HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  nuclear two-photon decay, all entries  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sat Jul 3 08:12:22 2021, Dima, Yuri, General, Beam stop 
We stopped the beam at 08:10

The latest recorded tdms files:
Entry  Sat Jul 3 06:48:38 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Closer potential isomer tracks 70Se_close_pot_isomers.png
After looking through >800 shots from Jul 2nd 21h to Jul 3rd 05h, we couldn't find a single example of a "smoking gun" isomer decay. I.e. I'm talking about
the examples Liliana posted earlier. We did find many examples (roughly 10%) where the ion track spontaneously 
disappeared, but this shouldn't be the isomer as there was no frequency shift.
    Reply  Sat Jul 3 07:35:31 2021, The remote Canadian eager beaver (Iris), Analysis, Closer potential isomer tracks 410MHz-2021.07.02.21.42.36.139.tiq.png410MHz-2021.07.02.22.40.24.894.tiq.png
Here's a list of the spectra to look at for the potential isomer, taken btw 21:00 on July 2nd and 6:30 on July 3rd. Two examples attached.

Name Comment
Entry  Sat Jul 3 06:55:57 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000761
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003720
Entry  Sat Jul 3 06:49:55 2021, The remote Canadian eager beavers (Guy &Iris), Analysis, List of possible spectra with isomer decay 410MHz-2021.07.02.22.03.37.550.tiq.png
Attached is an example for the possible isomer (on the left) next to the 70Se (right). 

Here's the list with the files to look at, btw 21:00-6:30. Further analysis needs to be done offline. The slight frequency shift overnight made it a bit
Entry  Sat Jul 3 04:58:34 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000735
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003589
Entry  Sat Jul 3 04:33:50 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Slight shift in 70Se frequency 70Se-shift-21h-4h.png
Looks like the beam is slightly drifting...the 70Se peak frequency is slightly shifted to the left, by ~0.5 kHz compared to earlier spectra. Might be a
problem with the analyzer (?) or the storage ring energy (slightly lower?)... nothing drastical but to be observed.
Entry  Sat Jul 3 03:41:48 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Summed Spectra Summary 72Ge_sum.png72Br_sum.png70Se_not-scraped.png70Se_strong-scraped.png70Se_not-scraped_high_contrast.png
To summarise the method of bulk summing the spectra, I've created frequency vs time spectra by using the e143_analyser.py script to stack a series of -s
slices. I applied it to some of last runs data with 72Ge, to the 72Br data, last night's less-scraped 70Se, and tonight's more-scraped 70Se, respectively.
Entry  Sat Jul 3 03:07:43 2021, The remote Canadian eager beavers (Guy & Iris), Analysis, Some single spectra (410 MHz) from 21-24h July2-70Se-single-spectra-21-24h.pdf
Attached are some single spectra with a rough attempt to group them according to the different ions that appear.
Entry  Sat Jul 3 02:56:04 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000707
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003452
Entry  Sat Jul 3 01:28:08 2021, The remote Canadian eager beavers (Guy and Iris), Analysis, Summed spectra 410 MHz from 21:00-23:59 (70Se) July2-21-0h-410MHz_AllSpectra_70Se.png
Here's a picture with all injections with an ion in the spectrum (empty ones were removed- list below). The time slices are 0-0.5-1-1.5-2s, then in 0.2s
steps up to 3s. Not really anything to see :-(  The previous shift was right, looking at single spectra might be more useful. I'll group the pictures and
upload some "interesting" ones.
Entry  Sat Jul 3 00:59:01 2021, Dima, David, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000680
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003322
Entry  Fri Jul 2 23:09:22 2021, Dima, David, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000655
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003199
Entry  Fri Jul 2 21:07:31 2021, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000627
 p:\E143\iq\IQ_2021-06-30_23-27-34\0003062
Entry  Fri Jul 2 20:33:44 2021, Yuri, Accelerator, 70Se setting with closed scrapers 
We tune back to 70Se.
The scrapers stay closed at EEXDS2HA=0 mm, EEXDS1HG=+5 mm
"Single"-particle run
Entry  Fri Jul 2 20:01:16 2021, Liliana, Runs, Some plots from the Br setting 6x
 
Entry  Fri Jul 2 19:57:12 2021, Shahab, Yuri, Wolfram, Liliana, Runs, stop DAQ  
At 19:56 the DAQ is stopped. 
The plan is to go back to the setting for Se. 
Last files for the Br setting:
Entry  Fri Jul 2 19:06:18 2021, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000600
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002931
Entry  Fri Jul 2 17:31:04 2021, Liliana, General, status 
at 17:20 intensity was suddenly reduced. 
Operators checked. Intensity was a bit low and fluctuating for a while (8e8 to 1e9)
Intensity (1.5e9) was recovered at 18:16
Entry  Fri Jul 2 17:27:56 2021, Liliana, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000577
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002818
Entry  Fri Jul 2 16:14:17 2021, Yuri, Accelerator, Scrapers 4 72Br 1C28A49A-5FA1-4A81-8675-3ED9660FD793.png
Starting 15:15
The scrapers are moved very much close to each other to eliminate all background particles and leaving basically single ions injected for 72Br. Do not
wonder, this means that also many empty files are created.
Entry  Fri Jul 2 15:03:37 2021, Pavlos, Alexandre, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000543
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002655
Entry  Fri Jul 2 14:18:04 2021, Pavlos, Alexandre, Runs, Change of the measurment to 72Br 
Both resonators will now be retuned to look for the isomeric state in 72Br.

Last files for 70Se are:
Entry  Fri Jul 2 13:44:50 2021, Sergey, et al, Accelerator, El cooler 
Up to now, attempts to cool the fat line between Se and Ar were conducted. We give up it now and remove cooling
Entry  Fri Jul 2 13:37:00 2021, Pavlos, Alexandre, DAQ, Change of the measurement time from 10s to 20s 
Last files with the measurement time of 10s for the two resonators are:

