HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028
  proton-capture on 118Te, Page 15 of 29  Not logged in ELOG logo
Entry  Sun May 30 14:40:55 2021, Jan, Sophia, Detectors, real detector assignment, 2021 
************************************
GEM1800 @ 90deg (xray1) 
GLP2000 @ 35deg (xray2)
Entry  Sun May 30 14:48:09 2021, Jan, Sophia, Calibration, run0215 - crap, 2021 
 
Entry  Mon May 31 10:08:42 2021, Jan, Sophia, Runs, E127b runsheet, 2021 e127b_runsheet.ods
 
Entry  Mon May 31 14:38:33 2021, Sophia, Calibration, Runlist for X-ray detector calibrations after the experiment, 2021 Kopie_von_E127_Runlist-calibrations-4-3-1.xlsx
The by Jacobus Swartz created table in entry 335 extended by the calibration after the experiment.
Entry  Wed Jun 2 09:14:04 2021, Jan, General, Telegram Chat Export, 2021 E127_TelegramChat.pdfE127_TelegramChat_json.zip
Attached is the exported Telegram chat.
There is the simple PDF and the zip-file containing the chat in json-format as well as all media files.
Entry  Tue Jun 8 15:06:17 2021, Shahab, Analysis, Beam lifetime, 2021 pgamma_lifetime.001.pngpgamma_lifetime.002.png
measured beam lifetime after the second deceleration using parallel plate Schottky detector and the RSA5103 spectrum analyser. Analysis code can be found
here:
Entry  Wed Jun 23 12:29:35 2021, Jan, Sophia, Calibration, Efficiency of the x-ray Detectors , 2021 Effizienz_x_ray_GEM1800_90.pngEffizienz_x_ray_GEM3000_145.pngEffizienz_x_ray_GLP_35_ohne33keV.png
For the x-ray detectors, efficiencies have been measured, before and after the experiment was performed. 
The preliminary results of the determined efficiencies can be seen in the attached plots 
Entry  Thu Jun 24 09:43:01 2021, Jan Glorius, DAQ, Unpacker, 2021 
The unpacker used for the production runs of E127b is located at 
/u/litv-exp/unpacker/unpackexps/e127_TO_2021_with_ECL
Entry  Thu Jul 8 13:39:34 2021, Jan, Calibration, Electron cooler parameters, 2021 
Below are the results from the e-cooler voltage offset measurments done by Regina Hess et al. using the voltage divider (VD).

--7 MeV-- 
Entry  Thu Jul 8 14:07:19 2021, Jan, Calibration, beam energies, 2021 CodeCogsEqn.pngCodeCogsEqn(1).png
Table of ion energies calculated from cooler parameters

[TABLE border="1"]
Entry  Wed Jul 14 14:46:05 2021, Jan, Sophia, Detectors, collimator geometry, 2021 10x
We have measured the collimator geometry. The annotations of the variables can be found in the attached sketch  

[TABLE border="1"]
Entry  Wed Oct 13 15:09:04 2021, Jan, Collaboration, K-REC cross sections A. Surzhykov, 2021 DCS_Z_52_Tp_7.049MeV_NEW.datDCS_Z_54_Tp_7.049MeV_NEW.datDCS_Z_52_Tp_6.042MeV_NEW.dat
Attached are the theory K-REC cross sections as calculated by Andrey Surzhykov (August 2021).

They are done for 118Te52+ on H2 at 7.049 and 6.042 MeV/u as well as for 124Xe54+ on H2 at 7.049 MeV/u.
Entry  Wed Oct 13 15:15:53 2021, Jan, DAQ, root-file header for analysis, 2021 e127b.h
Attached is the header file needed for root analysis.
Entry  Mon Mar 23 08:04:07 2020, Shahab, Laszlo,Yury, Runs, run entry - run094, 2020 2020-03-23_08-13-00-443.png
open file : run094

beam: 124Xe54+
Entry  Fri Jun 5 14:06:15 2020, Laszlo, Detectors, DSSSD and SCRAPER position estimate for Xe and Te experiments, 2020 SP54120060514100.pdfDSSSD_new1.pdfIMG_20200321_025644.jpg
We don't know the exact absolute positions of the detector (+scraper) and the beam. However, what we have to know is only these two relative positions respect
to each other. To get this distance I use two methods:
1, combining the infos from the set position during the beamtime + the measured pg peak position on the detector. The pg peak position is defined only
Entry  Thu Sep 13 11:42:33 2018, Jan Glorius, Collaboration, Proposal,  E127_Reifarth_pg.pdfE127_Approval.pdf
Attached is the beam time proposal submitted and accepted by the G-PAC in 2017.    
Entry  Thu Jan 17 08:45:43 2019, Jan, Detectors, Micron W1 DSSSD - technical information,  6x
Attached are the spec sheets and design drawings of the new DSSSDs from Micron.
Additionally, the 3D model made by Laszlo is also attached as stp and dwg.
Entry  Wed Feb 6 10:04:23 2019, Laszlo Varga, Simulations, Background subtraction for 124Xe, 109In, 73As made by MOCADI,  template.pdf
General remarks to the MOCADI simulations:

 scraper size vertically > (p,g) spot at the scraping position --> (p,g) can be separated
by truncating the
backscattered Rutherford events in the energy.

 replacing the atomic masses to nuclear masses does not change significantly the absolute positions of the
(p,g) and the Rutherford.
Entry  Wed Feb 6 10:16:09 2019, Laszlo Varga, General, Study on scraping,  1-s2.0-0168583X88900122-main.pdf
A publication on scraping systems suggested by Siegbert. 
In the study they have used cylindrical "high-quality" slits. "High-quality" stands for well polished surface
with surface roughness <50nm. The material of the slit is Tungsten Carbide. 
Entry  Fri Apr 5 05:46:20 2019, Jan, DAQ, running DRASI for (p,g),  
We now have a drasi DAQ running for our (p,g) experiments.
The RIO we have it installed right now is: r4l-58
It shall be used with the user <litv-exp>
ELOG V3.1.5-fc6679b