Entry  Wed Jun 12 21:21:15 2024, Yuri, Detectors, NTCap started 
Fcenter - 244.6 MHz
BW - 10 MHz
Entry  Thu Jun 13 14:56:09 2024, Stefan Schippers, Accelerator, Estimated beam lifetime: About 150 s 
Estimate of storage lifetime using my code 'hydrocal':

 ion mass in u ...................................: 229
Entry  Wed May 29 10:54:21 2024, Shahab, Jan, General, Gas Target Events with new timing system 2024-05-29_11-07-40-259.pngIMG_0465.JPGIMG_0466.JPGIMG_0467.JPG
Using the new timing system, it is possible to grab any events as pulses, but also as long inter event gates under GENESYS. Many instances of GENESYS can
be running on ACO computers, so that there is no conflict, if an instance is running in main control room or another in ESR-Messhütte.
Entry  Fri Jun 7 17:10:45 2024, Sebastian, General, XUV LED 
Maximum XUV LED Voltage: 6.5V
Entry  Wed Jun 26 11:59:12 2024, Ruijiu, Shahab, Carsten, Analysis, Prepare plots for Thomas's presentation 6x
data:
(env_OnlineDataAnalysisSystem) litv-exp@lxbk0497:/lustre/astrum/experiment_data/2024-05_E018/OnlineDataAnalysisSystem/data/iq/IQ_2024-06-
12_21-47-54$
Entry  Thu Jun 13 18:48:26 2024, Ruijiu Chen, David, Shahab, Yuri, Analysis, The ion identification of 229Th is correct. simulation_result.outLifetime_of_beam7.pdf
Harmonic: 124.0 , Bp: 7.796046 [Tm]
ion            fre[Hz]                       yield [pps]    
------------------------------------------------------------
Entry  Thu Jun 13 12:37:14 2024, Ruijiu Chen, David, Analysis, Lifetime of beam in center of mass is 193 s. Lifetime_of_beam.pdf
 
Entry  Thu Jun 13 13:29:47 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 12 22:00- June 13 0:00 Lifetime_of_beam2.pdf
 
Entry  Thu Jun 13 14:20:36 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 13 4:30:7:00 Lifetime_of_beam3.pdf
 
Entry  Thu Jun 13 14:35:27 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 13 7:00~9:00 Lifetime_of_beam4.pdf
 
Entry  Thu Jun 13 14:41:22 2024, Ruijiu Chen, David, Analysis, Lifetime of beam during June 13 9:00~11:00 Lifetime_of_beam5.pdf
 
Entry  Fri May 31 15:53:06 2024, Ruijiu Chen, DAQ, run NTCAP system 
NTCAP is working again. 
Connect the RF cable and the scaler cables to NTCAP system.
The map of signal is recorded in following link. 
Entry  Mon Jun 10 11:59:12 2024, Ruijiu Chen, Analysis, The ion identification of spectrum recorded on 2022 simulation_result.outE142_TEline-ESR_229Th.lppThe_ion_identification_of_spectrum_recorded_on_2022_v2.pdf
The simulated frequency is given in simulation_result.out. The yield is calculated by LISE file. The LISE file is attached here also.
Entry  Wed Jun 12 01:51:51 2024, RuiJiu, David, Analysis, ID E142_TEline-ESR_229Th.lppsimulation_result.out229Th89_124h.png229Th89_125h.png
The preliminary identification has been thoroughly checked using the RionID software. We have confirmed that the identification is accurate.

Attached can be found the simulation file with each of the expected ions, their revolutions frequencies in the 125th harmonic and expected yield from the
Entry  Thu Jun 13 18:38:24 2024, Rodolfo Sanchez, Julian Palmes, Sebastian Klammes, Laser, Laser Dye change - new MRC settings - scraper checks of laser beam MRC-settings-13-06-2024-after-dye-change-at-3pm.JPG
We changed the dye at ~3pm.

After some fine adjustements of the laser we had to change the MRC settings, because the laser position changed.
Entry  Thu Apr 25 16:34:05 2024, Rodolfo, Laser, Efficiency of Fluorescein27 Fluorescein27_Efficiency.png
The figure below shows the efficiency of Fluorescein27 vs. Wavelength. Each point was averaged over 500 laser shots.

Dye Laser: Sirah, Cobra Strech. 
Entry  Wed May 29 09:49:30 2024, Rodolfo, Laser, Laser-beam profile Laserstrahl-at-EKühler_2024-05-03_#014.jpgLaserstrahl-at-EKühler_2024-05-03_Photo.jpg
Using a telescope (Plan-concave lens -500 mm and Plan-convex lens +1000 mm) after the pulsed-dye laser system we got the following laser-beam profile at
the Electron-Cooler's position. Dye Laser @ 550 nm / 275 nm  
Entry  Mon Jun 3 18:24:44 2024, Rodolfo, Detectors, PMT arrangement PMT_Arrangement_2024-06-03.jpgHV-Powersupply_PMTs_Thorium2024.jpg
The picture shows the actual configuration of the PMTs.

We are using a 4-Channel High-Voltage supply. The channels are labeled according to the PMTs names.
Entry  Mon Jun 3 19:42:06 2024, Rodolfo, Laser, Laser-beam through E-Cooler LaserBeam-at-Screen_ESR-NO_08-06-2024.JPG
UV-laser beam is now going through the Electron-Cooler. 

Telescope settings:
Entry  Tue Jun 4 22:54:02 2024, Rodolfo, Detectors, PMT - Manufacture - Test Result Data PMT_9423B_SN652_ETEnterprises_UniGießen.pdfPMT_9423B_SN653_ETEnterprises_TUDA.pdfPMT9422_SN1049_Datenblatt.pdf
 