150
Fri Apr 8 05:46:35 2022
V. Hannen
Detectors
High background rate in Cu PMT points to light leak in ESR or active pressure gauge
The background rate of the Cu mirror PMT is
only about 300 cps when the mirror is in
the parking position but ca. 7000 cps when
165
Fri Apr 8 14:46:02 2022
Danyal & Sebastian & Volker & Ken
Detectors
high dark countrate Cu PMT solved
The problem - "discovered" by Volker and Ken
- of the high dark countrate of the Cu PMT
has been solved.
191
Sun Apr 10 03:56:56 2022
V. Hannen
Detectors
Low rate in PMT South
PMT south shows a much lower count rate than
observed in elog entry 170.
217
Tue Apr 12 13:24:40 2022
Alexandre, Sebastian
Detectors
Sideband in Schottky
Sometimes we see a broad sideband at lesser
schottky frequencies to the high intensity
thorium beam.
218
Tue Apr 12 14:11:52 2022
Ragan
Detectors
Sideband in Schottky
> Sometimes we see a broad sideband at lesser
Schottky frequencies to the high-intensity
thorium beam.
219
Tue Apr 12 14:52:19 2022
Rodolfo
Detectors
PMT Nord, Middle. Datasheets
Attached are the datasheets for the solar-blind
PMTs.
221
Tue Apr 12 17:01:30 2022
Konstantin
Detectors
Voltage PMT North
Voltage of PMT North has been increased from
2500 V to 2600 V. Additionally the threshold
was adapted from 25 mV to 12 mV.
228
Thu Apr 14 12:27:18 2022
Sebastian, Max
Detectors
Connection to XUV / Cu reestablished!
The connection to the XUV and Cu were lost
during the nightshift.
229
Thu Apr 14 12:38:38 2022
Sebastian
Detectors
XUV / Cu checkups
Check regularly if the connection to the XUV
and Cu detectors are still active and the
detectors move in (after injection) and out
5
Fri Aug 6 10:23:00 2021
Rodolfo
DAQ
atplaser on r4l-41
The user [B]atplaser[/B] is now existing on
the [B]R4L-XY[/B] nodes for the ESR group.
6
Fri Aug 6 10:40:54 2021
Rodolfo
DAQ
mbs in atplaser
The "MBS program" (data acquisition) is now
located within atplaser@r4l-41, in the folder
"th21":
9
Fri Nov 5 17:23:23 2021
Rodolfo
DAQ
Dye trigger out
The dye laser offers different scan settings
(see pages 65 - 67 of the user manual). We
are using the following setting, see attached
15
Thu Mar 10 15:20:26 2022
Jan
DAQ
analog branch signal patches to Messhütte
The additional signals from PMTs and XUV detector
needed for spectroscopic analysis in the
second DAQ are patched to AP Messhütte (MH)
16
Wed Mar 16 08:31:52 2022
Kristian
DAQ
Check cables and timing
Konstantin and I generated a signal in the
Messhütte and sent it to the ESR.
There, we used a 44m BNC cable that was sufficently
21
Fri Mar 18 16:51:27 2022
Carsten
DAQ
Main DAQ /MBS error
MBS error "TDC data ready wait" solved. Common
stop trigger (20 kHz) was missing. (according
to Sebastian)
24
Mon Mar 21 10:46:18 2022
Rodolfo
DAQ
TDC & Scaler description channels
For the First Vuprom we have the following
channel configuration (Stand:21.03.2021).
25
Mon Mar 21 16:33:23 2022
DAQ
Changing code of go4
We agreed to indicate changes in the go4 analysis
code according to the
following scheme
26
Mon Mar 21 17:03:47 2022
DAQ
Changing code of go4
Correction: Comments in C/C++ start with //
, i.e. forward slash
27
Mon Mar 21 21:48:46 2022
Jan
DAQ
MesyTec Shaper Control
The MesyTec Shaper & Constant Fraction (MSCF)
is used to process the PMT/det signals for
the ADC in the second DAQ.
32
Thu Mar 24 13:27:47 2022
Rodolfo
DAQ
Disk space - LXG1297
In our Linux computer (LXG1297: Laser spectroscopy)
we have a Drive with 1.8 TB total disk space.
300 GB are at the moment in use, but I can