62
|
Sat Apr 2 01:27:25 2022 |
Jan Glorius | Runs | test runs 02.04.2022 | Beam settings:
primary beam
copper stripper
|
|
78
|
Sun Apr 3 12:31:10 2022 |
Rui-Jiu Chen, Yuri, Carsten, Ragan | Runs | Measurement of beam with different circles | Parameters of NTCAP:
1. IQ rate 20 MSamples/s
|
6x |
86
|
Mon Apr 4 09:10:44 2022 |
Ragan, Yuri, Rui-Jiu | Runs | Measurement | NTCAP is taking data with the beam with a
stop at manipulation 5 (taking all the fragments).
|
|
104
|
Tue Apr 5 23:55:11 2022 |
Carsten | Runs | Long time measurment with NTCAP | Settings:
Center: 2242.5MHz
RefLevel: -25dB
|
|
110
|
Wed Apr 6 14:52:29 2022 |
Rodolfo | Runs | Scraping the ion beam | We are T-scraping the ion beam. |
|
121
|
Thu Apr 7 02:32:29 2022 |
all on shift | Runs | First Scans 322-320nm | Laser scanning from 322-320 steps 0.01nm/s
DAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
|
|
151
|
Fri Apr 8 06:53:29 2022 |
Ragan | Runs | NTCAP data taking | NTCAP is taking data since 07.04.2022 23:53:47
Carrier Frequency: 242.2 M
|
|
155
|
Fri Apr 8 09:32:32 2022 |
Ragan | Runs | NTCAP stopped | Since there is no beam, NTCAP is stopped.
Carrier Frequency: 242.2 M
|
|
157
|
Fri Apr 8 09:39:04 2022 |
Ragan | Runs | NTCAP started | Carrier Frequency: 242.2 M
IQ Rate (S/s): 10 M
Reference level (dBm): -30
|
|
158
|
Fri Apr 8 10:44:55 2022 |
Ragan, Yuri, Danyal, Sergey | Runs | NTCAP stopped | NTCAP is stopped. Sergey will now set an ion
bunch instead of two in the ESR.
|
|
161
|
Fri Apr 8 12:04:13 2022 |
Ragan | Runs | NTCAP started | NTCAP is started for the data taking.
Carrier Frequency: 242.02 M
|
|
166
|
Fri Apr 8 15:39:36 2022 |
all | Runs | first data after timing set up | started taking data again
started at 15:40
|
|
181
|
Sat Apr 9 06:25:22 2022 |
Max, Kristian | Runs | morning shift runs | DAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
|
|
183
|
Sat Apr 9 13:45:42 2022 |
Max, Kristian | Runs | first scans with LV problem solved! | This is the first time with LV buffer problem
solved (see Elog ID: 184). Before the PMT
signals were out of sync with the wavelength |
|
185
|
Sat Apr 9 15:47:21 2022 |
Carsten, Rodolfo, Sarper, Patrick | Runs | Afternoon and night shift runs | After the morning shift, we got new increment
(nm) for the laser scanning. We are now scanning
2 nm of wavelength range in 5 big steps (5 |
|
195
|
Sun Apr 10 06:39:16 2022 |
Kristian, Marek, Max | Runs | runs morning shift 10.04. | These are the measurement runs of the morning
shift (10.04.).
|
|
200
|
Sun Apr 10 15:16:19 2022 |
Carsten, Rodolfo, Sarper | Runs | Runs afternoon shifts 10.04 | These are the measurement runs of the afternoon
shift (10.04.).
|
|
203
|
Sun Apr 10 22:47:05 2022 |
Patrick, Volker, Prannay, Danyal, Alexandre, Sebastian, Kristian | Runs | Runs night shift 10.04 + morning shift 11.04 | These are the measurement runs of the night
shift (10/11.04.).
|
|
210
|
Mon Apr 11 14:45:11 2022 |
Paul, Konstantin, Sarper, David | Runs | Afternoon shift runs 11.04 | We continue scan the new wavelength scan range
is 322.41 - 322.00 nm
|
|
215
|
Tue Apr 12 04:43:29 2022 |
Alexandre, Kristian, Sebastian | Runs | 322.01 - 321.60 nm | We scan the wavelength scan range is 322.01
- 321.60 nm
|
|