HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  proton-capture on 118Te, Page 22 of 29  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Authordown Category Subject Year Text Attachments
  340   Fri May 14 11:17:48 2021 Jan GloriusCalibrationrun0043 - Xray145 calib 210Pb d=305mm2021Efficiency calibration in the lab

************************************
  
  341   Fri May 14 13:58:52 2021 Jan GloriusCalibrationrun0044 - Xray145 calib 210Pb d=305mm2021Efficiency calibration in the lab

************************************
  
  342   Sat May 15 20:21:59 2021 Jan GloriusCalibrationrun0045 - Si pulser run2021Detector: DSSD
Source: CAEN Detector Emulator
  
  343   Sun May 16 11:25:25 2021 Jan GloriusCalibrationrun0046 - Xray E-calib 241Am all dets2021Detectors: Xray1 (GEM1800), Xray2 (GLP), Xray3
(GEM3000)
Sources: different Am241 at each detector
  
  344   Sun May 16 11:54:12 2021 Jan GloriusCalibrationXray performance in lab2021These are the current Xray detector performances
in the lab using data from run0046
  
  345   Sun May 16 12:55:48 2021 Jan GloriusDAQevent server lxg1299:60032021new event server is set up at lxg1299 on port
6003
It runs as:
  
  347   Tue May 18 01:03:59 2021 Jan GloriusCalibrationrun0048 - calib all Xray det.2021Efficiency calibration in ESR

************************************
  
  348   Tue May 18 01:21:27 2021 Jan GloriusCalibrationrun0047 - crap2021    
  349   Tue May 18 11:22:57 2021 Jan GloriusCalibrationrun0049 - calib all Xray det.2021Efficiency calibration in ESR

************************************
  
  351   Wed May 19 13:47:26 2021 Jan GloriusGeneralGasTarget Operation2021We have two tasks to take over for the target
operation:
 IMG_20210519_133923186_HDR.jpgIMG_20210519_133629322_HDR.jpg 
  563   Sun May 30 10:24:20 2021 Jan GloriusCalibrationrun0212 - X-calib. 90-pb 145-am2021Efficiency calibration in ESR after experiment

************************************
  
  564   Sun May 30 11:32:06 2021 Jan GloriusCalibrationrun0213 - X-calib. 90-am 145-pb 35-ba2021Efficiency calibration in ESR after experiment

************************************
  
  565   Sun May 30 13:23:26 2021 Jan GloriusCalibrationrun0214 - X-calib. 90-ba 145-ba 35-am2021Efficiency calibration in ESR after experiment

************************************
  
  566   Sun May 30 14:38:09 2021 Jan GloriusCalibrationrun0216 - X-calib. 90-ba 35-pb2021Efficiency calibration in ESR after experiment

************************************
  
  574   Thu Jun 24 09:43:01 2021 Jan GloriusDAQUnpacker2021The unpacker used for the production runs
of E127b is located at 
/u/litv-exp/unpacker/unpackexps/e127_TO_2021_with_ECL
  
  2   Thu Jan 17 08:45:43 2019 JanDetectorsMicron W1 DSSSD - technical information Attached are the spec sheets and design drawings
of the new DSSSDs from Micron.
Additionally, the 3D model made by Laszlo
 6x 
  5   Fri Apr 5 05:46:20 2019 JanDAQrunning DRASI for (p,g) We now have a drasi DAQ running for our (p,g)
experiments.
The RIO we have it installed right now is:
  
  6   Fri Apr 5 06:05:55 2019 JanDAQmaking changes to the DAQ  If you need to add or change a module of the
VME crate you need to follow this proceedure:
  
  7   Wed Jun 5 11:29:13 2019 JanDetectorsposition/channel calib. This is the first position calibration done
with the detector installed in the holder.
The goal is to assign rough positions (top/bottom/left/right)
  
  8   Fri Jun 7 10:18:23 2019 JanRunsprerun001 - MixedAlpha save point: lxg1275:/datalocal1/e127/predata/prerun001-root

~2h run
 alpha_centered.jpg 
ELOG V3.1.5-fc6679b