Thu Mar 17 17:56:33 2022
Kristian
Calibration
HV dividers
PTB HV dividers arrived. Divider ratios are:
PT120: 12003,341
46
Thu Mar 31 22:41:35 2022
Kristian
Calibration
HV divider
We noticed a difference in the electron cooler
high voltage:
56
Fri Apr 1 18:19:58 2022
Kristian
Calibration
HV divider
We checked the strange behavior of the HV
dividers again. The Ohmlabs and the PTB divider
are in good agreement at 120 kV and 150 kV.
17
Wed Mar 16 12:04:40 2022
Kristian
Detectors
HV cable to particle detector South
Checked HV cable to particle detector south.
Label is HV2 Scraper.
100
Tue Apr 5 15:25:47 2022
Sebastian, Kristian, Pierre-Michel
DAQ
Go4 Conditions for "TDC_stacked_Sig/Ref" histogram
First version of TDC_stacked histograms implemented.
Under folder "Conditions" you can now integrate
88
Mon Apr 4 15:32:38 2022
Kristiand & Sebastian
DAQ
Go4 Backup Code
Due to some code changes (PMT over wavelength
historgram) Kristian and I backuped a working
Go4 code in the current go4 folder on the
79
Sun Apr 3 12:35:17 2022
Max
DAQ
Go 4 manual
How to start go4?:
- go to console
85
Mon Apr 4 00:19:16 2022
Ken Ueberholz
DAQ
FirstTests
New measurement:
Start: About 00:12
Stop: About 00:43
121
Thu Apr 7 02:32:29 2022
all on shift
Runs
First Scans 322-320nm
Laser scanning from 322-320 steps 0.01nm/s
DAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
169
Fri Apr 8 17:44:25 2022
Konstantin
Calibration
Final Timing
We measured the timing for the laser bunch
synchronization. A summary is given below.
201
Sun Apr 10 15:29:37 2022
Carsten,Sarper
Accelerator
Ecooler failed
Ecooler failed @15:23 Carsten is fixing it
Fixed @16:00
65
Sat Apr 2 15:54:32 2022
Carsten
Accelerator
ESR setup with primary beam and 1cm Be plate + Schottky data on NTCAP
MArkus and Bernd have setup the ESR with the
thick stripper foil and put the ion beam
(238U92+) on the central orbit.
112
Wed Apr 6 16:01:07 2022
BL
Accelerator
ESR settings before adjusting laser: 2022-04-06_14-37-30_ESR_EXP22_02_238U92_Brandau_30March22.C1.txt
# Version: 1.2
# Comment: ParamModi Export at 2022-04-06T14:37:35.957978+02:00[Europe/Berlin]
# Context: ESR_EXP22_02_238U92_Brandau_30March22.C1
107
Wed Apr 6 09:30:53 2022
Danyal
Accelerator
ESR is blue again - errors are fixed
The ESR is "blue" again.
The errors (scu related) have been fixed.
106
Wed Apr 6 08:31:54 2022
Danyal & Regina
General
ESR had some errors
Regina noticed that the ESR was "red"
This means that there are some errors.
50
Fri Apr 1 02:29:40 2022
Carsten
ESR Cooler crashed
ESR cooler crashed. We could not restart the
cooler. Since we had several other problems,
we stop now.
117
Wed Apr 6 22:29:55 2022
Patrick
Accelerator
ECooler voltages
ECooler voltages:
[B]06.04:[/B]
9
Fri Nov 5 17:23:23 2021
Rodolfo
DAQ
Dye trigger out
The dye laser offers different scan settings
(see pages 65 - 67 of the user manual). We
are using the following setting, see attached
14
Thu Mar 3 21:39:21 2022
Rodolfo
Laser
Dye solution, DCM in Ethanol and DMSO
I have prepared a new dye solution of DCM
in Ethanol and DMSO (1:1). The concentration
of the "oscillator + preamplifier" is 0,3
235
Fri Apr 15 20:43:18 2022
Konstantin
Laser
Dye changed
Dye of the laser system has been changed.
UV laser power increased from ~8 mJ to 11