HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  Bound beta decay experiment on Tl-205, Page 3 of 9  Not logged in ELOG logo
ID Date Authorup Category Subject
  35   Sat Mar 28 13:19:56 2020 RaganRunsTemplate
beam: 
energy: 
storage time:

purpose: data with TARGET ON

Detector position (CsISiPHOS):  mm
Detector position (MWPC):       mm

run start at xx:xx , first file: run0xxx.lmd
run stop  at xx:xx , last file:  run0xxx.lmd

_______________________________________________________________________________

time: 

I_cooler =  mA



HV1
CH1 voltage:           60V  
CH1 leakage current:   uA

CH2 voltage:           60V  
CH2 leakage current:   uA

CH3 voltage:           60V  
CH3 leakage current:   uA

CH4 voltage:           60V  
CH4 leakage current:   uA

HV2
CH1 voltage:           60V  
CH1 leakage current:   uA

CH2 voltage:           60V  
CH2 leakage current:   uA

CH3 voltage:           -50V  
CH3 leakage current:   uA

CH4 voltage:           -160V  
CH4 leakage current:   uA


SIS particles before:           
ESR particles after stacking:     
Number of stackings:
Target ON density:   
Target on time for measurement:           


NTCAp file:
IQ_2020-03-27_21-02-31/0000xxx.iq.tdms
SC_2020-03-27_21-02-31/0000xxx.iq.tdms

copy and repeat the above (below the line) every 30 minutes
  48   Sun Mar 29 11:12:00 2020 RaganRunsstart run e121_run_0239.lmd
Sergey and Yuri are tuning Tl beam. The particle number in ers is about 1e4. I(SIS)=5e8

some events on MWPC can be seen !
  57   Sun Mar 29 20:32:20 2020 RaganGeneralTemplate for Pb halflive measurement
beam: 
energy: 

purpose: data with electron cooler current xx mA

Detector position (CsISiPHOS):  mm
Detector position (MWPC):       mm

run start at xx:xx , first file: run0xxx.lmd
run stop  at xx:xx , last file:  run0xxx.lmd

_______________________________________________________________________________

time: 

I_cooler =  mA



HV1
CH1 voltage:           V  
CH1 leakage current:   uA

CH2 voltage:           V  
CH2 leakage current:   uA

CH3 voltage:           V  
CH3 leakage current:   uA

CH4 voltage:           V  
CH4 leakage current:   uA

HV2
CH1 voltage:           V  
CH1 leakage current:   uA

CH2 voltage:           V  
CH2 leakage current:   uA

CH3 voltage:           V  
CH3 leakage current:   uA

CH4 voltage:           V  
CH4 leakage current:   uA


SIS particles before:           
ESR particles at injection:     
ESR particles after stacking:     
Target ON density:              


NTCAp file:
IQ_2020-03-27_21-02-31/0000xxx.iq.tdms
SC_2020-03-27_21-02-31/0000xxx.iq.tdms

copy and repeat the above (below the line) every 30 minutes
  59   Sun Mar 29 21:34:46 2020 RaganRunsFirst run
beam: 206Pb81+
energy: 400 MeV/u

purpose: data with primary beam for detector efficiency and cross-section calculations

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 21:25 , run file: run0250.lmd
run stop  at 21:31 , close file:  run0250.lmd

_______________________________________________________________________________

time: 21:25

I_cooler = 177 mA

SIS particles before:  2E8        
ESR particles when gas jet is on:  3.6E6
Target ON density:  4.34E12        


NTCAp file:
SC_2020-03-29_21-27-57
IQ_2020-03-29_21-27-57

copy and repeat the above (below the line) every 30 minutes
  61   Sun Mar 29 21:55:47 2020 RaganGeneralMWPC
Alex goes to Messhute to check the signals from MPWC. After he completes, we start with the measurements with the primary beam )
Attachment 1: Comparison.png
Comparison.png
  63   Mon Mar 30 00:32:32 2020 RaganRunsFirst measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u

purpose: data with primary beam for detector efficiency and cross-section calculations

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 00:28 , run file: run0252.lmd
run stop  at xx:xx , close file:  run0.lmd

_______________________________________________________________________________

time: 00:28

I_cooler = 176 mA

SIS particles before:  3E8        
ESR particles when gas jet is on:  2.4E6
Target ON density:  4.45E12        
Target on time : 5 minutes

NTCAp file:
SC_2020-03-30_00_28_45
IQ_2020-03-30_00_28_45
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  64   Mon Mar 30 01:01:53 2020 RaganRunsFirst measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u

purpose: data with primary beam for detector efficiency and cross-section calculations

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 00:28 , run file: run0252.lmd
file currently running: run0257.lmd

_______________________________________________________________________________

time: 01:00

I_cooler = 176 mA

SIS particles before:  3.3E8        
ESR particles when gas jet is on:  2.4E6
Target ON density:  4.49E12        
Target on time : 5 minutes

NTCAp file:
SC_2020-03-30_00_28_45 (run ongoing)
IQ_2020-03-30_00_28_45 (run ongoing)
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  65   Mon Mar 30 01:07:29 2020 RaganGeneralProblem with SIS runstop: 0256
There is problem with SIS
Run stop: 0257.lmd (at1:06)
  66   Mon Mar 30 01:25:57 2020 RaganRunsFirst measurement with 206Pb81+ beam
01:17 Problem with SIS is solved
01:19 run start 0258.lmd


beam: 206Pb81+
energy: 400 MeV/u

purpose: data with primary beam for detector efficiency and cross-section calculations

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 01:19 , run file: run0258.lmd
file currently running: 