245MHz-2021.07.02.13.36.00.674.tiq
Entry  Fri Jul 2 13:10:00 2021, Yuri, Accelerator, Scrapers 
12:46 moved the TOF detector scraper back to -11 mm
Entry  Fri Jul 2 12:59:21 2021, Pavlos, Alexandre, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000515
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002516
Entry  Fri Jul 2 12:42:54 2021, Gregor, Analysis, Spectra 6:00-12:00 12x
0.1s time slices for 245MHz and 410MHz, with e143_analyzer.py script

python $AnalyzerPath -s 0.$start -t 0.$time sparc-daq-02.gsi.de/E143-245MHz/245MHz-2021.07.02.$hour.* -o t_0.$start-0.$stop
Entry  Fri Jul 2 12:18:35 2021, Pavlos, Alexandre, Accelerator, e-cooling 
Sergey Litvinov will now try to setup the e-cooler to cool the beam in the ESR. 
The data taking has been stopped (except the NTCAP).
Entry  Fri Jul 2 11:44:25 2021, Helmut, Yuri, Accelerator, move scrapers to see effect on unknown lines 
We close the arc inside and straight section inside scrapers to narrow and cut the 70Se line.
Then look what the other lines left of 70Se will do.
Entry  Fri Jul 2 10:47:56 2021, Pavlos, Alexandre, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000485
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002370
Entry  Fri Jul 2 08:54:12 2021, Pavlos, Alexandre, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000459
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002242
Entry  Fri Jul 2 07:31:44 2021, The remote Canadian eager beavers (Iris and Guy), Analysis, 00h to 05h Summed Spectra 245MHz-07.02.00-05h-sum_10ms.png245MHz-07.02.00-05h-sum_10ms_zoom.png410MHz-07.02.00-05h-sum_10ms.png410MHz-07.02.00-05h-sum_10ms_zoom.png
Using the scripts I posted previously, I summed 5.5 hours of data from midnight to 5:30 July 2nd CEST. 
I used 10ms time steps for better time resolution, but that did leave questionable frequency resolution. If anyone would like to see higher resolved frequency
plots for the 
Entry  Fri Jul 2 01:34:03 2021, The remote Canadian beavers (Iris, Guy), Analysis, Summary of spectra 22:00-23:00 July1-22-23h-410MHz_Spectra_0.1s_steps.pngJuly1-22-23h-410MHz_Spectra_0.02s_steps_start_1s.pngSum_410MHz_May10-1-2am_5_0-5_175s.png
The last hour before the gas bottle change is summarized here. 
The first pic shows the 410 MHz spectra taken from 22-23h on the 410 MHz analyzer, in time slices of 0.1 sec from 0s-2s.
The second pic shows the spectra in 20ms slices from 1s-1.16s.
    Reply  Fri Jul 2 02:03:36 2021, The remote Canadian beavers (Iris, Guy), Analysis, Summary of spectra 0:00-1:00 July2-0-1h-410MHz_Spectra_0.02s_steps_start_1s.png
Same as before, for 0-1h on July 2nd

       Reply  Fri Jul 2 04:27:38 2021, The remote Canadian beavers (Iris and Guy), Analysis, Summary of spectra 0:00-4:00 (410 MHz) July2-0-4h-410MHz_Spectra_0.02s_steps_start_1s.png
Same as before for 0-4h on July 2nd.

> Same as before, for 0-1h on July 2nd
          Reply  Fri Jul 2 06:33:48 2021, The remote Canadian beavers (Iris and Guy), Analysis, Summary of spectra 4:00-6:00 (410 MHz) July2-4-6h-410MHz_Spectra_0.02s_steps_start_1s.png
Same as before for 4-5h and 5-6h.
No isomer, I think :-( (Sorry, Wolfram!)
             Reply  Fri Jul 2 06:52:11 2021, The remote Canadian eager beavers (Iris and Guy), Analysis, Summary of spectra 0:00-6:00 (410 MHz) July2-4-0-6h-410MHz_AllSpectra_0.025s_steps_start_1.04s.png
Same as before but for 0-6h, 25ms time slices starting at 1.04s.

> Same as before for 4-5h and 5-6h.
Entry  Fri Jul 2 06:51:45 2021, Pavlos, Kanika, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000431
 p:\E143\iq\IQ_2021-06-30_23-27-34\0002106
Entry  Fri Jul 2 05:08:16 2021, Guy Leckenby (Canadian beaver team), Analysis, e143_analyser.py Summing Script e143_sum_ana.bashe143_comparison.C410MHz-07.01.22h-sum_20ms.png
I've written two scripts that others might find useful for the on-line analysis. 
  1. The first is a simple bash script that runs a for loop to run the e143_analyzer.py script for a sequence of start values (-s). You'll need to change
the increment and 
Entry  Fri Jul 2 04:58:39 2021, IK, Kanika, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000405
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001978
Entry  Fri Jul 2 03:19:49 2021, IK, KK, Runs, drop of intensity 

And the intensity is back again to 5E9 at 03:20
Entry  Fri Jul 2 03:10:03 2021, IK, KK, Runs, drop of intensity 
We see that intensity stabalized at 9E8 which is smaller then before. 
We neticed this at 2:50, keep observing.
Entry  Fri Jul 2 01:43:56 2021, IK, KK, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000360
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001759
Entry  Fri Jul 2 01:39:51 2021, IK, KK, Runs, drop of intensity 

We see a drop in beam intensity from 7E9 to 2E8 between 01:30 and 01:43
Entry  Fri Jul 2 01:31:35 2021, The remote Canadian beavers (Iris, Guy), Analysis, First spectra after bottle change 410MHz-2021.07.01.23.38.25.809.tiq.png410MHz-2021.07.01.23.38.08.817.tiq.png
The first good spectra after the gas bottle change is from 23:38:25 (on the 410 MHz Analyzer) 
Entry  Fri Jul 2 00:08:22 2021, IK, Kanika, DAQ, NTCAP status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000338
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001651
Entry  Thu Jul 1 23:46:17 2021, Iris, General, Less beam after gas bottle change? Comparison-21h-2340h.png
Looks like there is a bit less beam now in the ring. I just looked at one spectra from before the gas bottle change and after...
    Reply  Thu Jul 1 23:54:43 2021, Iris, General, Less beam after gas bottle change? Comparison-21h-2350h.png
No, everything okay! Must have had a very good earlier run to compare.

