103
|
Tue May 31 21:08:04 2022 |
Carsten, Max | Detectors | XUV detector automation off |
We deactivated the automation of the XUV detector. It stays out now. |
104
|
Tue May 31 21:58:55 2022 |
Max, Rodolfo | Laser | MRC Settings for 209Bi |
We have change the laser settings for the spectroscopy of 209Bi.
We have now T-scraped the laser beam to the old position of the ion beam. The settings for the MRC system are shown in the screenshot below. |
Attachment 1: MRC_209Bi_31-05-2022_2157.png
|
|
105
|
Wed Jun 1 00:03:08 2022 |
Konstantin, Simon, Kristian | Runs | 209-Bi runs |
Time | SIS-intensity | ESR-intensity after orbit change | cooler-HV | cooler current (mA) | LMD-DAQ2 file nr | LMD-DAQ1 file nr | scan range(nm) | step width increment (nm) | dwell time(s) | n loops | comments
|
23:40 | - | - | 223432 | 100 | 781 | 8246 | 601.735 - 601.95 | 0.005 | 4.95s | 2 | resonance found but problems with go4
|
00:02 | - | 5.5e6 | 223432 | 100 | 783 | 8248 | 601.735 - 601.95 | 0.005 | 4.95s | 2 | resonance not in the middle of the scan range
|
00:14 | - | 4.5e6 | 223432 | 100 | 784 | 8249 | 601.7 - 601.9 | 0.005 | 4.95s | 2 | change the scan range
|
00:14 | - | 1.1e7 | 223432 | 100 | 785 | 8250 | 601.7 - 601.9 | 0.005 | 4.95s | 2 |
|
00:35 | - | 9e6 | 223432 | 100 | 786-787 | 8251 | 601.7 - 601.9 | 0.005 | 4.95s | 4 |
|
00:50 | - | 6.5e6 | 223432 | 100 | 788-789 | 8252 | 601.7 - 601.9 | 0.005 | 4.95s | 4 |
|
01:07 | 2.2e8 | 1.15e7 | 223432 | 100 | 790-791 | 8253 | 601.7 - 601.9 | 0.005 | 4.95s | 4 |
|
01:26 | 2.3e8 | 1.15e7 | 223448 | 200 | 792 | 8254 | 601.7 - 601.9 | 0.005 | 4.95s | 2 | switched to coasting beam, changed ESR current
|
01:37 | 2.2e8 | 1.15e7 | 223448 | 200 | 793 | 8255 | 601.7 - 601.9 | 0.005 | 4.95s | 2 |
|
01:48 | 2.2e8 | 1.15e7 | 223448 | 200 | 794 | 8256 | 601.7 - 601.9 | 0.005 | 4.95s | 2 |
|
01:58 | 2.2e8 | 1.15e7 | 223448 | 200 | 795 | 8257 | 601.7 - 601.9 | 0.005 | 4.95s | 2 |
|
02:08 | 2.2e8 | 1.15e7 | 223448 | 200 | 796 | 8258 | 601.7 - 601.9 | 0.005 | 4.95s | 2 |
|
02:19 | 2.15e8 | 1.15e7 | 223432 | 100 | 797-799 | 8259 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | changed ESR current again
|
02:45 | 2.17e8 | 1.15e7 | 223432 | 100 | 800-802 | 8260 | 601.7 - 601.9 | 0.005 | 4.95s | 6 |
|
03:12 | 2.12e8 | 1.15e7 | 223423 | 50 | 803-805 | 8261 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | changed cooler current again, restarted NTCAP folder 2022-05-31_19-33-57
|
03:38 | 2.2e8 | 1.15e7 | 223423 | 50 | 806-808 | 8262 | 601.7 - 601.9 | 0.005 | 4.95s | 6 |
|
04:05 | 2.13e8 | 1.15e7 | 223427 | 75 | 809-811 | 8263 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | changed cooler current again, restarted NTCAP folder 2022-06-01_03-12-03
|
04:30 | 2.03e8 | 1.15e7 | 223427 | 75 | 812-814 | 8264 | 601.7 - 601.9 | 0.005 | 4.95s | 6 |
|
04:57 | 2.08e8 | 1.15e7 | 223440 | 150 | 815-817 | 8265 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | changed cooler current again, restarted NTCAP folder 2022-06-01_04-04-32
|
05:21 | 2.1e8 | 1.15e7 | 223440 | 150 | 818-820 | 8266 | 601.7 - 601.9 | 0.005 | 4.95s | 6 |
|
05:57 | 2.08e8 | 1.15e7 | 223440 | 150 | 821-823 | 8267 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | laser power reduced from 46.2mJ to 25mJ
|
06:25 | 1.5e8 | 9e6 | 223440 | 150 | 824-826 | 8268 | 601.7 - 601.9 | 0.005 | 4.95s | 6 |
|
06:56 | 2.1e8 | 1.15e7 | 223440 | 150 | 827-829 | 8269 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | Laser power reset to 48mJ. Last ion injection!!!
