Thu May 20 17:31:50 2021, Jan, Laszlo, Beatriz, General, beam & target alignement, 2021
|
beam and target alignement was checked by looking at the Xray rates. Best case when:
Target bump (position) SC 9: -18.5mm
|
Thu May 20 17:31:28 2021, Beatriz, Laszlo, Calibration, run0051, 2021
|
crap |
Thu May 20 15:15:54 2021, Beatriz, Laszlo, Calibration, run0050, 2021
|
crap |
Wed May 19 19:47:14 2021, Yuri, General, Beam Halflife at 30 AMeV, 2021
|
|
Wed May 19 15:09:22 2021, Helmut Weick, General, FRS settings, LISE file, 2021
|
Here is a setting plan for FRS and corresponding LISE files.
2 LISE files still use the old FRS-ESR optics, one the new with S6 focus on slits.
But this does not make a big difference for the simulation, only dispersion S2-S6 is lower.
|
Wed May 19 13:47:26 2021, Jan Glorius, General, GasTarget Operation, 2021
|
We have two tasks to take over for the target operation:
1. We have to refill the blue LN2 bottle on the roof of ESR every morning (see 1st attached foto)
|
Tue May 18 21:08:16 2021, ESR team, General, Beam stacking, 2021
|
Beam stacking. 3 pulses, stochastically cooled and stacked on an inner orbit |
Tue May 18 11:22:57 2021, Jan Glorius, Calibration, run0049 - calib all Xray det., 2021
|
Efficiency calibration in ESR
************************************
|
Tue May 18 01:21:27 2021, Jan Glorius, Calibration, run0047 - crap, 2021
|
|
Tue May 18 01:03:59 2021, Jan Glorius, Calibration, run0048 - calib all Xray det., 2021
|
Efficiency calibration in ESR
************************************
|
Sun May 16 13:31:49 2021, Laszlo, DAQ, Cabling Documentation, 2021
|
Si HV and current was switched in the last documentation. |
Sun May 16 12:55:48 2021, Jan Glorius, DAQ, event server lxg1299:6003, 2021
|
new event server is set up at lxg1299 on port 6003
It runs as:
/data.local1/gstore/mrevserv64 lxg1275 |
Sun May 16 11:54:12 2021, Jan Glorius, Calibration, Xray performance in lab, 2021
|
These are the current Xray detector performances in the lab using data from run0046
[TABLE border="1"]
|
Sun May 16 11:25:25 2021, Jan Glorius, Calibration, run0046 - Xray E-calib 241Am all dets, 2021
|
Detectors: Xray1 (GEM1800), Xray2 (GLP), Xray3 (GEM3000)
Sources: different Am241 at each detector
|
Sat May 15 20:21:59 2021, Jan Glorius, Calibration, run0045 - Si pulser run, 2021
|
Detector: DSSD
Source: CAEN Detector Emulator
|
Fri May 14 13:58:52 2021, Jan Glorius, Calibration, run0044 - Xray145 calib 210Pb d=305mm, 2021
|
Efficiency calibration in the lab
************************************
|
Fri May 14 11:17:48 2021, Jan Glorius, Calibration, run0043 - Xray145 calib 210Pb d=305mm, 2021
|
Efficiency calibration in the lab
************************************
|
Fri May 14 10:28:49 2021, Jan Glorius, Calibration, run0042 - Xray145 calib 241Am_hi d=305mm, 2021
|
Efficiency calibration in the lab
************************************
|
Fri May 14 09:35:13 2021, Jan Glorius, Calibration, run0041 - Xray145 calib Cd109 d=305mm, 2021
|
Efficiency calibration in the lab
************************************
|
Fri May 14 09:06:55 2021, Jan Glorius, Calibration, run0040 - Xray145 calib Ba133_hi d=305mm, 2021
|
Efficiency calibration in the lab
************************************
|