HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018 E0052_2025
  LIBELLE 2025, Page 1 of 5  Not logged in ELOG logo
ID Date Author Category Subject Text Attachments
  1   Fri Apr 25 15:45:39 2025 Jan GloriusDAQDR DAQ - MBS & Go4The DR DAQ is located in AP Messhuette, here
is the basic info.
  
  Draft   Wed Apr 30 19:59:18 2025 CarstenDAQDR_DAQ       enum{TRIG_INJECTION=1, 
    TRIG_NEWRAMP=2, 
    TRIG_NEWVOLTAGE=3, 
  
  3   Mon May 5 11:29:28 2025 Rodolfo, Simon, Nils, VolkerDetectorsPMTsThese are the PMTs installed at the optical
detection region:
 SolarBlind_ET_9422_SN1042.pdfThornEmi_PMT9422A_SN1001_(1987).pdfPMT_Arrangement_Libelle2025.jpgPMT_R1017_Configuration_Beamtime2025.png 
  4   Mon May 5 16:26:07 2025 CarstenDAQDR Computer Names and IPsComputers used for control of HV amplifiers
and DR microcontrollers are
[LIST]
  
  5   Mon May 5 21:13:29 2025 RodolfoLaserCollimation of laser beamHere some parameters for the collimation of
the laser beam
 Cobra593nm_Laserbeam_Collimation_2025-05-05.JPG 
  6   Tue May 6 15:35:12 2025 Rodolfo, KonstantinLaserMRC SettingsFollowing settings (P-Factor, Directions and
Bandwidth) are used for the laser beam stabilization.
Full energy (ca. 150 mJ @ 593 nm).
 MRC_Settings_Cobra593_VolleLeistung_2025-05-06.JPGMRC_Controller_Settings_2025-05-06.jpgAFG3202C_Settings.jpg 
  7   Wed May 7 14:02:58 2025 KonstantinDAQDAQ FolderThe folder of the data acquisition are:

[B]Go4[/B] (atplaser@lxg1297):[B] ~/go4/drals[/B]
  
  8   Wed May 7 17:29:19 2025 Rodolfo, SimonDAQFast PhotodiodesSignal for the fast photodiodes. The laser
beam
[LIST]
 FastPD-Signals_Messhütte_2025-05-07.jpg 
  9   Wed May 7 20:31:52 2025 CarstenDAQDRALS cabling (DR part)[B] Green Corner, patch panel to ESR[/B]
All signals from/ to ESR TTL 5V.
Signals are GND decoupled with grey boxes!
  
  10   Thu May 8 10:11:37 2025 CarstenGeneralSchottky spectrum ( 2 Harmonics) from the earlier 209Bi80+ Libelle run (thesis C. Trageser)   Schottky_Libelle_on_209Bi80.png 
  11   Thu May 8 10:21:10 2025 Carsten Link to thesis of C. Trageser NTCAP/ Automated Schottky analysis of cooler voltage and space charge)The thesis of Christian might be helpful w.r.t.
to energy calibration as it shows how to
link Schottky frequency to ion energy (might
  
  12   Thu May 8 13:33:13 2025 Rodolfo, SimonLaserCamera @ South-West ScreenNetwork camera to monitor the position of
the laser beam after the electron cooler.
 
 Laserbeam@SW-Screen_2025-05-08.JPG 
  13   Thu May 8 17:23:51 2025 ShahabGeneralSchottky TVsetup Schottky TV:

connect to atppc030 using:
  
  14   Thu May 8 19:35:18 2025 Simon PMT count ratesI tested the PMTs and tried to reduce the
background signal as far as possible.
  
  15   Thu May 8 22:50:37 2025 CarstenDAQPreliminary Timing SettingsTentatively:

[B]DAC:[/B]
  
  16   Thu May 8 23:36:19 2025 KonstantinDAQFileserverTo save files, the rfio-server must be started
on lxg1297 in the folder /data.local2/BiDrals/.
The file structure is
 MBS_SshowAcq.png 
  17   Fri May 9 00:56:07 2025 KonstantinDAQFirst Files Files 91 + 92 were recorded with the Trigger
logic as explained in [URL=https://elog.gsi.de/esr/E0038/15][COLOR=blue][B]ID
15[/B][/COLOR][/URL]. The laser was scanned
  
  18   Fri May 9 14:21:18 2025 RodolfoAcceleratorT-ScrapersInformation about the T-Scrapers at the ESR
Electron Cooler. The width of the scraper
is approx. 9 mm.
 Scrapereinstellung_am_ESR.pdf 
  19   Fri May 9 17:47:07 2025 KonstantinDAQHV Divider The HV voltage applied at the high-voltage
platform of the electron cooler can be observed
at [URL=https://lxyrpc01.gsi.de/grafana/d/bec8zc1424agwc/esr-electron-cooler-voltages?orgId=1&from=now-5m&to=now&refresh=5s]HV-divider[/URL].
  
  20   Fri May 9 18:34:08 2025 KonstantinDAQImportant diagnoses of analysis parametersThe filling of some histograms in the go4
analysis framework is controlled by the SetParameters.C
and SetConditions.C files.
 QSwitchDiagnose.pngSetConditions.pngMHzScaler.pngMHZWinC.pngSetParameters.png 
ELOG V3.1.5-fc6679b