_______________________________________________________________________________

time: 01:19

I_cooler = 176 mA

SIS particles before:  1.5E8        
ESR particles when gas jet is on:  2.8E6
Target ON density:  4.49E12        
Target on time : 5 minutes

NTCAp file:
SC_2020-03-30_01-18-31
IQ_2020-03-30_00_22-52
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  67   Mon Mar 30 01:43:58 2020 RaganGeneralFirst measurement with 206Pb81+ beam pattern details
The following shows the pattern for first measurement in ESR (gas jet is on for = 60*5 secs = 300 secs as it can be seen on step SC7 in pattern).
One injection cycle runs for ~ 6 mins.
Attachment 1: 90FC7D41-6C97-4760-B5A3-3CF60643A405.jpeg
90FC7D41-6C97-4760-B5A3-3CF60643A405.jpeg
Attachment 2: BF20DBD8-1672-4817-8412-13B29CBF2E0A.jpeg
BF20DBD8-1672-4817-8412-13B29CBF2E0A.jpeg
  68   Mon Mar 30 02:00:46 2020 RaganRunsFirst measurement with 206Pb81+ beam
beam: 206Pb81+
energy: 400 MeV/u

purpose: data with primary beam for detector efficiency and cross-section calculations

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 01:19 , run file: run0258.lmd
run stop at 02:05: stop file: 0265.lmd

_______________________________________________________________________________

time: 02:05

I_cooler = 176 mA

SIS particles before:  3.3E8        
ESR particles when gas jet is on:  4E6
Target ON density:  4.53E12        
Target on time : 5 minutes

NTCAp file:
SC_2020-03-30_01-18-31
IQ_2020-03-30_00_22-52
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  69   Mon Mar 30 02:27:44 2020 RaganRunsSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 02:24 , run file: run0267.lmd  (0266.lmd is garbage file)
run stop at :

_______________________________________________________________________________

time: 02:24

I_cooler = 176 mA

SIS particles before:  2.5E8        
ESR particles:  4.9E6
        


NTCAp file:
SC_2020-03-30_02-27-10
IQ_2020-03-30_02-27-10
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  74   Mon Mar 30 04:15:29 2020 RaganGeneralSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
In the picture below, a very nice storage of 206Pb81+ at 200 mA electron cooler current for no gas jet target can be seen in ESR. The measurement started at 02:24 and we will now finish it in 5-10 mins. We will now do two more measurements for I_cooler = 10 mA ans 20 mA.
Attachment 1: 1A7AE154-6A88-4AED-BA5D-748025FCD226.jpeg
1A7AE154-6A88-4AED-BA5D-748025FCD226.jpeg
  76   Mon Mar 30 06:15:13 2020 RaganRunsSecond measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 06:08 , run file: run0270.lmd  (0268.lmd and 0269.lmd are garbage files)
run stop at :

_______________________________________________________________________________

time: 06:08

I_cooler = -1 mA

SIS particles before:  2.5E8        
ESR particles:  3.01E6
        


NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  78   Mon Mar 30 06:30:52 2020 RaganRunsSecond measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 06:08 , run file: run0270.lmd  (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd

_______________________________________________________________________________

time: 06:30

I_cooler = -1 mA

      
ESR particles:  2.6E5
        


NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  79   Mon Mar 30 06:34:47 2020 RaganGeneral Second measurement with 206Pb81+ beam at I_cooler = 20 mA
In the ESR picture below, the decay of beam is very fast initially for few minutes and then the decay is constant. But why does it decay for first few minutes ?
Attachment 1: C7A2736D-9C0A-4531-A768-85A55943EB5A.jpeg
C7A2736D-9C0A-4531-A768-85A55943EB5A.jpeg
  103   Mon Mar 30 20:51:06 2020 RaganDetectorsBias Voltage for Si-pads
The limit of the leakage current for all Si pads was increased from 1500 nA to 5000nA and 
leakage current was recorded for different Bias Voltages (32V, 35V, 40V, 45V, 50V, 55V 
and 60V).
Since, I_leakage remains < 3 uA for 60 V, it is decided to increase the Bias Voltage for 
all the Si-pads from 32 V to 60 V.
For DSSD and CsI, bias voltages remains same (-50V and -160V respectively).
Attachment 1: Si_pad_bias-voltage.ods
  107   Tue Mar 31 20:32:05 2020 RaganGeneral203Tl80+ 200Hg79+ 205Tl81+
Below in the schottky spectrum, on left is 203Tl80+ contamination, in middel is 200Hg79+ contamination and on right most is 205Tl81+.
These contaminations cannot be seen on CsISiPHOS but can only be seen on schottky.
The goal now is to get rid of these contaminations by putting slits.
Attachment 1: 85AD7203-736C-4531-BA80-D045CC690BED.jpeg
85AD7203-736C-4531-BA80-D045CC690BED.jpeg
  108   Tue Mar 31 20:50:05 2020 RaganGeneral200Hg79+ 205Tl81+
203Tl80+ impurity is removed by moving scrapper inside ESR.
Only 220Hg79+ is left now
Attachment 1: 31E7D028-F469-4BFF-B683-203821C174E9.jpeg
31E7D028-F469-4BFF-B683-203821C174E9.jpeg
  109   Tue Mar 31 21:07:05 2020 RaganGeneralSeparation of 203Tl80+ and 200Hg79+ using scrapper in ESR
It can be seen in the video how 203Tl80+ (on extreme left) and then 200Hg79+ (in middle originally) is separted from 205Tl81+ by using scrapper in ESR.
Now, we want 205Pb81+ mixed with 205Tl81+ to be separated as much as possible in FRS.
Attachment 1: 06B012F5-5435-41D7-AD82-4A5FDADF281E.MOV
ELOG V3.1.5-fc6679b