HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  proton-capture on 118Te, Page 10 of 29  Not logged in ELOG logo
ID Date Authorup Category Subject Year Text Attachments
  336   Thu May 13 21:22:31 2021 Jan GloriusCalibrationrun0039 - Xray145 calib Pb210 d=305mm2021Efficiency calibration in the lab

************************************
  
  337   Fri May 14 09:06:55 2021 Jan GloriusCalibrationrun0040 - Xray145 calib Ba133_hi d=305mm2021Efficiency calibration in the lab

************************************
  
  338   Fri May 14 09:35:13 2021 Jan GloriusCalibrationrun0041 - Xray145 calib Cd109 d=305mm2021Efficiency calibration in the lab

************************************
  
  339   Fri May 14 10:28:49 2021 Jan GloriusCalibrationrun0042 - Xray145 calib 241Am_hi d=305mm2021Efficiency calibration in the lab

************************************
  
  340   Fri May 14 11:17:48 2021 Jan GloriusCalibrationrun0043 - Xray145 calib 210Pb d=305mm2021Efficiency calibration in the lab

************************************
  
  341   Fri May 14 13:58:52 2021 Jan GloriusCalibrationrun0044 - Xray145 calib 210Pb d=305mm2021Efficiency calibration in the lab

************************************
  
  342   Sat May 15 20:21:59 2021 Jan GloriusCalibrationrun0045 - Si pulser run2021Detector: DSSD
Source: CAEN Detector Emulator
  
  343   Sun May 16 11:25:25 2021 Jan GloriusCalibrationrun0046 - Xray E-calib 241Am all dets2021Detectors: Xray1 (GEM1800), Xray2 (GLP), Xray3
(GEM3000)
Sources: different Am241 at each detector
  
  344   Sun May 16 11:54:12 2021 Jan GloriusCalibrationXray performance in lab2021These are the current Xray detector performances
in the lab using data from run0046
  
  345   Sun May 16 12:55:48 2021 Jan GloriusDAQevent server lxg1299:60032021new event server is set up at lxg1299 on port
6003
It runs as:
  
  347   Tue May 18 01:03:59 2021 Jan GloriusCalibrationrun0048 - calib all Xray det.2021Efficiency calibration in ESR

************************************
  
  348   Tue May 18 01:21:27 2021 Jan GloriusCalibrationrun0047 - crap2021    
  349   Tue May 18 11:22:57 2021 Jan GloriusCalibrationrun0049 - calib all Xray det.2021Efficiency calibration in ESR

************************************
  
  351   Wed May 19 13:47:26 2021 Jan GloriusGeneralGasTarget Operation2021We have two tasks to take over for the target
operation:
 IMG_20210519_133923186_HDR.jpgIMG_20210519_133629322_HDR.jpg 
  563   Sun May 30 10:24:20 2021 Jan GloriusCalibrationrun0212 - X-calib. 90-pb 145-am2021Efficiency calibration in ESR after experiment

************************************
  
  564   Sun May 30 11:32:06 2021 Jan GloriusCalibrationrun0213 - X-calib. 90-am 145-pb 35-ba2021Efficiency calibration in ESR after experiment

************************************
  
  565   Sun May 30 13:23:26 2021 Jan GloriusCalibrationrun0214 - X-calib. 90-ba 145-ba 35-am2021Efficiency calibration in ESR after experiment

************************************
  
  566   Sun May 30 14:38:09 2021 Jan GloriusCalibrationrun0216 - X-calib. 90-ba 35-pb2021Efficiency calibration in ESR after experiment

************************************
  
  574   Thu Jun 24 09:43:01 2021 Jan GloriusDAQUnpacker2021The unpacker used for the production runs
of E127b is located at 
/u/litv-exp/unpacker/unpackexps/e127_TO_2021_with_ECL
  
  498   Thu May 27 14:33:05 2021 Jan, Beatriz, AlexRunsRun 0154 - crap run2021No. of stacks: 10 
length SC10: 2x 5.5s 
bump ge01sq2f (sc10): -20 mm 
  
ELOG V3.1.5-fc6679b