HOME
ESR
EXPERIMENTS
LABS etc
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
Bound beta decay experiment on Tl-205, Page 3 of 9
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Category --
Analysis
Calibration
DAQ
General
Collaboration
Runs
Detectors
SlowControl
180 Entries
Goto page
Previous
1
,
2
, 3,
4
...
7
,
8
,
9
Next
All
ID
Date
Author
Category
Subject
Text
35
Sat Mar 28 13:19:56 2020
Ragan
Runs
Template
beam:
energy:
storage time:
48
Sun Mar 29 11:12:00 2020
Ragan
Runs
start run e121_run_0239.lmd
Sergey and Yuri are tuning Tl beam. The particle
number in ers is about 1e4. I(SIS)=5e8
57
Sun Mar 29 20:32:20 2020
Ragan
General
Template for Pb halflive measurement
beam:
energy:
59
Sun Mar 29 21:34:46 2020
Ragan
Runs
First run
beam: 206Pb81+
energy: 400 MeV/u
61
Sun Mar 29 21:55:47 2020
Ragan
General
MWPC
Alex goes to Messhute to check the signals
from MPWC. After he completes, we start with
the measurements with the primary beam )
63
Mon Mar 30 00:32:32 2020
Ragan
Runs
First measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u
64
Mon Mar 30 01:01:53 2020
Ragan
Runs
First measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u
65
Mon Mar 30 01:07:29 2020
Ragan
General
Problem with SIS runstop: 0256
There is problem with SIS
Run stop: 0257.lmd (at1:06)
66
Mon Mar 30 01:25:57 2020
Ragan
Runs
First measurement with 206Pb81+ beam
01:17 Problem with SIS is solved
01:19 run start 0258.lmd
67
Mon Mar 30 01:43:58 2020
Ragan
General
First measurement with 206Pb81+ beam pattern details
The following shows the pattern for first
measurement in ESR (gas jet is on for = 60*5
secs = 300 secs as it can be seen on step
68
Mon Mar 30 02:00:46 2020
Ragan
Runs
First measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u
69
Mon Mar 30 02:27:44 2020
Ragan
Runs
Second measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA
beam: 206Pb81+
74
Mon Mar 30 04:15:29 2020
Ragan
General
Second measurement with 206Pb81+ beam at I_cooler = 200 mA
In the picture below, a very nice storage
of 206Pb81+ at 200 mA electron cooler current
for no gas jet target can be seen in ESR.
76
Mon Mar 30 06:15:13 2020
Ragan
Runs
Second measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA
beam: 206Pb81+
78
Mon Mar 30 06:30:52 2020
Ragan
Runs
Second measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA
beam: 206Pb81+
79
Mon Mar 30 06:34:47 2020
Ragan
General
Second measurement with 206Pb81+ beam at I_cooler = 20 mA
In the ESR picture below, the decay of beam
is very fast initially for few minutes and
then the decay is constant. But why does
103
Mon Mar 30 20:51:06 2020
Ragan
Detectors
Bias Voltage for Si-pads
The limit of the leakage current for all Si
pads was increased from 1500 nA to 5000nA
and
107
Tue Mar 31 20:32:05 2020
Ragan
General
203Tl80+ 200Hg79+ 205Tl81+
Below in the schottky spectrum, on left is
203Tl80+ contamination, in middel is 200Hg79+
contamination and on right most is 205Tl81+.
108
Tue Mar 31 20:50:05 2020
Ragan
General
200Hg79+ 205Tl81+
203Tl80+ impurity is removed by moving scrapper
inside ESR.
Only 220Hg79+ is left now
109
Tue Mar 31 21:07:05 2020
Ragan
General
Separation of 203Tl80+ and 200Hg79+ using scrapper in ESR
It can be seen in the video how 203Tl80+ (on
extreme left) and then 200Hg79+ (in middle
originally) is separted from 205Tl81+ by
Goto page
Previous
1
,
2
, 3,
4
...
7
,
8
,
9
Next
All
ELOG V3.1.5-fc6679b