ID |
Date |
Author |
Category |
Subject |
163
|
Mon Apr 6 05:28:55 2020 |
Ragan, Laszlo, Nikos | Runs | Zero hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 0 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 20:21, run0540.lmd
file running: 0555.lmd
_______________________________________________________________________________
time when accumulation starts: 04:51
time when storage starts: 05:28
time when storage ends: 05:28
I_cooler during storage time: -1 mA (20 mA)
I_cooler = 179 mA
I_SIS: 1.75e9
ESR particles after stacking: 2.2e6 (offset 5e5)
Number of stackings: 100
Target ON density: 4.45e12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 2mins
(i.e. time for which electron cooler is on after gas jet)
NTCAp file:
SC_2020-04-06_00-59-46
\IQ_2020-04-06_00-59-38
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement/ |
Attachment 1: 46C168E2-D1D5-4CD3-B87F-7F82D045D527.jpeg
|
|
Attachment 2: C55A1803-E814-412F-B3DC-40FE24946F8A.MOV
|
Attachment 3: 75662B09-68EE-49FD-9BB2-71766305ECF8.jpeg
|
|
Attachment 4: 1C0040AA-3CE4-4019-B85E-0049EBE85384.jpeg
|
|
Attachment 5: 2020-04-06_05-40-47-352.png
|
|
164
|
Mon Apr 6 05:43:50 2020 |
Ragan, Laszlo, Nikos | Runs | One and a half hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 1.5 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 20:21, run0540.lmd
file running: 0558.lmd
_______________________________________________________________________________
time when accumulation starts: 05:41
time when storage starts: 06:19
time when storage ends: 07:49
I_cooler during storage time: -1 mA (20 mA)
I_cooler = 179 mA
I_SIS: 1.75e9
ESR particles after stacking: 2.3e6 (offset 5e5)
Number of stackings: 100
Target ON density: 4.36e12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 3 mins
(i.e. time for which electron cooler is on after gas jet)
NTCAp file:
SC_2020-04-06_00-59-46
\IQ_2020-04-06_00-59-38
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement/ |
Attachment 1: 2020-04-06_06-18-59-809.png
|
|
Attachment 2: 946073FA-3077-4CBF-900B-565BD19CF040.jpeg
|
|
Attachment 3: 10FEB6AE-653B-4803-9927-EEB5BF33D3ED.jpeg
|
|
Attachment 4: 2020-04-06_08-03-40-493.png
|
|
116
|
Thu Apr 2 05:00:44 2020 |
Ragan, Esther, Oliver | Runs | Second measurement with 2 hrs storage time |
Electron cooler was off here. Thus, this measurement is not what we needed.
(in the picture below, it can be seen that the beam is not cooled)
beam: 205Tl81+ (no scraping)
energy: 400 MeV/u
storage time: 2 hrs
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): mm
run start at 01:48 , first file: run0287.lmd
file running: 0287.lmd
_______________________________________________________________________________
time when accumulation starts: 04:45
time when storage starts: 04:55
time when storage ends: 06:55
I_cooler during storage time: 10 mA
I_cooler = mA
I_SIS: 1.8e9
ESR particles after stacking: ~e5
Number of stackings: 20
Target ON density: 4e12
Target on time: 06:56:30
Target off time: 07:06:30
Target on time for measurement: 10 mins (by local mode)
NTCAp file:
SC_2020-04-01_16-36-43/0000xxx.iq.tdms
\IQ_2020-04-01_16-36-43/0000xxx.iq.tdms
IQ rate: 8 MS/s
(saved in drive : o)
copy and repeat the above (below the line) for every storage time measurement |
Attachment 1: 734CA93E-95FD-4C6E-8E90-8DCD961E4352.jpeg
|
|
118
|
Thu Apr 2 07:01:32 2020 |
Ragan, Esther, Oliver | Runs | Measurement with 4 hrs storage time |
beam: 205Tl81+ (no scraping)
energy: 400 MeV/u
storage time: 4 hrs
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): mm
run start at 01:48 , first file: run0287.lmd
file running: 0287.lmd
_______________________________________________________________________________
time when accumulation starts: 04:45
time when storage starts: 04:55
time when storage ends: 06:55
I_cooler during storage time: 10 mA
I_cooler = mA
I_SIS: 1.8e9
ESR particles after stacking: ~e5
Number of stackings: 20
Target ON density: 4e12
Target on time: 06:56:30
Target off time: 07:06:30
Target on time for measurement: 10 mins (by local mode)
NTCAp file:
SC_2020-04-01_16-36-43/0000xxx.iq.tdms
\IQ_2020-04-01_16-36-43/0000xxx.iq.tdms
IQ rate: 8 MS/s
(saved in drive : o)
copy and repeat the above (below the line) for every storage time measurement |
148
|
Sat Apr 4 17:32:01 2020 |
Ragan, Alex, Esther | General | No beam in ESR |
The beam is coming from SIS but doesn't arrive in ESR because the quadrupole magnets in ESR have failed.
