| ID | Date | Author | Category | Subject | Text |  | 
| 198 | Sun Apr 10 13:17:53 2022 | Kristian, Max | DAQ | Wavemeter readout | We changed the Labview code in order to reduce the amount of data that was overfilling the
 WM data queue. We removed the temperature
 |  | 
| 197 | Sun Apr 10 11:11:18 2022 | Kristian, Max | Laser | additional WM readout | since the WM readout still does not work reliably, I started a python script at atppc023 that
 saves timestamp and wavemeter frequency.
 |  | 
| 196 | Sun Apr 10 08:53:26 2022 | Kristian, Max | Laser | Timing verified | timing is still good. 
 we checked the relative timing between laser
 |  | 
| 195 | Sun Apr 10 06:39:16 2022 | Kristian, Marek, Max | Runs | runs morning shift 10.04. | These are the measurement runs of the morning shift (10.04.).
 
 |  | 
| 194 | Sun Apr 10 06:34:49 2022 | Kristian, Max | DAQ | Wavemeter Readout | Problem solved. Ignore this entry 
 
 |  | 
| 193 | Sun Apr 10 04:37:29 2022 | Patrick | DAQ | Next wavelength range | Measurements with the next wavelength scan range should be started roughly around 12:00
 noon. The plan is to go to lower wavelengths
 |   | 
| 192 | Sun Apr 10 04:07:53 2022 | Patrick | DAQ | go4 shows wrong frequencies and wavelengths | [B]Update (ID:194):[/B] In labview "Stop All", close labview, stop python script (ID:197),
 close wavemeter. Then restart wavemeter,
 |     | 
| 191 | Sun Apr 10 03:56:56 2022 | V. Hannen | Detectors | Low rate in PMT South | PMT south shows a much lower count rate than observed in elog entry 170.
 
 |   | 
| 190 | Sun Apr 10 02:20:17 2022 | Patrick | DAQ | New mbs startup guide | Connecting to the rfio server and opening a file is included in '@startup' now. Since
 mbs crashes reliably every 3 or 4 runs, it
 |  | 
| 189 | Sat Apr  9 19:50:40 2022 | Carsten |  | New thresholds for ADC of DAQ2 (starting with file0117) | unsigned short caen_V785AH_threshold_mod0 [32] =
 {0x0100 , 0x0004 , 0x0003
 |  | 
| 188 | Sat Apr  9 19:09:57 2022 | Rodolfo | Laser | Optimization - Resonator of dye laser | I have tuned a bit the resonator of the dye laser.
 
 |  | 
| 186 | Sat Apr  9 16:55:19 2022 | Rodolfo | Laser |  | 16:15 I have changed the dye (of both oscillator and amplifier).
 
 |  | 
| 185 | Sat Apr  9 15:47:21 2022 | Carsten, Rodolfo, Sarper, Patrick | Runs | Afternoon and night shift runs | After the morning shift, we got new increment (nm) for the laser scanning. We are now scanning
 2 nm of wavelength range in 5 big steps (5
 |  | 
| 184 | Sat Apr  9 14:15:44 2022 | Kristian, Max, Konstantin | DAQ | Change in LV code | We changed the LV code so that the Cobra Set Wavelength is permanently sent. Before it
 was only sent once at the beginning of each
 |  | 
| 183 | Sat Apr  9 13:45:42 2022 | Max, Kristian | Runs | first scans with LV problem solved! | This is the first time with LV buffer problem solved (see Elog ID: 184). Before the PMT
 signals were out of sync with the wavelength
 |  | 
| 182 | Sat Apr  9 06:42:23 2022 | Kristian | Laser | Laser step size | We changed the laser step size to 0.002 nm which corresponds to 5.75 GHz.
 |  | 
| 181 | Sat Apr  9 06:25:22 2022 | Max, Kristian | Runs | morning shift runs | DAQ1: lxg1927:/data.local2/BeamTimeTh22/ DAQ2: lxg0155:/data.local2/E142/
 LMD file name DAQ1:229Thor
 |  | 
| 180 | Sat Apr  9 05:26:25 2022 | Patrick | Laser | Wavemeter | The wavemeter still shows large spikes from time to time. The exposure time is still
 at 34ms.
 |   | 
| 179 | Sat Apr  9 05:00:11 2022 | Carsten | General | Draft Docs and cheat sheet | Please check the attached files, 
 and correct or enhance them.
 |    | 
| 178 | Sat Apr  9 04:40:01 2022 | Patrick | DAQ | Bugged Trending plots? | The problem from yesterday (ID:147) still persists. All the plots (not only the labview
 stuff) comes in too late in go4. However,
 |   |