  388   Sat May 22 16:29:07 2021 Laszlo et al.Generalcoolers are back2021we can measure again.

(please write a detailed description if needed)
  
  577   Wed Jul 14 14:46:05 2021 Jan, SophiaDetectorscollimator geometry2021We have measured the collimator geometry.
The annotations of the variables can be found
in the attached sketch  
 10x 
  149   Sat Mar 21 22:57:28 2020 Laszlo, JanDAQchanging cables of the Xray 90 and 145 Energy signals of 90 and 145 degree detector
have been checked and exchanged
They were connected to the wrong ADC channel.
  
  543   Sat May 29 13:43:39 2021 Tino, Rene, Yuri, Laszlo, MarkusRunschange of settings2021from now on, everal beam setting will be different.
We could not get the beam back to were it
was before. When the scraper was pulled back
  
  293   Thu Apr 29 20:32:52 2021 Jan GloriusCalibrationcalibration sources2021We use the following list of sources for calibration
of the Xray detectors:
  
  31   Thu Jan 23 16:35:47 2020 LaszloDAQcable documentation    cable_documentation_e127.pdfcable_documentation_e127.ods 
  34   Fri Feb 21 09:39:40 2020 LaszloDAQcable documentation    cable_documentation_e127.pdfcable_documentation_e127.ods 
  40   Wed Mar 11 14:33:44 2020 LaszloGeneralbeam time manual Here you can find the digital version of the
E127 beam time manual.
 E127_experimental_manual.pdfmanual.odt 
  272   Mon Apr 6 23:00:51 2020 LaszloCalibrationbeam energies for 124Xe and 118Te measurements "The e- cooler settings were the same for
the 124Xe and 118Te beams" - Sergey --> speed
of the ions is the same --> same MeV/u
 SP54120040623030.pdf 
  576   Thu Jul 8 14:07:19 2021 JanCalibrationbeam energies2021Table of ion energies calculated from cooler
parameters
 CodeCogsEqn.pngCodeCogsEqn(1).png 
  357   Thu May 20 17:31:50 2021 Jan, Laszlo, BeatrizGeneralbeam & target alignement2021beam and target alignement was checked by
looking at the Xray rates. Best case when:
Target bump (position) SC 9: -18.5mm
  
  21   Thu Aug 29 10:02:22 2019 JanDetectorsbakeout at ESR setup The bakeout for our detector setup has started
on the evening of 27.08.2019 
We have a temperature sensor in the vacuum
 T_set_bakeout.png 
  227   Mon Mar 23 07:56:51 2020 LaszloGeneralYuri made magick and we operate again DSSSD was moved out (HV switched off)
also the scraper was mistakenly moved.
  
  204   Sun Mar 22 19:49:12 2020 Michael, Laszlo, Yuri Yuri is still tuning FRS We filled the Xray detectors.
Yuri is sill tuning FRS for primary beam.
  
  469   Wed May 26 14:28:23 2021 JanAnalysisXrays from 118Te & 124Xe2021Attached is a plot of the uncalibrated energy
spectra taken with the 90 degree xray detector
for 118Te (red) and 124Xe (blue).
 xray90_124Xe_118Te.png 
  86   Fri Mar 20 16:58:02 2020 JanDAQXray2 & Xray3 cabling We found that Xray2 and Xray3 the cabling
is not consistent:
  
  307   Tue May 4 14:34:51 2021 Jan GloriusDetectorsXray weight control induces signals2021When the readout/control of the det. weight
control via serial connection is active,
there is a clear signal induced in the Xray
  
  344   Sun May 16 11:54:12 2021 Jan GloriusCalibrationXray performance in lab2021These are the current Xray detector performances
in the lab using data from run0046
  
  297   Fri Apr 30 10:55:34 2021 Jan GloriusDAQXray multi-triggers - blocking gate2021From the CFD of Xray1 (90deg) we get multiple
trigger signals every ~5sec for unknown reasons.
  
  305   Mon May 3 14:55:44 2021 Jan GloriusCalibrationXray energy calib. table2021Here is the table of energy calibration lines
from Am241 for all Xray detectors for several
measurements.
  