Entry  Sat Jun 8 13:11:52 2024, Carsten, General, Put the go4login in atplaser .bashrc 
Put the go4login in atplaser .bashrc in order to avoid that one always has to go to the go4 directory to set the environment variable.
go4login64 is now executed automaticlally and the environments are now set every time you open a (bash) shell.
A fixed version 6.3 is used. The login file might be changed back after the beamtime.
Entry  Sat Jun 8 12:45:05 2024, Carsten, DAQ, Temporary change of RF signal 
The setting was 1.540974 MHz and division factor 68 (for a 200 MeV/u) beam, and the signal was taken from a signal generator.
I now switch to the "real" RF signal from the accelerator (~400MeV/u), that is 1.9693 MHz and the factor is set to 88.
This should be set back for laser tests or adjusted when we have the real decellerated beam.
Entry  Sat Jun 8 12:02:20 2024, Carsten, Detectors, Test Particle Detectors - Det South not working 
With the test beam from ESR I started to have a look at the PartDets.:
North outside: Works properly with a voltage of 1450 V
South outside (behind cooler) : no signal.
Entry  Fri Jun 7 17:10:45 2024, Sebastian, General, XUV LED 
Maximum XUV LED Voltage: 6.5V
Entry  Fri Jun 7 15:29:50 2024, Rodolfo, Detectors, Stored beam @ ESR Storedbeam@ESR_2024-06-07_15-25-18.png
One of the first PMT signals from the stored-ion beam @ ESR
Entry  Fri Jun 7 11:14:04 2024, Rodolfo, Laser, Trigger-signal for MRC MRC_TriggerSignal_T1_06-06-2024.jpgMRC_TriggerSignal_T2_Tmin_06-06-2024.jpgGeneratorSettings_for_MRC_06-06-2024.jpgMRC_Parameters_06-06-2024_18-30.JPG
We are using a 2-Channel Function Generator (from Textronik) to generate the trigger signal for the MRC Beam Stabilization. 

The triggers are (according to the MRC nomenclature):
Entry  Fri Jun 7 09:15:31 2024, Carsten, DAQ, Updated Channel List ChannelList.pdfChannelList.odt
 
Entry  Thu Jun 6 19:51:11 2024, Carsten, Accelerator, ESR crew left after persisting problems with ESR magnets 
No beam today.--.
Entry  Thu Jun 6 19:47:01 2024, Carsten, DAQ, Exchange of Mesytec CFD/shaper - noise on signal lines from ESR magnets 
Jan exchanged the Mesytec CFD/shper since it could not be "remote controlled" anymore. The new one has different shaping times and delays.
It is noted the threshold range is rather small. 
With the new  shaper only the x100 signals could meaningfully discriminated etc.
Entry  Thu Jun 6 19:42:20 2024, Carsten, Detectors, Exchange of amplifer channels / cables channels / HV voltage cables for PMT south 
In order to check if the problem of regular burst of pulses on the PMT south is related to amplfier channels and or the HV cable, the cheannels of the amplifiers
in the ESR were changed. Likewise, a different HV cable is now used for the supply of the PS.
Entry  Thu Jun 6 09:39:23 2024, Carsten, DAQ, Preliminary Channel Table (DAQ1 and DAQ2) ChannelList.pdfChannelList.odt
 
Entry  Thu Jun 6 09:23:53 2024, Konstantin Mohr, DAQ, Timing TimingSSH.pngDualTimer.jpegTimingAdjustment.JPG
The best way to adjust the bunch-laser timing is to start go4 (mbs must be running) from atppc023. Therefore use x2goclient and use the predefined session
to access LXG1297. Start go4 as usual ([URL=https://elog.gsi.de/esr/E0052/10]Entry 10[/URL] + [URL=https://elog.gsi.de/esr/E0052/11]Entry 11[/URL]). 
Entry  Thu Jun 6 08:16:36 2024, Danyal, Accelerator, scraper info by Robert Boywitt Scraper_im_Cooler.pdfT_Scraper_ECEDS1__.PNGT_Scraper_ECEDS2__.PNGT_Scraper_ESR.JPEG
attched is more info about the T-scrapers (E-cooler) by Robert Boywitt (Tel: 2067 or 3357)
Entry  Thu Jun 6 07:54:15 2024, Danyal, General, pressure gauges and ion pumps  
yesterday (05.06.2024), firstly, the two ion pumps (underneath the fluorescence chamber) were switched off by the vacuum group (Björn Mai, Tel: 3438).
Secondly, the two pressure gauges (located near the target) were switched off.  The pressure gauge at the fluo chamber is called E02VM3x and the pressure
was 5.5e-11 mbar.  The other gauge is called IG2 and located further south, it measured 3.7e-11 mbar.  That was when ion pumps were still switched on.
Entry  Thu Jun 6 07:12:49 2024, Konstantin Mohr, Laser, T-Scraper 6x
The T-Scrapers can be driven by DeviceControl, which must be started from a console. To do so, first open the app-launcher and then select "Device Control",
which is found under "Betrieb & Steuerung". Then select the appropriate context (should be the name of the experiment). After a short time the device icons
will be present. The scrapers can be found in the last four columns and the second last row (see screenshot 1). By default, they should be colored like
Entry  Wed Jun 5 19:22:43 2024, Carsten, Konstantin, Rodolfo, Detectors, PMT tests and preliminary thresholds SolarBlind_ET_9422_SN1042.pdfVoltagePMTs_05-06-2024.jpg
For all channels of the CAEN CFD the width of the logic signal is set to 255ns (maximum) to mitigate potential double pulses. For the very low count rates
of the experiment this is not problem.
Entry  Wed Jun 5 14:17:36 2024, Carsten, Accelerator, Distance Cooler Detector 
Calculation from Helmut Weick (copied from E142)
Distance e-cooler to particle detectors chamber:
“This is half of ESR plus distance target - detector. This even is on the web page”
Entry  Tue Jun 4 22:54:02 2024, Rodolfo, Detectors, PMT - Manufacture - Test Result Data PMT_9423B_SN652_ETEnterprises_UniGießen.pdfPMT_9423B_SN653_ETEnterprises_TUDA.pdfPMT9422_SN1049_Datenblatt.pdf
 
Entry  Mon Jun 3 19:42:06 2024, Rodolfo, Laser, Laser-beam through E-Cooler LaserBeam-at-Screen_ESR-NO_08-06-2024.JPG
UV-laser beam is now going through the Electron-Cooler. 

Telescope settings:
Entry  Mon Jun 3 18:24:44 2024, Rodolfo, Detectors, PMT arrangement PMT_Arrangement_2024-06-03.jpgHV-Powersupply_PMTs_Thorium2024.jpg
The picture shows the actual configuration of the PMTs.

We are using a 4-Channel High-Voltage supply. The channels are labeled according to the PMTs names.