Update (18:01): Problem has been resolved. |
149
|
Sat Apr 4 18:29:44 2020 |
Ragan, Alex, Esther | Runs | 0 hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 0 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 22:11, run0308.lmd
file running: 0339.lmd
_______________________________________________________________________________
time when accumulation starts: 17:56
time when storage starts: 18:28
time when storage ends: 18:28
I_cooler during storage time: -1 mA
I_cooler = 177 mA
I_SIS: 1.75e9
ESR particles after stacking: 1.4e6 (offset 3.5e5)
Number of stackings: ~65 (was set to 80 but stacking broke down after ~65)
Target ON density: 4.05e12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 2 mins
(i.e. time for which electron cooler is on after gas jet)
NTCAp file:
SC_2020-04-03_22-12-50
\IQ_2020-04-03_22-13-48
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement |
Attachment 1: 2020-04-04_18-27-53-442.png
|
|
Attachment 2: 2020-04-04_18-41-54-901.png
|
|
Attachment 3: F5D184AC-FB3E-4F9F-B839-F71BC55C0996.jpeg
|
|
Attachment 4: E4176CCB-1828-4E2E-85FB-0AC4BDC2808B.jpeg
|
|
150
|
Sat Apr 4 18:57:49 2020 |
Ragan, Alex, Esther | General | Timing problem with SIS & ESR and problems with stacking |
There are further problems with beam stacking in ESR. It works occasionally but keeps failing.
There is also timing problem between SIS and FRS. |
151
|
Sat Apr 4 19:55:37 2020 |
Ragan, Alex, Esther | Runs | Failed measurement...Ten hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
FAILED - measurement was stopped by sudden loss of the beam
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 10 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 19:02, run0343.lmd
file running: 0347.lmd
_______________________________________________________________________________
time when accumulation starts: 19:17
time when storage starts: 19:55
time when storage ends: 05:55
I_cooler during storage time: -1 mA
I_cooler = 177 mA
I_SIS: 1.8e9
ESR particles after stacking: 2.5e6 (offset 3e5)
Number of stackings: 100
Target ON density: xxe12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 5 mins
(i.e. time for which electron cooler is on after gas jet)
I_ESR (20:30) : 2.25e6
I_ESR (21:00) : 2.1e6
I_ESR (21:30) : 2.0e6
I_ESR (22:00) : 1.8e6
NTCAp file:
SC_2020-04-04_19-04-52
\IQ_2020-04-04_19-04-52
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement |
Attachment 1: 2020-04-04_19-54-47-760.png
|
|
Attachment 2: 2020-04-04_20-02-26-363.png
|
|
158
|
Sun Apr 5 15:28:35 2020 |
Ragan, Alex, Esther | Runs | Four hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 4 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 19:02, run0343.lmd
file running: 0539.lmd
_______________________________________________________________________________
time when accumulation starts: 15:27
time when storage starts: 16:05
time when storage ends: 20:05
I_cooler during storage time: -1 mA
I_cooler = -1 mA (20 mA)
I_SIS: 2e9
ESR particles after stacking: 2e6 (offset 5e5)
Number of stackings: 100
Target ON density: 3.92e12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 5 mins
(i.e. time for which electron cooler is on after gas jet)
I_ESR (16:30) : 1.9e6
I_ESR (17:00) : 1.75e6
I_ESR (17:30) : 1.6e6
I_ESR (18:00) : 1.55e6
I_ESR (18:30) : 1.45e6
I_ESR (19:00) : 1.3e6
I_ESR (19:30) : 1.25e6
I_ESR (20:00) : 1.2e6
NTCAp file:
SC_2020-04-04_19-04-52
\IQ_2020-04-04_19-04-52
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement/ |
Attachment 1: 2020-04-05_15-27-32-971.png
|
|
Attachment 2: A2DFA8C1-D623-42FA-BBD5-1F75F51D51DD.jpeg
|
|
Attachment 3: 2020-04-05_16-23-38-007.png
|
|
Attachment 4: B17A216F-15D8-48F2-9403-37C8236A38C0.jpeg
|
|
Attachment 5: 87D9890E-AC6D-4E3F-B45B-FED6A301253B.jpeg
|
|
Attachment 6: 2020-04-05_20-16-54-054.png
|
|
Attachment 7: 43239EE6-100B-4540-894C-B98E659BE472.jpeg
|
|
159
|
Sun Apr 5 20:23:02 2020 |
