ID |
Date |
Author |
Category |
Subject |
Year |
Text |
 |
336
|
Thu May 13 21:22:31 2021 |
Jan Glorius | Calibration | run0039 - Xray145 calib Pb210 d=305mm | 2021 | Efficiency calibration in the lab
************************************
|
|
335
|
Thu May 13 17:38:13 2021 |
Jacobus Swartz | Calibration | Runlist for X-ray detector calibrations | 2021 | Here is a run summary of all the calibration
measurements performed so far on the three
X-ray detectors. |
|
334
|
Thu May 13 14:16:58 2021 |
Jan Glorius | Calibration | run0038 - Xray145 calib Pb210 d=305mm | 2021 | Efficiency calibration in the lab
************************************
|
|
333
|
Thu May 13 13:24:44 2021 |
Jan Glorius | Calibration | run0037 - Xray90 calib Pb210 d=167.5mm | 2021 | Efficiency calibration in the lab
************************************
|
|
332
|
Thu May 13 12:21:41 2021 |
Jan Glorius | Calibration | run0036 - Xray90 calib Ba133_lo d=167.5mm | 2021 | Efficiency calibration in the lab
************************************
|
|
331
|
Thu May 13 12:06:51 2021 |
Jan Glorius | Calibration | run0035 - Xray90 calib Cd109 d=167.5mm | 2021 | Efficiency calibration in the lab
************************************
|
|
330
|
Thu May 13 11:51:42 2021 |
Jan Glorius | Calibration | run0034 - Xray90 calib Am241_hi d=167.5mm | 2021 | Efficiency calibration in the lab
************************************
|
|
329
|
Wed May 12 15:28:55 2021 |
Jan Glorius | Calibration | run0033 - Xray145 calib Cd109 d=305mm | 2021 | Efficiency calibration in the lab
Detector: GEM3000 - 145 deg
|
|
328
|
Wed May 12 14:55:04 2021 |
Jan Glorius | Calibration | run0032 - Xray90 calib Cd109 d=167.5mm | 2021 | Efficiency calibration in the lab
************************************
|
|
327
|
Wed May 12 14:16:27 2021 |
Jan Glorius | Calibration | run0031 - Xray90 calib Am241_hi d=167.5mm | 2021 | Efficiency calibration in the lab
|
|
326
|
Wed May 12 13:36:24 2021 |
Jan Glorius | Calibration | run0030 - Xray90 calib Am241_hi d=167.5mm | 2021 | Efficiency calibration in the lab
AMPLIFIER JUMPED!
|
|
325
|
Wed May 12 11:47:41 2021 |
Jan Glorius | Calibration | run0029 - Xray90 calib Pb210 d=167.5mm | 2021 | Efficiency calibration in the lab
************************************
|
|
324
|
Wed May 12 11:34:11 2021 |
Jan Glorius | Calibration | run0027 - crap | 2021 | |
|
323
|
Wed May 12 11:29:23 2021 |
Jan Glorius | Calibration | run0028 - Xray90 calib Ba133_hi d=167.5mm | 2021 | Efficiency calibration in the lab
************************************
|
|
322
|
Wed May 12 10:16:10 2021 |
Jan Glorius | Calibration | run0026 - Xray145 calib Ba133_hi d=305mm | 2021 | Efficiency calibration in the lab
Detector: GEM3000 - 145 deg
|
|
321
|
Tue May 11 16:49:23 2021 |
Jan Glorius | Calibration | run0025 - Xray145 calib Pb210 d=305mm | 2021 | Efficiency calibration in the lab
Detector: GEM3000 - 145 deg
|
|
320
|
Tue May 11 14:11:40 2021 |
Jan Glorius | Calibration | run0024 - Xray145 calib Am241_hi d=305mm | 2021 | Efficiency calibration in the lab
Detector: GEM3000 - 145 deg
|
|
319
|
Thu May 6 21:15:06 2021 |
Jan Glorius | Calibration | run0022 - Xray35 calib Pb210 d=334mm | 2021 | Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
|
|
318
|
Thu May 6 14:30:35 2021 |
Jan Glorius | Calibration | run0021 - Xray35 calib Pb210 d=334mm | 2021 | Efficiency calibration in the lab
Detector: GLP2000 - 35 deg
|
|
317
|
Thu May 6 13:39:02 2021 |
Jan Glorius | Calibration | efficiency xray 35deg | 2021 | the attached efficiency curve for the 35 deg.
xray detector is made with the runs
e127b_run0015.lmd
|
 |