> Looks like there is a bit less beam now in the ring. I just looked at one spectra from before the gas bottle change and after...
Entry  Thu Jul 1 23:38:55 2021, IK, KK, Runs, Change of gas bottle 
The gas bottle has been changed and the beam is back.
Entry  Thu Jul 1 23:07:47 2021, IK, KK, Runs, source 

The change of the source happens now
Entry  Thu Jul 1 21:35:32 2021, Shahab, Runs, some pics after 15dB amplification on 410 asd.png821.png
 
Entry  Thu Jul 1 21:35:15 2021, Shahab, DAQ, increase factor 4 in power for 410  
increase factor 4 in power for 410 

Entry  Thu Jul 1 21:15:01 2021, Andrew Nic, DAQ, NTCAP Status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000299
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001462
Entry  Thu Jul 1 20:48:58 2021, Shahab Andrew Nic, DAQ, Acquisition started 
15dB amplifier on 410MHz 
Entry  Thu Jul 1 20:35:21 2021, Andrew Nic Shahab, DAQ, Acquisition stopped  
Checking if signal can be further amplified 

Last files:
Entry  Thu Jul 1 19:34:11 2021, Shahab, DAQ, increase factor 4 in power for 410  410MHz-2021.07.01.19.23.49.099.tiq.png410MHz-2021.07.01.18.48.07.516.tiq.png
increase factor 4 in power for 410 

Entry  Thu Jul 1 19:24:59 2021, Nic Andrew Shahab, Runs, Start of data taking again 
410 MHz resolution and power optimised

Entry  Thu Jul 1 18:56:49 2021, Shahab, Runs, Short interruption in recording  
DAQs and NTCAP
Entry  Thu Jul 1 18:54:44 2021, Andrew, Nic, General, NTCap Status 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000267
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001305
Entry  Thu Jul 1 18:49:59 2021, Shahab, Runs, possible isomer? possible_isomer.png
 
Entry  Thu Jul 1 18:07:10 2021, Shahab, Runs, settings of the analyzers after changing the trigger position asd.jpgasd2.jpg
 
Entry  Thu Jul 1 18:01:52 2021, Andrew Nic Shahab, DAQ, Change triggers to 10% 
Change the triggers to 10%. Last files with 50/50:
410MhZ 2021-.07.01.17.56.12.936
245MhZ 2021.07.01.18.02.16.938 
Entry  Thu Jul 1 16:47:15 2021, Andrew Nic, Runs, Frequency shift 
The freqency suddenly shifted at time 16:11:47 and remained shifted until now 

The ESR status in the monitor stayed blue. No obvious sign that a magnet was down. The operators are checking
    Reply  Thu Jul 1 17:01:43 2021, Jacobus, Runs, Frequency shift 245MHz-2021.07.01.16.12.03.686.tiq.png
> The freqency suddenly shifted at time 16:11:47 and remained shifted until now 

> The ESR status in the monitor stayed blue. No obvious sign that a magnet was down. The operators are checking
Entry  Thu Jul 1 16:27:57 2021, Andrew Nic, General, NTCAP parameters 
The latest recorded tdms files:
 p:\E143\sc\SC_2021-06-30_23-27-45\0000233
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001138
Entry  Thu Jul 1 15:25:42 2021, Rui-Jiu Chen, DAQ, template of NTCAP shift 
Please check following two parameters every two hours into make sure the NTCAP is running well: 
1. The latest recorded tdms files:
 p:\E143\sc\**\**
Entry  Thu Jul 1 14:47:15 2021, Yury, Helmut, Accelerator, added high Brho scrapers ESR-scraper-overview.jpgscrapers-used.JPG
So far only scrapers for low Brho were used:
  GE01DS_HI = -58mm (arc from inside) and
  GEEXDS2HA = -11.2 (straight from outside)
Entry  Thu Jul 1 07:28:55 2021, Jan, Akash, Accelerator, Beam intensity 
Intensity went up from 5e8 to 1e9 extracted particles from SIS.
Entry  Thu Jul 1 04:15:54 2021, David, Liliana, General, Beam intensity 
From 4:05 to 4:15 beam intensity was 1/2 as before. 
Entry  Thu Jul 1 01:35:15 2021, David, Liliana, General, Ion source change 
Changing ion source, no beam expected for the next 30 minutes.

2:15--> Beam is back, intensity not as high as before but will increase in the next few minutes as the source gets hotter.
Entry  Thu Jul 1 00:09:28 2021, David, Liliana, General, Low beam intensity for few minutes 
For few minutes (starting at 00:05) beam intensity went down. Same as it was reported by the previous shift. 
Until 00:27 beam had lower intensity than before (3e8) 
Now intensity is back to 5e8.
Entry  Wed Jun 30 23:29:42 2021, Rui-Jiu Chen, Analysis, Start a new run. 
reference level=-20 dBm.
p:\E143\sc\SC_2021-6-30_23_27_45
p:\E143\iq\IQ_2021-6-30_23_27_34
Entry  Wed Jun 30 20:58:06 2021, Ragan, Helena, General, Few minutes of disruption 
There was a disruption from the SIS side for a few minutes.
Entry  Wed Jun 30 20:14:44 2021, Ragan, Helena, General, Drop in SIS intensity 
There is a drop in SIS intensity and the operators are informed.
    Reply  Wed Jun 30 20:21:47 2021, Ragan, Helena, General, SIS intensity is back 
SIS intensity is back
Entry  Wed Jun 30 19:59:39 2021, Shahab, Runs, Scraper positions 
current scraper positions suggested by Sergey:

GEEXDS2HA = -11mm
Entry  Wed Jun 30 19:08:25 2021, Rui-Jiu Chen, Analysis, ID of 70Se spectrum recorded in May output_126.tofplot_242.0_245.0.pngplot_242.0_245.0.rootplot_242.0_245.0.pdf
 
Entry  Wed Jun 30 15:21:44 2021, Shahab, Runs, data synch on WWW server 
Data is being shared on the WWW server.
Time difference between the analyzers is in order of seconds:
Entry  Wed Jun 30 14:52:28 2021, Oliver, General, Re-Started data taking... 
Main user is finished. We started data taking again...
Entry  Wed Jun 30 14:48:54 2021, Oliver, General, Data taking - and not... 
We just started data taking. But a few minutes later the main experiment needed to do some adjustements to the beam. This interrupts us for a couple of
minutes...
Entry  Wed Jun 30 13:57:14 2021, Yuri, Sergey, Accelerator, sextupoles + scraper positions photo_2021-06-30_14-09-08.jpgphoto_2021-06-30_14-02-25.jpg
After setting up on 70Se
Sextupoles were adjusted to optimize the resolution of the 70Se peak. Set values are in the ESR logbook.
The SIS energy was shifted up to increase the number of 70Se.
Entry  Wed Jun 30 13:05:08 2021, Rui-Jiu Chen, Analysis, ID of 70Se 2021-06-30_11_54_00.png2021-06-30_11_54_00.pdf2021-06-30_11_54_00.rootoutput_127.tofoutput_128.tof
This is the latest ID of 70Se setting.
Entry  Wed Jun 30 13:04:40 2021, Shahab, Runs, 245 Amplifier on amplification_on245.png
turned on extra 20dB amplifier for the 245 Resonator around 12:32 
Entry  Wed Jun 30 12:35:53 2021, Rui-Jiu Chen, Analysis, Change reference level to -20dBm. Turn of amplifier. 
SC_2021-06-30_12_35_52
IQ_2021-06-30_12_35_43
Reference level=-20dBm
Entry  Wed Jun 30 12:26:58 2021, Rui-Jiu Chen, Analysis, NTCAP start. 
SC_2021-06-30_11-00-12
IQ_2021-06-30_11-00-12
reference level -80dBm.
Entry  Wed Jun 30 09:04:50 2021, Yuri, Markus, Accelerator, Status 
1) Over night the source was conservated. It is being restarted now.
2) The approximated amount of Gas in this bottle shall allow for running until tomorrow morning (~24 h). There is still another bottle in reserve (1 l)
and one reserve from GANIL (0.5 l).
Entry  Wed Jun 30 08:59:37 2021, Yuri, Accelerator, 70Se setting 
X(9Be)=1.815 g/cm2 (adjusted in primary beam setting)

