HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  proton-capture on 118Te, Page 13 of 29  Not logged in ELOG logo
Entry  Thu May 13 21:22:31 2021, Jan Glorius, Calibration, run0039 - Xray145 calib Pb210 d=305mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Thu May 13 17:38:13 2021, Jacobus Swartz, Calibration, Runlist for X-ray detector calibrations, 2021 E127_Runlist-calibrations-4-3.xlsx
Here is a run summary of all the calibration measurements performed so far on the three X-ray detectors. 
Entry  Thu May 13 14:16:58 2021, Jan Glorius, Calibration, run0038 - Xray145 calib Pb210 d=305mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Thu May 13 13:24:44 2021, Jan Glorius, Calibration, run0037 - Xray90 calib Pb210 d=167.5mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Thu May 13 12:21:41 2021, Jan Glorius, Calibration, run0036 - Xray90 calib Ba133_lo d=167.5mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Thu May 13 12:06:51 2021, Jan Glorius, Calibration, run0035 - Xray90 calib Cd109 d=167.5mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Thu May 13 11:51:42 2021, Jan Glorius, Calibration, run0034 - Xray90 calib Am241_hi d=167.5mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Wed May 12 15:28:55 2021, Jan Glorius, Calibration, run0033 - Xray145 calib Cd109 d=305mm, 2021 
Efficiency calibration in the lab

Detector: GEM3000 - 145 deg
Entry  Wed May 12 14:55:04 2021, Jan Glorius, Calibration, run0032 - Xray90 calib Cd109 d=167.5mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Wed May 12 14:16:27 2021, Jan Glorius, Calibration, run0031 - Xray90 calib Am241_hi d=167.5mm, 2021 
Efficiency calibration in the lab

Entry  Wed May 12 13:36:24 2021, Jan Glorius, Calibration, run0030 - Xray90 calib Am241_hi d=167.5mm, 2021 
Efficiency calibration in the lab

AMPLIFIER JUMPED!
Entry  Wed May 12 11:47:41 2021, Jan Glorius, Calibration, run0029 - Xray90 calib Pb210 d=167.5mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Wed May 12 11:34:11 2021, Jan Glorius, Calibration, run0027 - crap, 2021 
 
Entry  Wed May 12 11:29:23 2021, Jan Glorius, Calibration, run0028 - Xray90 calib Ba133_hi d=167.5mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Wed May 12 10:16:10 2021, Jan Glorius, Calibration, run0026 - Xray145 calib Ba133_hi d=305mm, 2021 
Efficiency calibration in the lab

Detector: GEM3000 - 145 deg
Entry  Tue May 11 16:49:23 2021, Jan Glorius, Calibration, run0025 - Xray145 calib Pb210 d=305mm, 2021 
Efficiency calibration in the lab

Detector: GEM3000 - 145 deg
Entry  Tue May 11 14:11:40 2021, Jan Glorius, Calibration, run0024 - Xray145 calib Am241_hi d=305mm, 2021 
Efficiency calibration in the lab

Detector: GEM3000 - 145 deg
Entry  Thu May 6 21:15:06 2021, Jan Glorius, Calibration, run0022 - Xray35 calib Pb210 d=334mm, 2021 
Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
Entry  Thu May 6 14:30:35 2021, Jan Glorius, Calibration, run0021 - Xray35 calib Pb210 d=334mm, 2021 
Efficiency calibration in the lab

Detector: GLP2000 - 35 deg
Entry  Thu May 6 13:39:02 2021, Jan Glorius, Calibration, efficiency xray 35deg, 2021 35deg_eff.png35deg_eff.dat
the attached efficiency curve for the 35 deg. xray detector is made with the runs
e127b_run0015.lmd
e127b_run0016.lmd
ELOG V3.1.5-fc6679b