Entry  Fri Jun 7 11:14:04 2024, Rodolfo, Laser, Trigger-signal for MRC MRC_TriggerSignal_T1_06-06-2024.jpgMRC_TriggerSignal_T2_Tmin_06-06-2024.jpgGeneratorSettings_for_MRC_06-06-2024.jpgMRC_Parameters_06-06-2024_18-30.JPG
We are using a 2-Channel Function Generator (from Textronik) to generate the trigger signal for the MRC Beam Stabilization. 

The triggers are (according to the MRC nomenclature):
Entry  Fri Jun 7 15:29:50 2024, Rodolfo, Detectors, Stored beam @ ESR Storedbeam@ESR_2024-06-07_15-25-18.png
One of the first PMT signals from the stored-ion beam @ ESR
Entry  Sat Jun 15 03:46:34 2024, Night shift, Accelerator, GSI down 
All quadrupole and dipole magnets at SIS and ESR are out of order. Repairs can be expected earliest tomorrow evening. No shifts will take place before 6pm.
Have a look at your mails for details.
Entry  Thu Jun 13 12:05:31 2024, Konstantin, Peter, Jonas, Accelerator, RF-amplitude Bunching80mA_BucketFill_10.pngBunching80mA_BucketFill_08.png
To realize the shortest bunches possible, we check the bunch length as a function of two different bunching amplitudes. With the bucket fill set to 1.0
we observe the spectra compiled in attachment 1. The second attachment is recorded with a bucket fill 0f 0.2.
Entry  Fri Jun 14 13:14:29 2024, Konstantin, Bernhard, Peter, Lukas, General, DAQ crashes at :10 
10 Minutes past a full hour (XX:10) the windows PCs (sometimes) loose connection.
This causes the labview server & the laser remote ctrl  to crash.
Entry  Wed Jun 12 12:12:44 2024, Konstantin Mohr, Julien Spahn, Jonas Koedel, Bernhard Maass, Accelerator, First Scraper Scan SpatialBeamOverlap.png
Thorium is in the ESR, we have time to check the beam position with the scrapers.
Beam Intensity in the ring 6E-5
Entry  Fri Jun 14 06:38:41 2024, Konstantin Mohr, Bernhard Maass, Peter Micke, Lukas Kau, Dounia Boudefla, Runs, Morning runs 
Very successful shift, no crashes until 11:10
Previous night shift had problems with the pulse laser starting around 3am.
Something was loose at the FCU. Rodolfo was called in and was able to fix it.
Entry  Thu Jun 6 07:12:49 2024, Konstantin Mohr, Laser, T-Scraper 6x
The T-Scrapers can be driven by DeviceControl, which must be started from a console. To do so, first open the app-launcher and then select "Device Control",
which is found under "Betrieb & Steuerung". Then select the appropriate context (should be the name of the experiment). After a short time the device icons
will be present. The scrapers can be found in the last four columns and the second last row (see screenshot 1). By default, they should be colored like
Entry  Thu Jun 6 09:23:53 2024, Konstantin Mohr, DAQ, Timing TimingSSH.pngDualTimer.jpegTimingAdjustment.JPG
The best way to adjust the bunch-laser timing is to start go4 (mbs must be running) from atppc023. Therefore use x2goclient and use the predefined session
to access LXG1297. Start go4 as usual ([URL=https://elog.gsi.de/esr/E0052/10]Entry 10[/URL] + [URL=https://elog.gsi.de/esr/E0052/11]Entry 11[/URL]). 
Entry  Thu Jun 13 10:32:29 2024, Konstantin, Accelerator, (Proper) Cooler settings 
We change the acceleration voltage of the electron cooler and observe the platform high voltage and the count rate at the particle detector south.
Cooler current at 100mA.
Entry  Tue Jun 11 09:17:46 2024, Julien, Konstantin, Lukas, DAQ, Important commands (DAQ1) SSH_Connection.pngMBS_Start.pngDAQ1_startup.pngRates.pngBildschirmfoto_2024-06-11_10-01-38.png
To connect to the DAQ1 pc, open a terminal and type:
 ssh atplaser@r4l-41
Enter password for user atplaser ([B]note that you're typing on an English keyboard[/B]).
Entry  Tue Jun 11 21:38:35 2024, Julian, Imke, Rodolfo, Laser, Wavemeter HeNe long time stability HeNe_LangeMessung_11-06-2024.JPG
The HeNe was running over night and the measured laser frequency of the wavemeter was logged, see picture.
A significant drift of around 300 MHz is visible during the night.
It is possible, that the laser lab got too cold during the night, as the pulsed laser was not running.
Entry  Tue Jun 11 21:23:11 2024, Julian, Imke, General, How to read out voltage medusa1.JPGmedusa3.pngmedusa4.png
1.) If not already opened, open the Medusa Laser Control software, see picture:
2.) In the "view" submenu, choose "proteus status".
3.) At the bottom of the list, the K250 shows the scaled voltage.
Entry  Wed Jun 12 17:12:13 2024, Julian, Danyal, Rodolfo, Laser, Timing für 229Th89+ Timing_229Th89_12-06-2024.JPG
We did the timing Ion-Beam Laser-beam time overlap. 

The ion revolution frequency (and therefore the bunching frequency) is: 1.5429 MHz.
Entry  Thu Jun 13 18:23:46 2024, Julian, Laser, Restarting the laser controller 
If the laser controller is locked up again, the little display will show an error message after an attempted medusa scan.
To restart it, follow these steps:
1.) Unlock the beam stabilization.
Entry  Tue Apr 16 14:42:37 2024, Jan, General, G-PAC Proposal G-22-00052.pdf
 
Entry  Mon May 27 13:37:31 2024, Jan, DAQ, MesyTec Shaper Control Screenshot2_MSCFGUI.pngScreenshot3_MSCFGUI.png
For the 2nd DAQ the MesyTec Shaper ([URL=https://elog.gsi.de/esr/NucAR+lab/230418_110112/MesyTec_MSCF16-F-V.pdf]MSCF manual[/URL]) is used as a spectroscopy
amplifier and CFD.
It is controlled via the MesyControlGUI, which is installed on SADPC055 with a USB->mesyBUS connection to the MSCF.
Entry  Thu Jun 13 22:08:07 2024, Dayshift, Accelerator, Problems with Accelerator? IMG_6064.jpgIMG_6065.jpgIMG_6066.jpg
It seems to be that there are some problems with the injections in the ESR.
The last 2 accumulation cycles showed that wheter only a small amount of ions are injected into the ESR or the injection is missing.
Entry  Tue Apr 16 16:28:21 2024, Danyal, General, Great 
Thanks Jan!
Entry  Thu Jun 6 07:54:15 2024, Danyal, General, pressure gauges and ion pumps  
yesterday (05.06.2024), firstly, the two ion pumps (underneath the fluorescence chamber) were switched off by the vacuum group (Björn Mai, Tel: 3438).
Secondly, the two pressure gauges (located near the target) were switched off.  The pressure gauge at the fluo chamber is called E02VM3x and the pressure
was 5.5e-11 mbar.  The other gauge is called IG2 and located further south, it measured 3.7e-11 mbar.  That was when ion pumps were still switched on.