ID |
Date |
Author |
Category |
Subject |
Text |
 |
1
|
Fri Apr 25 15:45:39 2025 |
Jan Glorius | DAQ | DR DAQ - MBS & Go4 | The DR DAQ is located in AP Messhuette, here
is the basic info.
|
|
Draft
|
Wed Apr 30 19:59:18 2025 |
Carsten | DAQ | DR_DAQ | enum{TRIG_INJECTION=1,
TRIG_NEWRAMP=2,
TRIG_NEWVOLTAGE=3,
|
|
3
|
Mon May 5 11:29:28 2025 |
Rodolfo, Simon, Nils, Volker | Detectors | PMTs | These are the PMTs installed at the optical
detection region:
|
   |
4
|
Mon May 5 16:26:07 2025 |
Carsten | DAQ | DR Computer Names and IPs | Computers used for control of HV amplifiers
and DR microcontrollers are
[LIST]
|
|
5
|
Mon May 5 21:13:29 2025 |
Rodolfo | Laser | Collimation of laser beam | Here some parameters for the collimation of
the laser beam
|
|
6
|
Tue May 6 15:35:12 2025 |
Rodolfo, Konstantin | Laser | MRC Settings | Following settings (P-Factor, Directions and
Bandwidth) are used for the laser beam stabilization.
Full energy (ca. 150 mJ @ 593 nm).
|
  |
7
|
Wed May 7 14:02:58 2025 |
Konstantin | DAQ | DAQ Folder | The folder of the data acquisition are:
[B]Go4[/B] (atplaser@lxg1297):[B] ~/go4/drals[/B]
|
|
8
|
Wed May 7 17:29:19 2025 |
Rodolfo, Simon | DAQ | Fast Photodiodes | Signal for the fast photodiodes. The laser
beam
[LIST]
|
|
9
|
Wed May 7 20:31:52 2025 |
Carsten | DAQ | DRALS cabling (DR part) | [B] Green Corner, patch panel to ESR[/B]
All signals from/ to ESR TTL 5V.
Signals are GND decoupled with grey boxes! |
|
10
|
Thu May 8 10:11:37 2025 |
Carsten | General | Schottky spectrum ( 2 Harmonics) from the earlier 209Bi80+ Libelle run (thesis C. Trageser) | |
|
11
|
Thu May 8 10:21:10 2025 |
Carsten | | Link to thesis of C. Trageser NTCAP/ Automated Schottky analysis of cooler voltage and space charge) | The thesis of Christian might be helpful w.r.t.
to energy calibration as it shows how to
link Schottky frequency to ion energy (might |
|
12
|
Thu May 8 13:33:13 2025 |
Rodolfo, Simon | Laser | Camera @ South-West Screen | Network camera to monitor the position of
the laser beam after the electron cooler.
|
|
13
|
Thu May 8 17:23:51 2025 |
Shahab | General | Schottky TV | setup Schottky TV:
connect to atppc030 using:
|
|
14
|
Thu May 8 19:35:18 2025 |
Simon | | PMT count rates | I tested the PMTs and tried to reduce the
background signal as far as possible.
|
|
15
|
Thu May 8 22:50:37 2025 |
Carsten | DAQ | Preliminary Timing Settings | Tentatively:
[B]DAC:[/B]
|
|
16
|
Thu May 8 23:36:19 2025 |
Konstantin | DAQ | Fileserver | To save files, the rfio-server must be started
on lxg1297 in the folder /data.local2/BiDrals/.
The file structure is
|
|
17
|
Fri May 9 00:56:07 2025 |
Konstantin | DAQ | First Files | Files 91 + 92 were recorded with the Trigger
logic as explained in [URL=https://elog.gsi.de/esr/E0038/15][COLOR=blue][B]ID
15[/B][/COLOR][/URL]. The laser was scanned |
|
18
|
Fri May 9 14:21:18 2025 |
Rodolfo | Accelerator | T-Scrapers | Information about the T-Scrapers at the ESR
Electron Cooler. The width of the scraper
is approx. 9 mm.
|
|
19
|
Fri May 9 17:47:07 2025 |
Konstantin | DAQ | HV Divider | The HV voltage applied at the high-voltage
platform of the electron cooler can be observed
at [URL=https://lxyrpc01.gsi.de/grafana/d/bec8zc1424agwc/esr-electron-cooler-voltages?orgId=1&from=now-5m&to=now&refresh=5s]HV-divider[/URL]. |
|
20
|
Fri May 9 18:34:08 2025 |
Konstantin | DAQ | Important diagnoses of analysis parameters | The filling of some histograms in the go4
analysis framework is controlled by the SetParameters.C
and SetConditions.C files.
|
    |