HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
proton-capture on 118Te, Page 15 of 29
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
General
Collaboration
Runs
Detectors
Simulations
Accelerator
572 Entries
Goto page
Previous
1
,
2
,
3
...
14
, 15,
16
...
27
,
28
,
29
Next
ID
Date
Author
Category
Subject
Year
Text
87
Fri Mar 20 19:37:43 2020
Jan
Calibration
Xray energies - rough 1. calibration
-- E calibration seems to have changed! ---
This calibration is based on the source data
270
Sun Apr 5 20:34:42 2020
Laszlo
Calibration
Xray energies - 1. calibration
30angle: E[keV] = 0.0158507 *ch-2.07456
90angle: E[keV] = 0.01950*ch-2.76
145angle: E[keV] = 0.017988 *ch-1.809
8x
397
Sat May 22 21:33:22 2021
Laszlo
Detectors
Xray detectors are filled at 90 and 35
2021
92
Sat Mar 21 01:25:07 2020
Laszlo
General
Vacuum while moving in the detector for fragment measurement
Stayed below E-10
Start:2.42E-11
Top after moving: 4.144E-11
91
Fri Mar 20 23:43:26 2020
Laszlo
General
Vacuum while moving in the detector at yesterday evening
Vacuum before DSSSD movement: 1.5844E-11
Top value after movement: 3.64378E-11
183
Sun Mar 22 12:01:44 2020
Esther, Ragan
General
Vacuum problem with SIS
There is some problem with the vacuum in SIS
and thus data recording is stopped.
359
Thu May 20 18:13:55 2021
Laszlo
General
Vacuum change while Si movement
2021
The vacuum remained in the E-10 range after
moving the dsssd. The oscillation in the
vacuum.values are due to the
25
Wed Oct 23 14:51:43 2019
Jan, Laszlo
DAQ
VME modules & main.cfg
Here is the current list of VME modules in
our DRASI daq including HW addresses:
574
Thu Jun 24 09:43:01 2021
Jan Glorius
DAQ
Unpacker
2021
The unpacker used for the production runs
of E127b is located at
/u/litv-exp/unpacker/unpackexps/e127_TO_2021_with_ECL
292
Wed Apr 28 09:12:47 2021
Jan, Yuri
Detectors
UI-diagram
2021
The UI-curve of the detector
U I
10 0.11
448
Tue May 25 15:56:48 2021
Robert/Shahab
Accelerator
Trafo
2021
Trafo was set to 0
358
Thu May 20 18:11:24 2021
Laszlo
General
Touching the beam with Dsssd - current change
2021
16
Mon Jul 8 14:57:07 2019
Yuanming Xing
Detectors
The measurement of the tilting angle
As shown in the figure, the detector is tilted
by a certain angle which is about 45 degree.
284
Fri Oct 23 12:58:12 2020
Jan
Detectors
Test of 2nd DSSSD (gen2)
2021
This is the documentation of the source tests
with the 2nd micron DSSSD of 2nd generation
(label 3288-17, thickness 529um)
285
Fri Nov 20 15:53:37 2020
Jan
Analysis
Test of 2nd DSSSD (gen2)
2021
Here is the analysis of the test runs with
the 2nd DSSD (gen2) using the quick_si_plots.c
script attached.
571
Wed Jun 2 09:14:04 2021
Jan
General
Telegram Chat Export
2021
Attached is the exported Telegram chat.
There is the simple PDF and the zip-file
containing the chat in json-format as well
159
Sun Mar 22 01:36:14 2020
Pierre-Michel
Analysis
Target overlap
Here are the data file for the rates of the
recoil detector for different values of the
target bump. The average rate over background
10x
89
Fri Mar 20 22:51:36 2020
Laszlo
General
Target on signal change
From the previous settings:
JetOn
mashine number 11
115
Sat Mar 21 10:20:27 2020
Ragan, Alex
General
Target LN2
The LN2 Dewar on the ESR roof has been refilled.
67
Fri Mar 20 01:11:58 2020
Laszlo
General
Target - beam jntersection
We have managed to find the target position
with the beam by looking at the xray spectra.
The trick was that at 10mev we
Goto page
Previous
1
,
2
,
3
...
14
, 15,
16
...
27
,
28
,
29
Next
ELOG V3.1.5-fc6679b