Sat Mar 21 06:29:36 2020, Tino, Oliver, Runs, run entry - run055,
|
Open file: runstart055
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 06:29 , first file: run055_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 06:29 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 36 Hz
Xray_145: 25 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 4.04 uA
SIS particles before: 2.3e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.36e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 07:00:18 2020, Ragan, RuiJiu, Tino, Oliver, Runs, run entry - run055,
|
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 06:30 , first file: run055_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 7:00 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 31 Hz
Xray_145: 42 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 4.04 uA
SIS particles before: 3.6e9
ESR particles at injection: estimated ~10^5 - 10^4
ESR particles after decel.:
Target ON density: 1.49e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 07:30:19 2020, Ragan, RuiJiu, Runs, run entry - run056,
|
Open file: runstart056
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 7:30 , first file: run056_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 7:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 32 Hz
Xray_145: 41 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 4.04 uA
SIS particles before: 3.2e9
ESR particles at injection: estimated ~1.2e6
ESR particles after decel.:
Target ON density: 1.61e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 08:01:03 2020, Ragan, RuiJiu, Runs, run entry - run056,
|
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 07:30 , first file: run056_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 8:00 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 38 Hz
Xray_145: 23 Hz
BaF_OR: - Hz
Si voltage: 60.02 V
Si leakage current: 4.02 uA
SIS particles before: 3.3e9
ESR particles at injection: estimated ~1.02e6
ESR particles after decel.:
Target ON density: 1.7e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 08:31:27 2020, Ragan, RuiJiu, Runs, run entry - run057,
|
Open file: runstart057
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 8:30 , first file: run057_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 8:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 12 Hz
Xray_90: 83 Hz
Xray_145: 70 Hz
BaF_OR: - Hz
Si voltage: 60.01 V
Si leakage current: 4.04 uA
SIS particles before: 3.2e9
ESR particles at injection: estimated ~1.3e6
ESR particles after decel.:
Target ON density: 1.53e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 09:00:29 2020, Ragan, RuiJiu, Runs, run entry - run057,
|
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 08:30 , first file: run057_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 9:00 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 46 Hz
Xray_145: 35 Hz
BaF_OR: 15Hz
Si voltage: 60.02 V
Si leakage current: 4.03 uA
SIS particles before: 3.4e9
ESR particles at injection: estimated ~1.3e6
ESR particles after decel.:
Target ON density: 1.5e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 09:30:32 2020, Ragan, RuiJiu, Alex, Runs, run entry - run058,
|
Open file: runstart058
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 9:00 , first file: run058_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 9:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 49 Hz
Xray_145: 19 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.03 uA
SIS particles before: 3e9
ESR particles at injection: estimated ~1.1e6
ESR particles after decel.:
Target ON density: 1.56e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 10:00:19 2020, Ragan, Alex, Runs, run entry - run058,
|
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 09:30 , first file: run058_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 10:00 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 1 Hz
Xray_90: 32 Hz
Xray_145: 19 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.03 uA
SIS particles before: 3.2e9
ESR particles at injection: estimated ~1.1e6
ESR particles after decel.:
Target ON density: 1.716e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 10:20:27 2020, Ragan, Alex, General, Target LN2,
|
The LN2 Dewar on the ESR roof has been refilled. |
Sat Mar 21 10:28:23 2020, Ragan, Alex, Runs, run entry - run059,
|
Open file: runstart059
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 10:30 , first file: run059_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 10:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 0 Hz
Xray_90: 40 Hz
Xray_145: 15 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.00 uA
SIS particles before: 3.2e9
ESR particles at injection: estimated ~1.3e6
ESR particles after decel.:
Target ON density: 1.59e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 11:04:47 2020, Ragan, Alex, Laszlo, Runs, run entry - run059,
|
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 10:30 , first file: run059_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 11:07 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 2-3 Hz
Xray_90: 29 Hz
Xray_145: 17 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.04 uA
SIS particles before: 2.5e9
ESR particles at injection: estimated ~1.3e6
ESR particles after decel.:
Target ON density: 1.34e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 11:25:47 2020, Laszlo, , possible misalignement between target and fragment beam,
|
after 9hours of measurement we see only 19 counts on our targetON silicon detector histo. this low count rate can indicate two scenarios:
-we have a mismatch between the beam and the target (not much if any overlap)
-mabye the very low intersity of the beam (we cannot really monitor this, there are only estimates...)
Which tells us that we dont intersect with the target, that on the Xray spectras we dont see any peaks at 90 and 145 angles. There are two peaks in 35 angle, but they are maybe only from Pb conversion 75keV, etc... |
Sat Mar 21 11:30:04 2020, Laszlo, General, MWPC movement,
|
now we try to move the capture detector (MWPC in the 1. dipol before our Si setup) inside the ring while the DAQ was ON
we tried to move it as close as possible to the beam
On the picture below you can see that we had some increased current while moving the MWPC --> scattering from the beam while scraping it |
Sat Mar 21 11:32:46 2020, Ragan, Alex, Runs, run entry - run060,
|
Open file: runstart060
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 11:30 , first file: run060_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 11:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 4 Hz
Xray_90: 30 Hz
Xray_145: 21 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.04 uA
SIS particles before: 3.1e9
ESR particles at injection: estimated ~1.08e6
ESR particles after decel.:
Target ON density: 1.54e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 12:00:27 2020, Ragan, Alex, Runs, run entry - run060,
|
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 11:30 , first file: run060_0001.lmd
run stop at xx:xx , last file: run060_0xxx.lmd
_______________________________________________________________________________
time: 12:00 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 4 Hz
Xray_90: 28 Hz
Xray_145: 77 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.04 uA
SIS particles before: 3.1e9
ESR particles at injection: estimated ~1.08e6
ESR particles after decel.:
Target ON density: 1.74e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 12:02:57 2020, Ragan, Laszlo, General, run entry - run061,
|
12:02 pm - scapper is taken out completely
open file : runstart061 |
Sat Mar 21 12:06:50 2020, Laszlo, General, run61 - SCRAPER moved out,
|
we want to see any change on the Silicon count rate, because we will have now also Rutherford scattering. |
Sat Mar 21 12:30:30 2020, Ragan, Runs, run entry - run061,
|
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 12:00 , first file: run061_0001.lmd
run stop at xx:xx , last file: run0xx_0xxx.lmd
_______________________________________________________________________________
time: 12:30 am.
ON Rates
Si_X: 0 Hz
Si_Y: 0 Hz
Xray_35: 1 Hz
Xray_90: 23 Hz
Xray_145: 16 Hz
BaF_OR: Hz
Si voltage: 60.02 V
Si leakage current: 4.12 uA
SIS particles before: 2.5e9
ESR particles at injection: estimated ~1.03e6
ESR particles after decel.:
Target ON density: 1.76e13
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 21 12:32:00 2020, Laszlo, General, Estimated target thickness,
|
Target thickness must be like 5mm (was measured with a moving thin wire)
The beam thickness is small because of the low intensity
Maybe we hit the target a bit offset --> less rate?
We might have the option to increase the target 1magnitude more, but this might not help because we can kill the beam
with this.
I have the impression we just simply have less number of stored ions like 10^4 or evem less...
Yury: "we are unsure about the settings and desperately seek for any means of additional diagnostics" |
Sat Mar 21 12:42:21 2020, Ragan, General, Entry to ESR for MCP detector,
|
Pierre Michel and Laszlo go inside the ESR for switching on the MCP detector so that the photons from the gas jet and secondary beam interaction can be seen.
Close file: run061 |