  197   Sun Apr 10 11:11:18 2022 Kristian, MaxLaseradditional WM readoutsince the WM readout still does not work reliably,
I started a python script at atppc023 that
saves timestamp and wavemeter frequency.
  
  196   Sun Apr 10 08:53:26 2022 Kristian, MaxLaserTiming verifiedtiming is still good.

we checked the relative timing between laser
  
  195   Sun Apr 10 06:39:16 2022 Kristian, Marek, MaxRunsruns morning shift 10.04.These are the measurement runs of the morning
shift (10.04.).
  
  194   Sun Apr 10 06:34:49 2022 Kristian, MaxDAQWavemeter ReadoutProblem solved. Ignore this entry

  
  193   Sun Apr 10 04:37:29 2022 PatrickDAQNext wavelength rangeMeasurements with the next wavelength scan
range should be started roughly around 12:00
noon. The plan is to go to lower wavelengths
 2022-04-10_calculations_323nm.jpg 
  192   Sun Apr 10 04:07:53 2022 PatrickDAQgo4 shows wrong frequencies and wavelengths[B]Update (ID:194):[/B] In labview "Stop All",
close labview, stop python script (ID:197),
close wavemeter. Then restart wavemeter,
 2022-04-10_measured_wavel.png2022-04-10_measured_wavel2.png2022-04-10_measured_wavel_go4.png 
  191   Sun Apr 10 03:56:56 2022 V. HannenDetectorsLow rate in PMT SouthPMT south shows a much lower count rate than
observed in elog entry 170.
 2022-04-10_PMTs_over_wavel-03_56.png 
  190   Sun Apr 10 02:20:17 2022 PatrickDAQNew mbs startup guideConnecting to the rfio server and opening
a file is included in '@startup' now. Since
mbs crashes reliably every 3 or 4 runs, it
  
  189   Sat Apr 9 19:50:40 2022 Carsten New thresholds for ADC of DAQ2 (starting with file0117)unsigned short caen_V785AH_threshold_mod0
[32] = 
                {0x0100 , 0x0004 , 0x0003
  
  188   Sat Apr 9 19:09:57 2022 RodolfoLaserOptimization - Resonator of dye laser I have tuned a bit the resonator of the dye
laser. 
  
  186   Sat Apr 9 16:55:19 2022 RodolfoLaser 16:15 I have changed the dye (of both oscillator
and amplifier).
  
  185   Sat Apr 9 15:47:21 2022 Carsten, Rodolfo, Sarper, PatrickRunsAfternoon and night shift runsAfter the morning shift, we got new increment
(nm) for the laser scanning. We are now scanning
2 nm of wavelength range in 5 big steps (5
  
  184   Sat Apr 9 14:15:44 2022 Kristian, Max, KonstantinDAQChange in LV codeWe changed the LV code so that the Cobra Set
Wavelength is permanently sent. Before it
was only sent once at the beginning of each
  
  183   Sat Apr 9 13:45:42 2022 Max, KristianRunsfirst scans with LV problem solved!This is the first time with LV buffer problem
solved (see Elog ID: 184). Before the PMT
signals were out of sync with the wavelength
  
  182   Sat Apr 9 06:42:23 2022 KristianLaserLaser step sizeWe changed the laser step size to 0.002 nm
which corresponds to 5.75 GHz.
  
  181   Sat Apr 9 06:25:22 2022 Max, KristianRunsmorning shift runsDAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
  
  180   Sat Apr 9 05:26:25 2022 PatrickLaserWavemeterThe wavemeter still shows large spikes from
time to time. The exposure time is still
at 34ms.
 2022-04-09_Wavemeter_during_scan5.png 
  179   Sat Apr 9 05:00:11 2022 CarstenGeneralDraft Docs and cheat sheetPlease check the attached files,

and correct or enhance them.
 e142_daq2_cabling.odsDocumentation_for_beamtime_2022_.doc 
  178   Sat Apr 9 04:40:01 2022 PatrickDAQBugged Trending plots?The problem from yesterday (ID:147) still
persists. All the plots (not only the labview
stuff) comes in too late in go4. However,
 2022-04-09_Cobra_set_wavelength2.png 
  177   Sat Apr 9 04:01:35 2022 Carsten 2nd DAQSwitched the CAEN TDC back on and changed
the threshoolds for the ADC to: 
  