Ragan, Alex, Esther | Runs | Half-hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 0.5 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 20:21, run0540.lmd
file running: 0540.lmd
_______________________________________________________________________________
time when accumulation starts: 20:21
time when storage starts: 20:59
time when storage ends: 21:29
I_cooler during storage time: -1 mA
I_cooler = 179 mA (20 mA)
I_SIS: 2e9
ESR particles after stacking: 2.2e6 (offset 2.5e5)
Number of stackings: 100
Target ON density: 4.14e12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 5 mins
(i.e. time for which electron cooler is on after gas jet)
NTCAp file:
SC_2020-04-04_19-04-52
\IQ_2020-04-04_19-04-52
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement/ |
Attachment 1: 2B066703-2B92-4FBD-94F0-01C50424A7DB.MOV
|
Attachment 2: 2020-04-05_21-00-05-018.png
|
|
Attachment 3: 57175364-4FA3-4C56-8DC0-D4E1FE3BFFA9.jpeg
|
|
Attachment 4: 523688CD-02EB-4A57-ADFC-77122CD205F5.MOV
|
Attachment 5: E55589A9-3C71-4CF6-ACAB-63FD23B00BE3.jpeg
|
|
Attachment 6: 2020-04-05_21-42-32-717.png
|
|
Attachment 7: 39A3C392-8E7D-44A3-8564-29AC89A4CC7C.jpeg
|
|
160
|
Sun Apr 5 21:50:02 2020 |
Ragan, Alex, Esther | Runs | Half-hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 0.5 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 20:21, run0540.lmd
file running: 0546.lmd
_______________________________________________________________________________
time when accumulation starts: 21:43
time when storage starts: 22:21
time when storage ends: 22:51
I_cooler during storage time: -1 mA
I_cooler = 179 mA (20 mA)
I_SIS: 1.75e9
ESR particles after stacking: 2.2e6 (offset 3e5)
Number of stackings: ~90 (was set to 100 but ~10 were missed)
Target ON density: 4.2e12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 3 mins
(i.e. time for which electron cooler is on after gas jet)
NTCAp file:
SC_2020-04-04_19-04-52
\IQ_2020-04-04_19-04-52
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement/ |
Attachment 1: 2020-04-05_22-21-44-967.png
|
|
Attachment 2: 8F69C30E-2A79-405C-85D2-CFA061720E14.jpeg
|
|
Attachment 3: 922E0C48-BC5F-4B8B-B35F-F7E2E823CFB2.MOV
|
Attachment 4: 76898BAD-3A48-4E8F-A830-BA0F158C9DB8.MOV
|
Attachment 5: AEB662B9-D22B-4213-9D4F-1F723404DF2C.jpeg
|
|
Attachment 6: B601FDD9-8CA7-4DD0-A17B-678C44EDBDD9.jpeg
|
|
Attachment 7: 2020-04-05_23-04-35-616.png
|
|
161
|
Sun Apr 5 23:28:01 2020 |
Ragan, Alex, Esther | Runs | One-hour measurement (S2: 0/35 mm and S6: -20/7 mm) |
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 1 hr
S2: 0/35 mm
s6: -20/7
purpose: data with TARGET ON
Detector position (CsISiPHOS): out of the ring
Detector position (MWPC): -60 mm
run start at 20:21, run0540.lmd
file running: 0549.lmd
_______________________________________________________________________________
time when accumulation starts: 23:04
time when storage starts: 23:42
time when storage ends: 00:42
I_cooler during storage time: -2 mA (20 mA)
I_cooler = 180 mA
I_SIS: 1.8e9
ESR particles after stacking: 2.2e6 (offset 3e5)
Number of stackings: 100
Target ON density: 4.24e12
Target on time for measurement: 10 mins (by event mode)
time spend at manipulation 13 : 3 mins
(i.e. time for which electron cooler is on after gas jet)
NTCAp file:
SC_2020-04-04_19-04-52
\IQ_2020-04-04_19-04-52
IQ rate: 8 MS/s
(saved in drive : O)
copy and repeat the above (below the line) for every storage time measurement/ |
Attachment 1: 2020-04-05_23-42-50-224.png
|
|
Attachment 2: 2020-04-06_00-56-01-052.png
|
|
Attachment 3: 0A9DA63C-7DBD-42B3-9CE9-08E9785B33B2.jpeg
|
|
Attachment 4: C885A387-78BB-49BF-AD5C-D7FEAB8248DE.jpeg
|
|
Attachment 5: 7487031D-7B12-4ACF-B0C8-55D5B928C0CE.jpeg
|
|
Attachment 6: 3EE56236-447E-4EAE-8394-B1F05BC9D1C7.jpeg
|
|
Attachment 7: D809F5FB-214D-486B-A4F0-912FD2C0CB94.MOV
|
18
|
Thu Mar 26 17:21:40 2020 |
Ragan | General | Stochastic cooling |
1) From SIS, 206Pb67+ @401.17 MeV/u goes to FRS where only SEETRAM is placed in the target area to strip off 206Pb67+ to get 206Pb81+.