Gamma_t=1.3956
Entry  Wed Jun 30 02:12:46 2021, Shahab, Runs, still no beam in ESR: quadrupole magnets are down 
still no beam in ESR: quadrupole magnets are down
Entry  Wed Jun 30 01:38:20 2021, Shahab, Runs, beam is back from Linac but not in the ESR 
 
Entry  Wed Jun 30 00:20:10 2021, Rui-Jiu Chen, Analysis, ID of 70Se setting on May plot_242.0_245.0.pngplot_242.0_245.0.pdfplot_242.0_245.0.rootoutput_126.tof
This is an old spectrum which was recoded on May.
Entry  Wed Jun 30 00:12:55 2021, Rui-Jiu Chen, Analysis, the ID of 72Ge setting plot_242.5_246.5.pngplot_242.5_246.5.rootoutput_127.tofplot_242.5_246.5.pdf
 
Entry  Tue Jun 29 21:15:01 2021, Kanika, Shahab, Runs, lost beam problem Unilac 
cooling water in UNILAC is out
Entry  Tue Jun 29 21:12:15 2021, Kanika, Shahab, Runs, Moving the resonance frequency of the 245 MHz resonator  e143_resonance_change_2.PNG
moving in the plungers:

before: 400
Entry  Tue Jun 29 21:10:30 2021, Shahab, Runs, 72-Ge setting 
the new setting is roughly 400 khz lower in frequency.
Previous beam time Ge was on 243.100 now it is on 242.74
Entry  Tue Jun 29 20:40:55 2021, Rui-Jiu Chen, DAQ, start NTCAP 
Carrier Frequency:245MHz.
IQ rate 20MSamples/s
Reference level:-90 dBm
Entry  Tue Jun 29 20:13:58 2021, Helmut, Sergey, Yuri, Accelerator, change to predrilling an 72Ge 
After optimisation of sextupoles we found a scraper position which makes a narrow peak and keeps 20% of the injected beam.
  GEEXDS2HA = +2.0 mm (out is +130mm)
  GE01DS_HI = -75 mm  (out is -130mm)
Entry  Tue Jun 29 10:32:10 2021, Sergey, Helmut, Accelerator, cooler curves for tuning of isochronicity isoc_curves.JPGiso_curves_june_2021_1.xlsx
Variation of quadrupole E01QS03D to change gamma_t in isoc. mode
measured with 78Kr at 368.5 MeV/u on 28.06.2021 evening.
The shape of the three curves looks very similar they would only require a different beam velocity.
Entry  Mon Jun 28 18:32:49 2021, Ruijiu, Shahab, DAQ, trigger signal connected to NTCAP and analyzers tri.jpg
 
Entry  Fri Jun 25 21:47:24 2021, Yuri, Analysis, Identification Spectrum_possible_ID.pngID_2nd_Part.jpg
Attached are two files with a proposed particle identification.
Different colors indicate different harmonic numbers
Entry  Thu Jun 24 22:05:11 2021, Helmut Weick, Accelerator, LISE files for 72Ge, 70Se, 52Mn settings E143_TEline-ESR-72Ge.lppE143_TEline-ESR-70Se.lppE143_TEline-ESR-52Mn.lpp
This is just a Brho selection by the ESR based on SIS-energy used, 
energy-loss in target with calibrated thickness and momentum spread by the reaction (Goldhaber formula).
Production cross sections are by EPAX 3.1
Entry  Mon May 10 08:49:01 2021, Kanika, Alex, RuiJiu, General, End of the measurement 
The beam was stopped at about 08:40.
Entry  Sun May 9 17:39:21 2021, Guy, Analysis, Comparison between 72Ge: 7th 19h vs 8th 21h 410MHz-05.09.19h-t11ms-sMontage.png410MHz-05.08.21h-t11ms-sMontage.png
Following Xiangcheng Chen's analysis, I analysed 11 ms time slices separated by 25 ms to see the evolution of the potential isomer across the injection.

Attachment 1: Data from May 7th 19h-20h. -t 11ms progression from -s=5 to -s=5.175
    Reply  Mon May 10 04:08:13 2021, Iris (Chris C., Jeff C.), Analysis, Comparison between 72Ge: 10th 1-2am on 245 MHz Sum_245MHz_May10-1-2am_5_0-5_175s.png
> Following Xiangcheng Chen's analysis, I analysed 11 ms time slices separated by 25 ms to see the evolution of the potential isomer across the injection.

> Attachment 1: Data from May 7th 19h-20h. -t 11ms progression from -s=5 to -s=5.175
       Reply  Mon May 10 05:25:29 2021, Iris (Chris C., Jeff C.), Analysis, Comparison between 72Ge: 10th 1-2am on 410 MHz 8x
Same as before, but for 410 MHz detectors.
Peaks visible in the 3rd-5th slice.
          Reply  Mon May 10 06:22:15 2021, Iris (Chris C., Jeff C.), Analysis, Comparison between 72Ge: 10th 1-2am on 410 MHz 9x
Same as before but for 4-5am on 410 MHz detector. Peak visible.

