun037 - Xray90 calib Am241 Detector: 90
Source: Am241 
Distance: 167.5mm
 run037_241Am_145.png 
  51   Sun Mar 15 17:50:42 2020 LaszloCalibrationrun038 - Xray90 calib Ba133, high rate Detector: 90
Source: Ba133 - high rate
Distance: 167.5mm
 run038_133Ba_high_145.png 
  52   Sun Mar 15 18:09:19 2020 LaszloCalibrationrun039 - Xray90 calib Ba133 Detector: 90
Source: Ba133
Distance: 167.5mm
  
  53   Sun Mar 15 18:53:42 2020 LaszloCalibrationrun040 - Xray145 calib Am241 Detector: 145
Source: Am241
Distance: 305mm
 run040_241Am_90.png 
  54   Sun Mar 15 19:22:58 2020 LaszloCalibrationrun041 - Xray145 calib Ba133 - high rate Detector: 145
Source: Ba133
Distance: 305mm
 run041_133Ba_high_90.png 
ELOG V3.1.5-fc6679b