2) There is 206Pb81+ (H-like primary beam) inside ESR at 400 MeV/u.
3) The ESR team is now trying Stochastic cooling with 206Pb81+ beam at 400 MeV/u. |
19
|
Fri Mar 27 13:02:07 2020 |
Ragan | General | Stochastic cooling |
1) ESR team is successful with the Stochstic cooling of primary H-like 206Pb81+ beam @400 MeV/u.
2) Now, they are trying for stacking of the beam. |
Attachment 1: stochastic_cooling.PNG
|
|
20
|
Fri Mar 27 13:04:17 2020 |
Ragan | General | FRS Settings until now |
Yuri and Helmut have been extensively involved in tuning and optimizing of the FRS.
26th March, 2020 (Evening setting):
1) 206Pb67+ beam from SIS @401.17 MeV/u.
2) SEETRAM in target area of FRS is used for stripping the beam from SIS to get 206Pb81+ and is then transported to ESR @400 MeV/u. (SEETRAM consists of three Ti foils of ~10 um thickness which are used for stripping purpose (more info: https://www-win.gsi.de/frs-setup/ ))
3) SL1 slits are opened +-10 mm to get rid of other charge states of 206Pb and only transport 206Pb81+ through FRS.
27th March, 2020 (Evening setting):
1) Different target (Be 1-6 g/cm2 with Nb backing) and degrader (Al)thicknesses are used for the optimization of 206Pb81+ with matter in FRS to get the beam with @400 MeV/u in ESR.
2) 206Pb67+ beam from SIS @540-560 MeV/u. |
Attachment 1: frs.pdf
|
|
Attachment 2: FRS.pdf
|
|
21
|
Fri Mar 27 13:40:54 2020 |
Ragan | General | NTCap start and shutdown information |
The attachment contains information on how to start and shutdown NTCap and bridge computer. |
Attachment 1: ntcapmanual.pdf
|
|
22
|
Fri Mar 27 19:51:37 2020 |
Ragan | General | ESR Machine |
By changing the tune to Qx=2.33, Qy=2.36 the momentum acceptance was significantly improved. A variation of the cooler voltage of 10300 V was possible without beam loss. That corresponds to a momentum acceptance of 2.7 %. That should provide good conditions for longitudinal stacking.
Thanks to the ESR team ! |
23
|
Fri Mar 27 19:59:09 2020 |
Ragan | General | Beam stacking in ESR is achieved |
Thanks to Sergey and Markus, stacking of primary H-like 206Pb81+ beam in ESR is achieved.
The stacking of the primary beam was established. There is continuous cooling on the injection orbit by stochastic cooling and by electron cooling on the stack orbit. (Time controlled operation of stochastic cooling could not be achieved due to controls issues). After stchastic cooling on the injection orbit the rf system decelerates the beam by 1.5 % in momentum and at the lower momentum electron cooling keeps the beam. The DC trafo shows accumulation of 10 injections of primary low intensity Pb81+ beam. Losses during the accumulation seems to be small. |
Attachment 1: 8B7F254E-DB10-48B6-9E2E-9CA0FF998C12.MOV
|
Attachment 2: stacking.png
|
|
24
|
Fri Mar 27 20:05:43 2020 |
Ragan | General | H2 gas jet ready |
Thanks to Nikos, stable H2 gas jet target with 10^14 particles/cm^3 is ready.
(More information can be found on: https://ulpc24.gsi.de/cgi-bin/jet.py?gasart=Helium ) |
Attachment 1: BAFA7906-5F66-4108-86F9-6D61573B43CD.MOV
|
25
|
Fri Mar 27 20:52:31 2020 |
Ragan | General | Plans for the measurement with 206Pb81+ |
We plan to measure:
1. Lifetime of H-like 206Pb81+ beam with two electron cooler currents:
a) 200 mA
b) 10 mA (so that recombination rate is less)
using MWPC (capture detector in outer pocket) and CsISiPHOS (loss detector in inner pocket).
2. To find the efficiency of the MWPC. |