             Reply  Mon May 10 07:13:20 2021, Iris (Chris C., Jeff C.), Analysis, Comparison between 72Ge: 10th 5-6am on 410 MHz 9x
Same as before for 5-6 am.
Peak still there, maybe a bit less than before.
Entry  Mon May 10 06:35:58 2021, Kanika, Alex, Shahab, Runs, going back to shot by shot recording with 410 detector 
going back to shot by shot recording with 410 detector
Entry  Mon May 10 06:16:31 2021, Kanika, Alex, Shahab, Runs, Recording broad band spectra with 410 
doing some broadband spectra recording with the 410 MHz detector, for the purpose of future confirmation of identification lines.
Entry  Mon May 10 03:37:53 2021, Chris C, Analysis, isomer? or wishful thinking? E143-410MHz-2021.05.10.03.24.33.255.PNG
They are not easy to find, but we do occasionally see what might be the isomer.
Entry  Mon May 10 01:34:37 2021, Chris C, General, Zoom screenshot Zoom_monitoring_2021-10-05_0131CET.PNG
How things look currently in Zoom-world.
Entry  Mon May 10 01:01:59 2021, Kanika, Alex, RuiJiu, General, Beam is back 
The issue has been resolved and the beam is back since 00:56.
Entry  Mon May 10 00:51:38 2021, Kanika, Alex, RuiJiu, General, No beam in SIS 
The beam was lost in SIS about 5 mins ago due to the failure of HF cavities. Operators are trying to solve the problem.
Entry  Mon May 10 00:41:20 2021, Chris C, Accelerator, no beam 
Beam gone ~0:34.
Working on getting it back.
Back in business ~0:57.
Entry  Mon May 10 00:08:26 2021, Rui-Jiu Chen, DAQ, Change reference level to -60dBm  
Start a new run. The data of new run is in :
SC_2021-05-10_00-08-08
IQ_2021-05-10_00-08-08
Entry  Mon May 10 00:00:49 2021, Ragan, Rui-Jiu, DAQ, Change reference level to -70dBm 
Start a new run. The data of new run is in :
SC_2021-05-09_23-56-42
IQ_2021-05-09_23-56-42
Entry  Sun May 9 23:59:26 2021, Rui-Jiu Chen, DAQ, Start a new run. 
Start a new run. The data of new run is in :
reference level = -50dBm.
SC_2021-05-09_23-43-37
Entry  Sun May 9 23:32:24 2021, Helmut, Accelerator, parammodi saves 8x
Here are parammodi saves for TE-line and ESR for all four fragment settings:
For the first run of 72Ge (7.May) I do not have files.
Entry  Sun May 9 23:28:25 2021, Kanika, Alex, Wolfram, Helmut, Shahab, Runs, return with the Ge setting of the last night 
starting filenames:

E143-410MHz-2021.05.09.23.28.24.018.tiq
Entry  Sun May 9 23:24:49 2021, Helmut, Wolfram, Yuri, Accelerator, scraper optmisation for 72Ge 
We tried the scrapers a bit, because right of peak some background appeared.

The GE01DS_HI shows a strange effect,
Entry  Sun May 9 22:31:23 2021, Helmut, Wolfram, Yuri, Accelerator, change to 72Ge 
we change back to 72Ge
just change SIS-energy       E = 441.0 MeV/u
beamline energy after target E = 392.9 MeV/u
Entry  Sun May 9 21:29:26 2021, Helmut, Wolfram, Yuri, Accelerator, target TE3UF shift 
We see a very strong line at the left end of spectrum, stronger than all other lines.
When we shift the target TE3UF_H from -35mm to -37mm it gete weaker, but -37mm is the end of drive.
In the other direction it becomes worse. At -25mm completely new peaks.
Entry  Sun May 9 20:39:17 2021, Shahab, Runs, Subtracting the background spectrum_subtraction.png
still in the search of 70-Se
Entry  Sun May 9 20:34:47 2021, Rui-Jiu Chen, Analysis, Comparison of frequency spectrum between 72Ge and other isotope 6x
This some preliminary analysis results by using  NTCAP data.   The IQ rate of NTCAP is 20 MSamples/seconds. I analyzed data files recorded from May 7 
17:39 to May 8 2:20.  The frequency of 72Ge is bended by 4kHz at the beginning of some injections.  In order to check whether this frequency bending is
Entry  Sun May 9 19:03:02 2021, Rodostina, Oliver, Wolfram, Helmut, Yuri, Shahab, Runs, quadrupoles were down, fixed. 
 
Entry  Sun May 9 18:50:23 2021, Helmut, Wolfram, Yuri, Accelerator, changed to 70Se 
18:45  changed SIS, ESR setting for 70Se without predrilling blind change.
E-SIS =  446.55 MeV/u, is centerd as before on TE3UF target grid.
set beamline after taret as 78Kr 36+ E = 337.375 MeV/u
Entry  Sun May 9 18:41:33 2021, Rodostina, Oliver, Wolfram, Helmut, Yuri, Shahab, Runs, stopped data taking for energy change 
last recorded filename:

E143-245MHz-2021.05.09.17.38.44.410.tiq
Entry  Sun May 9 16:19:06 2021, Rodostina, Oliver, Wolfram, Shahab, Runs, Setting to 52Mn ???? 
first filename in this recording:

E143-245MHz-2021.05.09.15.16.49.816.tiq
Entry  Sun May 9 14:19:44 2021, Yuri, Accelerator, Spectrum 
We accept larger m/q values than we like to. m/q(low) cut ~ 2.08. Decrease ESR energy from 369.2 -> 368.4 MeV/u
frequencies shifted by -37.5 kHz (at 60 MHz)
Entry  Sun May 9 13:53:07 2021, Yuri, Wolfram, Andrew, Liliana, Calibration, Change of energy: Back as before Screenshot_2021-05-09_13-59-36.png
After looking at the spectrum it was concluded that the same isotopes, and no more, could be identified. 
Now we change the energy back to 441.7 MeV/u and will open the scrappers to see if Mn comes in. 
Entry  Sun May 9 13:15:38 2021, Liliana Andrew, Runs, Stopped data taking during modifications for the beam energy Screenshot_2021-05-09_13-25-26.png
Beam energy to be increase to move Mn into the ring. 
First step we set the energy to 445 MeV. 
The effect of the change can be seen on the plot: Right is how it was before and left after the change. 
Entry  Sun May 9 12:53:01 2021, Desislava Kalaydjieva, Taka Yamaguchi, Analysis, Analysis, Morning shift, 9 May 9x
For the whole morning shift there were no significant changes in the spectra.