|
07:18 | - | 4.7e6 | 223439 | 150 | 830-832 | 8270 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | Last ion injection!!!
|
7:40 | - | 2.0e6 | 223439 | 150 | 833-834 | 8271 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | old beam
|
8:02 | - | 1.0e6 | 223439 | 150 | 835-836 | 8272 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | older beam
|
8:25 | - | 5e5 | 223439 | 150 | 837-8 | 8273 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | very old beam
|
8:48 | - | 3e5 | 223439 | 150 | 839-840 | 8274 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | very very old beam
|
9:10 | - | 2e5 | 223439 | 150 | 841-842 | 8275 | 601.7 - 601.9 | 0.005 | 4.95s | 6 | beam close to retirement - no signal anymore
|
9:33 beam retired. Turned laser off. Stopped NTcap
post beamtime change: replaced "ESR current" by "cooler current" in the comments column. (Wilfried) |
106
|
Wed Jun 1 00:16:02 2022 |
Konstantin, Simon | DAQ | Timing 209Bi thick target |
Timing for the final measurements on 209Bi was determined for the new frequency 1.93777MHz. Peak positions are
PD NO 106
PD SO 141.5
PMT MIDDLE 45 (due to the broad temporal structure difficult to determine)
Center between PDs is 123.75. Difference to PMT MIDDLE is 78.75. This is ~3 bins larger than the half period of 75. |
Attachment 1: Timing_209Bi_final.png
|
|
107
|
Wed Jun 1 08:39:50 2022 |
Kristian, Konstantin | Calibration | Wavemeter reading |
We recorded files with high wavemeter readout rate and saved it at the atplaser network drive (Q:) - Bismuth - wavemeter folder.
Could be used to calibrate the laser steps. The MBS readout rate is 4 Hz, here 30 Hz, so there are a few more values. |
108
|
Wed Jun 1 17:20:04 2022 |
Rodolfo | Laser | HeNe @ WS7 |
|
Attachment 1: HeNe_WS7_01-06-2022_1.png
|
|
109
|
Fri Jun 3 12:01:17 2022 |
Danyal | Detectors | switched off XUV detector on 1 June ~17:00 |
I have switched off the XUV detector on 1 June at about 17:00.
The high voltages of the MCP (in ESR laser lab) were turned off and inside the ESR cave the power supplies (coils and cathode) and the crate were turned off.
Also the new "control box" for the detector was switched off.
And I checked (visually) that the XUV detector (and the Cu detector too) were indeed "moved out".
Danyal |
110
|
Thu Jun 30 11:12:21 2022 |
Carsten | Analysis | Updated Go4 Analysis with small Bugfix (PMTOverWavelength SPectra) |
Here attached is a more recentversion of the Go4 Analysis Code with some smaller bugfixes.
For adaequate *.C files please have alook in 208Bi go4 directory on the atplaser account.
Please note, that there is also a (not fully up-to-date) description/manual somewhere here in the Elog. |
Attachment 1: 208Bi_20220629_fix.tgz
|
111
|
Fri Jan 13 17:05:22 2023 |
Rodolfo | Laser | Testing WS6 |
Testing the new Wavemeter (HighFinesse, WS6, SN3950) with the QRAY laser light @ 532 nm. Multimode fiber von High Finesse:FC/PC S (Corning, MM, OM2) |
Attachment 1: WS6_3950_QRayWavelength_13-01-2022.png
|
|
112
|
Wed Jan 18 13:02:12 2023 |
Rodolfo | Laser | Testing WS6 with Cobra |
Testing the WS6 (S.N. 3950) together with the Cobra.
Cobra operated with dye DCM in Ethanol + DMSO (Concentration 1:1)
- Oscillator concentration 0.3 g/l.
- Main amplifier concentration 0.0375 g/l (1/8 oscillator concentration).
- Laser linewidth: 6 GHz. Expansion factor: 10x. Grating: 2400 g/mm (40/2013)
Seed energy: 504 mJ @ 532 nm.
Cobra output energy: 112 mJ @ 640 nm.
Scan settings: 640.0 nm - 639.8 nm @ 0.005 nm / step.
Wavemeter settings: Pulsed (ext. trigg. 1 = QRay-Output: Lamp Sync). Precision: Fine.
- Wavemeter calibration. Reference source: Neon lamp.
- LTA-Data under ATPPC023 D:\WLM6 LTA data\D:\WLM6 (18.01.2023, 11.23, 640,10656 nm.lta) |
Attachment 1: WS6_640-639.8_0.005_18-01-2023_11.23.png
|
|
113
|
Tue Jun 6 09:33:00 2023 |
Rodolfo | Laser | Fiber coupler |
Cobra's new fiber-coupling unit for wavelength reading. |
Attachment 1: Cobra_FiberCoupler.jpg
|
|