Wed Jun 26 11:59:12 2024, Ruijiu, Shahab, Carsten, Analysis, Prepare plots for Thomas's presentation 6x 
 | 
data:
 
(env_OnlineDataAnalysisSystem) litv-exp@lxbk0497:/lustre/astrum/experiment_data/2024-05_E018/OnlineDataAnalysisSystem/data/iq/IQ_2024-06-
 
12_21-47-54$
 | 
   Sat Jun 15 03:46:34 2024, Night shift, Accelerator, GSI down 
 | 
All quadrupole and dipole magnets at SIS and ESR are out of order. Repairs can be expected earliest tomorrow evening. No shifts will take place before 6pm. 
Have a look at your mails for details. | 
   Fri Jun 14 14:44:51 2024, Afternoon shift, Runs, Afternoon shift 
 | 
Pizza shift
 
 
[B]the scan direction is from higher wavelength to lower wavelength, even though it is noted otherwise here in the software.
 | 
   Fri Jun 14 13:14:29 2024, Konstantin, Bernhard, Peter, Lukas, General, DAQ crashes at :10 
 | 
10 Minutes past a full hour (XX:10) the windows PCs (sometimes) loose connection.
 
This causes the labview server & the laser remote ctrl  to crash.
 
 | 
   Fri Jun 14 11:44:23 2024, Carsten Brandau, Accelerator, Cooling Time in SC7 increased from 9s to 12s 
 | 
| Cooling Time in SC7 increased from 9s to 12s | 
   Fri Jun 14 06:38:41 2024, Konstantin Mohr, Bernhard Maass, Peter Micke, Lukas Kau, Dounia Boudefla, Runs, Morning runs 
 | 
Very successful shift, no crashes until 11:10
 
Previous night shift had problems with the pulse laser starting around 3am.
 
Something was loose at the FCU. Rodolfo was called in and was able to fix it.
 | 
   Thu Jun 13 22:08:07 2024, Dayshift, Accelerator, Problems with Accelerator?    
 | 
It seems to be that there are some problems with the injections in the ESR.
 
The last 2 accumulation cycles showed that wheter only a small amount of ions are injected into the ESR or the injection is missing.
 
 | 
   Thu Jun 13 18:48:26 2024, Ruijiu Chen, David, Shahab, Yuri, Analysis, The ion identification of 229Th is correct.   
 | 
Harmonic: 124.0 , Bp: 7.796046 [Tm]
 
ion            fre[Hz]                       yield [pps]    
 
------------------------------------------------------------
 | 
   Thu Jun 13 18:38:24 2024, Rodolfo Sanchez, Julian Palmes, Sebastian Klammes, Laser, Laser Dye change - new MRC settings - scraper checks of laser beam  
 | 
We changed the dye at ~3pm.
 
 
After some fine adjustements of the laser we had to change the MRC settings, because the laser position changed.
 | 
   Thu Jun 13 18:23:46 2024, Julian, Laser, Restarting the laser controller 
 | 
If the laser controller is locked up again, the little display will show an error message after an attempted medusa scan.
 
To restart it, follow these steps:
 
1.) Unlock the beam stabilization.
 | 
   Thu Jun 13 18:03:36 2024, Afternoon shift, Runs, Continuation: First scans   
 | 
[TABLE border="1"]
 
Time | Part. Det. Int | ESR-intensity| cooler-HV | LMD-DAQ1 Files | LMD-DAQ2 Files | scan range(nm) | number of positions | dwell time(s) | n loops | comments
 
|-
 | 
   Thu Jun 13 14:56:09 2024, Stefan Schippers, Accelerator, Estimated beam lifetime: About  150 s 
 | 
Estimate of storage lifetime using my code 'hydrocal':
 
 
 ion mass in u ...................................: 229
 | 
   Thu Jun 13 14:41:22 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 13 9:00~11:00  
 | 
|   | 
   Thu Jun 13 14:35:27 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 13 7:00~9:00  
 | 
|   | 
   Thu Jun 13 14:20:36 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 13 4:30:7:00  
 | 
|   | 
   Thu Jun 13 13:29:47 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 12 22:00- June 13 0:00  
 | 
|   | 
   Thu Jun 13 12:37:14 2024, Ruijiu Chen, David, Analysis, Lifetime of beam in center of mass is 193 s.  
 | 
|   | 
   Thu Jun 13 12:05:31 2024, Konstantin, Peter, Jonas, Accelerator, RF-amplitude   
 | 
To realize the shortest bunches possible, we check the bunch length as a function of two different bunching amplitudes. With the bucket fill set to 1.0 
we observe the spectra compiled in attachment 1. The second attachment is recorded with a bucket fill 0f 0.2.
 
 | 
   Thu Jun 13 10:42:02 2024, Danyal, General, Question 
 | 
What is the ion beam lifetime, according to the DCCT and Schottky? 
 
Can somebody measure it, please? 
 
Yesterday we could not see a fast drop in the "main" beam. 
 | 
   Thu Jun 13 10:32:29 2024, Konstantin, Accelerator, (Proper) Cooler settings 
 | 
We change the acceleration voltage of the electron cooler and observe the platform high voltage and the count rate at the particle detector south.
 
Cooler current at 100mA.
 
 |