Some of the obtained histograms are attached below. 
Entry  Sun May 9 08:00:03 2021, Liliana, Andrew, General, Status  Screenshot_2021-05-09_08-01-17.png
So far, we keep the setting as it is and wait for experts to come in. 
Few spills are missing from time to time. One of the peaks stays usually in the spectrum when this happens. 
Analysis of the last hours is being performed by the remote shift, in case it is useful. Some plots in telegram. 
Entry  Sun May 9 06:34:37 2021, Iris, Chris G., Jacobus, Michele, Analysis, Runs 2-3am Not_Mn52 Not_52Mn_245MHz_May09_2-3am_s0_1_t8_0.pngNot_52Mn_245MHz_May09_2-3am_s0_1_t8_0.rootNot_52Mn_245MHz_May09_2-3am_s5_1_t0_5.pngNot_52Mn_245MHz_May09_2-3am_s5_1_t0_5.root
Summed up runs on the 245 MHz detector between 2-3am (computer time).
One has -s 0.1 -t 8.0
the other -s 5.1 -t 0.5
    Reply  Sun May 9 07:16:47 2021, Iris, Chris G., Jacobus, Michele, Analysis, Runs 3-4am Not_Mn52 Not_52Mn_245MHz_May09_3-4am_s0_1_t8_0.rootNot_52Mn_245MHz_May09_3-4am_s0_1_t8_0.png
Summed up runs on the 245 MHz detector between 3-4am (computer time).
-s 0.1 -t 8.0
Entry  Sun May 9 06:53:20 2021, Iris, Chris G., Jacobus, Michele, General, Summary night shift 
The tune last night was unfortunately not to 52Mn. The two "isomers" that were identified are instead 45Sc and 75Br. But separation looks okay. ESR morning
shift should try to tune to 52Mn to identify the 21-min isomer at 378 keV.
Entry  Sun May 9 02:45:50 2021, Jacobus, Michele, Shahab, Runs, Example of possible 52.Mn isomer 52Mn_002.PNG
this is how it should look like
    Reply  Sun May 9 02:51:44 2021, Iris, Runs, Example of possible 52.Mn isomer 
So the "isomers" pop up at ~-600 Hz and +580 Hz... is the -600 Hz on the left the 378 keV isomer (21 min) and the +580 Hz on the right the g.s.?
       Reply  Sun May 9 03:24:12 2021, Iris (Shahab, Jacobus, Chris G., Michele), Runs, Example of possible 52.Mn isomer 
Short update from Yuri: these are not our isomers. These are 45Sc (left, 12 keV isomer not resolvable) and 75Br (center), and the right-most peak of the
triplet is a satellite (has a different line shape, much narrower).
          Reply  Sun May 9 06:15:09 2021, Iris, Chris G., Jacobus, Michele, Runs, Triplet: zoom in 116-triplet.png
Zoom into the triplet: the satellite peaks on the right are clearly visible.
This is just one file but one *might* see some substructure. Yuri mentioned a 318 ms isomer in 45Sc at 12 keV but that cannot be resolved.
Entry  Sun May 9 05:56:29 2021, Iris, Chris G., Jacobus, Michele, Analysis, Not_52Mn spectra added up Not_52Mn_245MHz_May09_1-2am.pngNot_52Mn_245MHz_May09_1-2am.root
Attached is a summed spectra of all files taken between 1:17am and 1:59am (on the 245 MHz detector).

python3 e143_analyzer.py -s 5.1 -t 0.5 /home/dillmann/E143/e143-scripts/sparc-daq-02.gsi.de/E143-245MHz/E143-245MHz-2021.05.09.01.* -o Not_52Mn_245MHz_May09_1-2am
Entry  Sun May 9 05:38:29 2021, Iris, Chris G., Analysis, offset btw png and tiq files from server? comp-116.png
This might have been answered before but I looked at one png file and one tiq file from the same run that was stored on the server. There seems to be an
offset of 2.2 s. The png file from the server (right) shows the injection at ~5s, whereas when I look at the tiq file in the GUI (left), the injection
is at ~2.8 s???? Is the looper introducing this offset?
    Reply  Sun May 9 05:54:11 2021, Ragan, Analysis, offset btw png and tiq files from server? 
This is due to the 50% trigger setting in the spectrum analyzers ))
Entry  Sun May 9 02:19:04 2021, Jacobus, Shahab, Runs, First 52Mn run  
Run E143-245 MHz-2021.05.09.01.17.42.265.tiq is the first run of the experiment on 52Mn.
    Reply  Sun May 9 05:11:55 2021, Iris (Chris G., Jacobus, Michele), Runs, First 52Mn run (no 52Mn unfortunately) 
> Run E143-245 MHz-2021.05.09.01.17.42.265.tiq is the first run of the experiment on 52Mn.

Entry  Sun May 9 04:15:50 2021, Michele, Jacobus, Shahab, Runs, Beam issues for short duration 

ESR warning (colour red in the panel)
Entry  Sun May 9 02:32:58 2021, Jacobus, Shahab, Runs, possible 52-Mn isomer E143-245MHz-2021.05.09.01.23.19.468.tiq.pngasd.jpg
the intensity of the line on the left side is so high, it is difficult to see the isomers in the middle as can be seen in the auto generated picture
Entry  Sun May 9 01:49:25 2021, Helmut, Sergey, Yuri, Accelerator, change to 52Mn 

It was done in steps:
isochronous 52Mn should come at Brho = 6.28239 Tm (gamma_t = 1.3955).
Entry  Sun May 9 01:19:47 2021, Helmut, Sergey, Accelerator, scraper optmisation for 72Ge IMG_20210508_210509.jpg
To improve the isochronicity still in the 72Ge setting sextupoles and scrapers wer varies successfully.

1. E02DS_H -130 / 130mm  - wide rect. peak
Entry  Sat May 8 22:06:36 2021, Michael, Ruijiu, Helmut, Yuri, Wolfram, Sergey, Shahab, Runs, stopped data taking with the high resolution 
last file names with this setting:

245: 2021.05.08.20.42.03.743.tiq
Entry  Sat May 8 21:42:51 2021, All, Accelerator, Set up for 52Mn 
Details will follow
E(Mn) = 368.41 MeV/u
Entry  Sat May 8 21:42:26 2021, All, Runs, Stop72Ge 
 
Entry  Sat May 8 21:10:24 2021, Michael, Ruijiu, Helmut, Yuri, Wolfram, Sergey, Shahab, Runs, started data taking with high resolution E143-245MHz-2021.05.08.20.17.39.000.tiq.pngE143-410MHz-2021.05.08.21.18.51.447.tiq.png
after optimizing the scrapers we have reached the highest possible resolution in the isochronous mode.

