HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
proton-capture on 118Te, Page 13 of 29
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
General
Collaboration
Runs
Detectors
Simulations
Accelerator
572 Entries
Goto page
Previous
1
,
2
,
3
...
12
, 13,
14
...
27
,
28
,
29
Next
ID
Date
Author
Category
Subject
Year
Text
47
Sun Mar 15 17:12:40 2020
Laszlo, Jan
Detectors
new Ortec spec amps
We are now using new SpecAmps for the x-ray
detectors from ORTEC, they deliver much improved
resolution but have other strange effects
368
Fri May 21 19:20:54 2021
Laszlo
General
misalignment in the pattern
2021
for some reason the event number of the target
ON and OFF was misaligned with the pattern.
This means that the last few runs (run53,
269
Thu Mar 26 12:05:22 2020
Laszlo
Calibration
measurement of collimators
The measurements were taken by using a caliper
ruler, with precision of +/-0.05mm
6
Fri Apr 5 06:05:55 2019
Jan
DAQ
making changes to the DAQ
If you need to add or change a module of the
VME crate you need to follow this proceedure:
274
Wed Apr 8 23:02:24 2020
Laszlo
General
lmd to measurement pairing list
I use the following list of lmd files combined
to a single root file for each measurement.
It is very important to highlight that sometimes
439
Tue May 25 08:36:15 2021
Jan
General
lessons learned
2021
1. before using stoch. cooling in ESR, boot
and update the windows PC
2. better diagnostics for low energy/intensity
280
Thu Apr 30 22:55:45 2020
Laszlo
Calibration
inverse square law test
I have made also the inverse square law fits.
We have data only for 90degre with the 241Am
source, but both for the 1. and 2. calibrations.
134
Sat Mar 21 15:30:34 2020
Sergiy
General
go into the ESR
We are going into the ESR to check the electronics.
Use calibration sources (133Ba etc).
84
Fri Mar 20 16:48:00 2020
Laszlo
General
flipped Si shaper output in x and y
Yesterday evening we have found out that the
energy signals from the silicon are negative
--> wrong polarity of the shapers was chosen
233
Mon Mar 23 09:47:05 2020
Laszlo
General
explanation of an ESR cycle
345
Sun May 16 12:55:48 2021
Jan Glorius
DAQ
event server lxg1299:6003
2021
new event server is set up at lxg1299 on port
6003
It runs as:
304
Sat May 1 22:34:16 2021
Jan Glorius
Calibration
efficiency xray 90deg
2021
the attached efficiency curve for the 90 deg.
xray detector is made with the runs
e127b_run0008.lmd
317
Thu May 6 13:39:02 2021
Jan Glorius
Calibration
efficiency xray 35deg
2021
the attached efficiency curve for the 35 deg.
xray detector is made with the runs
e127b_run0015.lmd
281
Wed May 6 23:02:42 2020
Laszlo
Calibration
efficiency values
I have calculated the efficiency values by
putting the energies of the K-REC peaks into
the phenomenological (empirical) function
279
Thu Apr 30 17:40:57 2020
Laszlo
Calibration
efficiency fits
For all 3 detector the calibration data sets
were combined to include the systematics
in the fit results directly. Combining means
278
Wed Apr 29 16:06:28 2020
Laszlo
Calibration
efficiency fit - 90degree, combined dataset
For the efficiency vs E fit of the 90degree
Xray detector I have used the following phenomenological
funciton:
191
Sun Mar 22 14:58:59 2020
Laszlo
General
dropping density of Gasjet
after like 20min run, the density of the gasjet
already dropped from 10^14 to 8.7*10^13.
Now it seems to remain in that value
97
Sat Mar 21 02:36:44 2020
Laszlo
General
detector and scraper position
For the 124Xe primary beam measurement:
-with the DSSSD we scraped the beam at position
-40
36
Fri Feb 21 11:29:59 2020
Jan
Detectors
det. distances at target chamber
This is the lookup table for the distance
of each x-ray detector to the target.
See attched foto for explanation.
60
Tue Mar 17 08:15:49 2020
Jan
General
current grids & screen in TE
measured beam diagnosis with 124Xe48+ at 326
MeV/u