Entry  Fri May 14 11:17:48 2021, Jan Glorius, Calibration, run0043 - Xray145 calib 210Pb d=305mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Fri May 14 13:58:52 2021, Jan Glorius, Calibration, run0044 - Xray145 calib 210Pb d=305mm, 2021 
Efficiency calibration in the lab

************************************
Entry  Sat May 15 20:21:59 2021, Jan Glorius, Calibration, run0045 - Si pulser run, 2021 
Detector: DSSD
Source: CAEN Detector Emulator
Entry  Sun May 16 11:25:25 2021, Jan Glorius, Calibration, run0046 - Xray E-calib 241Am all dets, 2021 
Detectors: Xray1 (GEM1800), Xray2 (GLP), Xray3 (GEM3000)
Sources: different Am241 at each detector
Entry  Sun May 16 11:54:12 2021, Jan Glorius, Calibration, Xray performance in lab, 2021 
These are the current Xray detector performances in the lab using data from run0046

[TABLE border="1"]
Entry  Sun May 16 12:55:48 2021, Jan Glorius, DAQ, event server lxg1299:6003, 2021 
new event server is set up at lxg1299 on port 6003
It runs as:
/data.local1/gstore/mrevserv64 lxg1275
Entry  Tue May 18 01:03:59 2021, Jan Glorius, Calibration, run0048 - calib all Xray det., 2021 
Efficiency calibration in ESR

************************************
Entry  Tue May 18 01:21:27 2021, Jan Glorius, Calibration, run0047 - crap, 2021 
 
Entry  Tue May 18 11:22:57 2021, Jan Glorius, Calibration, run0049 - calib all Xray det., 2021 
Efficiency calibration in ESR

************************************
Entry  Wed May 19 13:47:26 2021, Jan Glorius, General, GasTarget Operation, 2021 IMG_20210519_133923186_HDR.jpgIMG_20210519_133629322_HDR.jpg
We have two tasks to take over for the target operation:

1. We have to refill the blue LN2 bottle on the roof of ESR every morning (see 1st attached foto)
Entry  Sun May 30 10:24:20 2021, Jan Glorius, Calibration, run0212 - X-calib. 90-pb 145-am, 2021 
Efficiency calibration in ESR after experiment

************************************
Entry  Sun May 30 11:32:06 2021, Jan Glorius, Calibration, run0213 - X-calib. 90-am 145-pb 35-ba, 2021 
Efficiency calibration in ESR after experiment

************************************
Entry  Sun May 30 13:23:26 2021, Jan Glorius, Calibration, run0214 - X-calib. 90-ba 145-ba 35-am, 2021 
Efficiency calibration in ESR after experiment

************************************
Entry  Sun May 30 14:38:09 2021, Jan Glorius, Calibration, run0216 - X-calib. 90-ba 35-pb, 2021 
Efficiency calibration in ESR after experiment

************************************
Entry  Thu Jun 24 09:43:01 2021, Jan Glorius, DAQ, Unpacker, 2021 
The unpacker used for the production runs of E127b is located at 
/u/litv-exp/unpacker/unpackexps/e127_TO_2021_with_ECL
Entry  Thu Jan 17 08:45:43 2019, Jan, Detectors, Micron W1 DSSSD - technical information,  6x
Attached are the spec sheets and design drawings of the new DSSSDs from Micron.
Additionally, the 3D model made by Laszlo is also attached as stp and dwg.
Entry  Fri Apr 5 05:46:20 2019, Jan, DAQ, running DRASI for (p,g),  
We now have a drasi DAQ running for our (p,g) experiments.
The RIO we have it installed right now is: r4l-58
It shall be used with the user <litv-exp>
Entry  Fri Apr 5 06:05:55 2019, Jan, DAQ, making changes to the DAQ ,  
If you need to add or change a module of the VME crate you need to follow this proceedure:

1. stop DRASI
Entry  Wed Jun 5 11:29:13 2019, Jan, Detectors, position/channel calib.,  
This is the first position calibration done with the detector installed in the holder. The goal is to assign rough positions (top/bottom/left/right) to
PreAmp- and Shaper-channels.
Entry  Fri Jun 7 10:18:23 2019, Jan, Runs, prerun001 - MixedAlpha,  alpha_centered.jpg
save point: lxg1275:/datalocal1/e127/predata/prerun001-root

~2h run