starting data taking with this new settings.
Entry  Sat May 8 21:08:13 2021, Helmut, Sergey, Shahab, Wolfram, Yuri, Accelerator, optimisation of sextuples 
The optimisation of sextuples is finished. Record a few files.
Entry  Sat May 8 19:51:46 2021, Ragan, Rui-Jiu, DAQ, Change reference level to -50dBm 
Start a new run. The data of new run is in :
SC_2021-05-08_19-51-35
IQ_2021-05-08_19-51-35
Entry  Sat May 8 18:35:25 2021, Rui-Jiu Chen, DAQ, Change reference level to -10dBm 
The beam in ESR is 78Kr36+@476 MeV/u.
Start a new run:
SC_2021-05-08_18-25-52
Entry  Sat May 8 17:29:54 2021, Yuri, Sergey, Wolfram, Michael, Shahab, Runs, recording Kr decay measurement on NTCAP 
Uc = 250mA
decay Kr 78, 476 MeV/u
Entry  Sat May 8 16:08:58 2021, Helmut Weick, Accelerator, beam position of Kr before ESR TE3DG3-Kr.JPGTE3DGC-Kr.JPGTE5-grids-Kr.jpg
Checked beam positions in beamline before ESR,
they all look the same as before, with direct Kr beam.
Compare with old elog entry #.
Entry  Sat May 8 15:18:23 2021, Michael, Wolfram, Yuri, General, Beam Settings changing 
Beam settings are being changed back to 78Kr beam at 467 Mev/u. 
Entry  Sat May 8 11:42:21 2021, Yuri, Accelerator, KPs 
EO1KP03 was on = -44.9 A
E01KP05 was off, now is on = 3.67 A
The beam is on the right frequency, but the width is still very broad.
Entry  Sat May 8 10:51:41 2021, Akash, Nic, Jelena, Zsolt, Calibration, ESR settings seem different Screenshot_2021-05-08_at_10.50.23.png
Settings don't look the same...so we are not yet writing files unless sure.
Entry  Sat May 8 08:44:32 2021, Akash, Nic, Jelena, Zsolt, Accelerator, No Beam! 
08.43am: Beam stopped. HKR looking into it. Reason: they mentioned they don't know yet!

10.10am: SIS resumed operations. However, there are some issues with magnet power supplies for ESR and hence we still don't have beam. HKR member went
Entry  Sat May 8 08:16:08 2021, Akash, Nic, Jelena, Zsolt, Analysis, Night shift analysis 16x
(Jelena has analysed these data files)

E143_245MHz_2021.05.08.00* (-s 5.0 -t 0.5)  (2021.05.08.09.01.11.png)
Entry  Sat May 8 08:12:02 2021, Akash, Nic, Jelena, Zsolt, General, SIS, ESR time structure changes Screenshot_2021-05-08_at_08.08.14.png
The structure of SIS extraction seems to have changed a little...also for ESR injection.

In the span of a few minutes both the structures changed again...to look more like in the previous shifts, with lesser or no negative component.
Entry  Sat May 8 07:34:08 2021, Akash, Nic, Jelena, Zsolt, General, Zoom has its own mind 
Zoom kicked us all out... we managed to get back in...screen sharing is back on.
Entry  Sat May 8 07:14:00 2021, Akash, Nic, Jelena, Zsolt, General, Morning shift entry 
Things look ok. No settings have been changed...

Analysis attempts are going on...
Entry  Sat May 8 03:08:57 2021, Rui-Jiu Chen, DAQ, Change reference level to -50dBm 
Start a new run. The data of new run is in :
SC_2021-05-07_17-39-16
IQ_2021-05-07_17-39-16
Entry  Sat May 8 03:05:42 2021, Rui-Jiu Chen, DAQ, Change reference level to -60dBm 
Start a new run. The data of new run is in :
SC_2021-05-07_17-33-29
IQ_2021-05-07_17-33-29
Entry  Sat May 8 01:43:23 2021, Helmut Weick, Accelerator, 70Se setting 
If gamma_t = 1.3955 Tm stays, we will need Brho = 6.21902 Tm for 70Se.
The corresponding ESR Brho setting will be a bit shifted.
It then requires E-SIS = 446.55 MeV/u to get 70Se to this Brho and gamma_t.
Entry  Sat May 8 01:33:25 2021, Helmut Weick, Simulations, frequency list for 70Se setting freq-lines-70Se.JPGfrag-freq-list.xlsx
EXCEL table with all possible fragments injected into ESR.
The path length in ESR, gamma_t and harmonic are adjusted to the 72Ge data. 
Some lifetimes are limited but all intense lines are >30s in lab system.
Entry  Sat May 8 01:06:19 2021, Philipp, Marta, General, Screenshot Screenshot_2021-05-08_at_00.58.16.png
The signal of the transformer on the lower right panel is not really beam related. It is mostly noise. Changes are not so expected with this low beam intensity
Entry  Sat May 8 00:38:55 2021, Philipp, Marta, General, Screenshot Screenshot_2021-05-08_at_00.32.16.png
 
Entry  Fri May 7 23:08:44 2021, Michael, Kanika, Accelerator, Beam issues for short duration 
The beam was lost for a few minutes from 23:01 to 23:06. It is back now.
Entry  Fri May 7 22:48:33 2021, Chris, General, still running... E143-245MHz-2021.05.07.21.46.10.889.tiq.pngZoom_screenshot.PNG
In anticipation of the imminent shift change, a snapshot of how things look.
Entry  Fri May 7 22:00:36 2021, Chris, Accelerator, brief beam loss 
Brief interruption in beam, ~21:42-21:51.
Entry  Fri May 7 20:34:27 2021, Kanika, Michael, Shahab, Runs, back to 15 sec recording 
now we are going back to 15 sec operation. Cave M (bio) operation is over
Entry  Fri May 7 20:28:32 2021, Kanika, Michael, Shahab, Analysis, Some pictures from the 410 detector 9x
some pics.
Entry  Fri May 7 19:56:10 2021, Kanika, Michael, Shahab, Runs, ZOOM session restart 
restart zoom session
Entry  Fri May 7 18:43:13 2021, Kanika, Michael, Shahab, Runs, cave M experiment needs more spills rep.jpg
our pattern causes beam loss while scanning the biological probes in the Cave M bio experiment. They loose every other spill due to high request rate from
ESR.
Entry  Fri May 7 18:08:35 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, going back to the original energy 
going back to the original energy 441 MeV/u

last filenames with the previous energy:
Entry  Fri May 7 17:35:22 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, Energy change +6 MeV/u 
We will now go up in energy to 447 MeV (+6 MeV) from the original energy

last file name with previous energy:
Entry  Fri May 7 17:12:52 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, trigger time back to 50% 
changed trigger time back to 50%

last file with 1% trigger: 
Entry  Fri May 7 17:12:14 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, Energy change -6 MeV/u 
changed the energy down to 435 MeV/u
Entry  Fri May 7 17:02:51 2021, Kanika, Sergey, Yuri, Wolfram, Michael, Shahab, Runs, new sextupole setting 2 
There is new sextupole settings, but the scrapers remain like last night (Helmut setting last night.)
Entry  Fri May 7 16:17:21 2021, Sergey, Yuri, Wolfram, Shahab, Runs, new sextupole setting 
new sextupole setting, isomer not visible yet.
Entry  Fri May 7 16:09:50 2021, Yuri, Accelerator, Stop, change of sextuple settings 
 
