  proton-capture on 118Te, Page 16 of 29  Not logged in ELOG logo
ID Date Author Category Subjectup Year Text Attachments
  21   Thu Aug 29 10:02:22 2019 JanDetectorsbakeout at ESR setup The bakeout for our detector setup has started
on the evening of 27.08.2019 
We have a temperature sensor in the vacuum
 T_set_bakeout.png 
  357   Thu May 20 17:31:50 2021 Jan, Laszlo, BeatrizGeneralbeam & target alignement2021beam and target alignement was checked by
looking at the Xray rates. Best case when:
Target bump (position) SC 9: -18.5mm
  
  576   Thu Jul 8 14:07:19 2021 JanCalibrationbeam energies2021Table of ion energies calculated from cooler
parameters
 CodeCogsEqn.pngCodeCogsEqn(1).png 
  272   Mon Apr 6 23:00:51 2020 LaszloCalibrationbeam energies for 124Xe and 118Te measurements "The e- cooler settings were the same for
the 124Xe and 118Te beams" - Sergey --> speed
of the ions is the same --> same MeV/u
 SP54120040623030.pdf 
  40   Wed Mar 11 14:33:44 2020 LaszloGeneralbeam time manual Here you can find the digital version of the
E127 beam time manual.
 E127_experimental_manual.pdfmanual.odt 
  31   Thu Jan 23 16:35:47 2020 LaszloDAQcable documentation    cable_documentation_e127.pdfcable_documentation_e127.ods 
  34   Fri Feb 21 09:39:40 2020 LaszloDAQcable documentation    cable_documentation_e127.pdfcable_documentation_e127.ods 
  293   Thu Apr 29 20:32:52 2021 Jan GloriusCalibrationcalibration sources2021We use the following list of sources for calibration
of the Xray detectors:
  
  543   Sat May 29 13:43:39 2021 Tino, Rene, Yuri, Laszlo, MarkusRunschange of settings2021from now on, everal beam setting will be different.
We could not get the beam back to were it
was before. When the scraper was pulled back
  
  149   Sat Mar 21 22:57:28 2020 Laszlo, JanDAQchanging cables of the Xray 90 and 145 Energy signals of 90 and 145 degree detector
have been checked and exchanged
They were connected to the wrong ADC channel.
  
  577   Wed Jul 14 14:46:05 2021 Jan, SophiaDetectorscollimator geometry2021We have measured the collimator geometry.
The annotations of the variables can be found
in the attached sketch  
 10x 
  388   Sat May 22 16:29:07 2021 Laszlo et al.Generalcoolers are back2021we can measure again.

(please write a detailed description if needed)
  
  60   Tue Mar 17 08:15:49 2020 JanGeneralcurrent grids & screen in TE  measured beam diagnosis with 124Xe48+ at 326
MeV/u
 2020-03-16_18-51-50-170.pngIMG_0694.jpg 
  36   Fri Feb 21 11:29:59 2020 JanDetectorsdet. distances at target chamber This is the lookup table for the distance
of each x-ray detector to the target.
See attched foto for explanation.
 Photonen_Kammer.png 
  97   Sat Mar 21 02:36:44 2020 LaszloGeneraldetector and scraper position For the 124Xe primary beam measurement:
-with the DSSSD we scraped the beam at position
-40
 IMG_20200321_025644.jpg 
  191   Sun Mar 22 14:58:59 2020 LaszloGeneraldropping density of Gasjet after like 20min run, the density of the gasjet
already dropped from 10^14 to 8.7*10^13.
Now it seems to remain in that value
 ga_jet_drop.png 
  278   Wed Apr 29 16:06:28 2020 LaszloCalibrationefficiency fit - 90degree, combined dataset For the efficiency vs E fit of the 90degree
Xray detector I have used the following phenomenological
funciton:
 efficiency_90degree-1an2datasets_phen_lin.pngefficiency_90degree-1an2datasets_phen_lin_bigRange.png 
  279   Thu Apr 30 17:40:57 2020 LaszloCalibrationefficiency fits For all 3 detector the calibration data sets
were combined to include the systematics
in the fit results directly. Combining means
 90degree_efficiency.zip145degree_efficiency.zip35degree_efficiency.zip 
  281   Wed May 6 23:02:42 2020 LaszloCalibrationefficiency values I have calculated the efficiency values by
putting the energies of the K-REC peaks into
the phenomenological (empirical) function
 90degree_efficiency_combined.png90degree_efficiency_combined.ps 
  317   Thu May 6 13:39:02 2021 Jan GloriusCalibrationefficiency xray 35deg2021the attached efficiency curve for the 35 deg.
xray detector is made with the runs
e127b_run0015.lmd
 35deg_eff.png35deg_eff.dat 