Entry  Fri May 7 14:33:23 2021, Andrew Ragan Yuri , General, Beam is back 
 
Entry  Fri May 7 14:06:02 2021, Yuri, Accelerator, SIS kicker failure 
 
Entry  Fri May 7 12:37:35 2021, Ragan, Andrew, Yuri, Alex, General, Back with beam  
We are back with the beam in the ESR since 12:30
ALL SCRAPERS ARE IN THE ORIGINAL POSITIONS
E02DS3HG = - 35 mm
Entry  Fri May 7 11:40:20 2021, Ragan, Andrew, Yuri, General, Scraper is fixed - optimisation stage 
Scraper is fixed, we start again. Scraper open to let everything through
Entry  Fri May 7 10:46:40 2021, Yuri, Accelerator, GE02DS3HG 
The scraper is blocked at -10 mm and -unfortunately- blocks the beam in the ESR. Uli Popp is taking care.
Entry  Fri May 7 10:05:06 2021, Yuri, Accelerator, E02DS3HG does not drive 
E02DS3HG stays at -35 mm and does not react
Entry  Fri May 7 09:58:04 2021, Yuri, Accelerator, Setting up KO extraction for Caves 
SIS optimisation requires us to stop. Only sporadic shots.
Entry  Fri May 7 09:56:43 2021, Yuri, Calibration, Identification Verification 
With closed scrapers there are only a few weak lines.
Open temporarily all scrapers in the ESR to write down the frequencies. 
Entry  Fri May 7 09:36:32 2021, Ragan, Andrew, Yuri, General, Beam stop at 0928, adjust scope 
It was requested from the SIS to stop the beam at 09:28 
Yuri is adjusting the scope in order to avoid UFO (unidentified frequency object)
Entry  Fri May 7 08:55:33 2021, Ragan, Andrew, Yuri, General, Trigger changed photo_2021-05-07_08-58-58.jpg
Trigger for both the spectrum analyzers is changed from 50% to 1% by Yuri.
For this, the ESR pattern was stopped at 08:50 and was started back at 08:53.
Entry  Fri May 7 08:04:22 2021, Carlo Bruno, Desislava Kalaydjieva, Analysis, 7:00 - 14:00 analysis shift 15x
(See
https://triumfoffice365-my.sharepoint.com/:w:/g/personal/dillmann_triumf_ca/Eb_LCp7yTx5Bgc8TO8khJmEBWeS-ycdPRnG02wQout-fgQ?rtime=3n3A3xMR2Ug
for remote shifter instructions. To be updated/corrected by the experts)
Entry  Fri May 7 07:52:12 2021, Ragan, Andrew, General, To change trigger position 
Xiangcheng suggested to change the trigger position in order to start the file with the injection. Nothing is changed at the moment. Maybe Shahab or Yuri
can do it when they arrive.
Entry  Fri May 7 07:02:33 2021, Guy Leckenby, Analysis, Online Monitoring Plots E143_spec_1sec.png
In compliment to Liliana's plots, this is the summed spectra I calculated from 0338 to 0507.
Entry  Fri May 7 06:53:56 2021, Akash, Liliana, Analysis, Some plots 6x
Some plots of statistics up to now
Entry  Fri May 7 04:39:00 2021, Liliana, Akash, Wolfram, Helmut, Shahab, Runs, Data taking starts 
File start being recorded at 4:38 am 
Sync with the server is working. 
Entry  Fri May 7 04:26:54 2021, Shahab, Runs, 245 MHz resonator extra 20dB gain off 
made sure that the extra 20dB amplifier is off.
Entry  Fri May 7 04:01:51 2021, Shahab, Runs, Picture after scraping pic.jpg
this picture is after scraping by helmut, showing the 410 MHz detector, that is we would expect an isomer where the marker M1 is, i.e. at 2.2kHz on the
left side, which we unfortunately don’t see (yet).
Entry  Fri May 7 03:51:56 2021, Shahab, Analysis, peak frequencies New_Doc_6_1.jpgNew_Doc_6_2.jpg
a reference schematic of the peaks on 410 MHz (211th harmonic) and 245 MHz (126th harmonic)
Entry  Fri May 7 03:46:58 2021, Liliana, Akash, Wolfram, Helmut, Shahab, General, Scraper settings IMG_20210507_034213_resized_20210507_034848181.jpg
Scraper settings have been played around with to try and remove satellite lines...

Helmut has now set scraper id GE01DS_H at -45mm (in position)
Entry  Fri May 7 03:44:55 2021, Helmut Weick, Accelerator, scraper optimisation 
Opened TE4 slits again to +/-10mm.

Then we tried different scrapers:
Entry  Fri May 7 03:33:11 2021, Liliana, Akash, Wolfram, Helmut, Shahab, General, status 
At the moment we see a second peak to the left of each intense line. 
The distance between the main peak and the shadow is roughly the same for each peak.
This hints to a sharp fall in the isochronicity curve.
Entry  Fri May 7 02:01:08 2021, Liliana, Akash, Wolfram, Helmut, Shahab, Accelerator, Beam issues for short duration 
RFQ fall-out (HKR working on it...)

Beam stop time: 01.58am
Entry  Fri May 7 01:49:03 2021, Rui-Jiu Chen, DAQ, Comparison of I_Raw/Q_Raw between different reference level  20210501_NTCAPPreparation.png
This is a comparison of I_Raw/Q_Raw between different reference level. The range of NTCAP ADC is only 2^15 bit. So signals (I_Raw and Q_Raw) should 
not be outside ADC range. It is clear that there is not point outside the ADC range when using reference level -30dBm.
Entry  Fri May 7 01:47:36 2021, Ragan, Rui-Jiu, DAQ, Change reference level to -30dBm  
Reference Level: -30 dBm.

Start taking data.
Entry  Fri May 7 01:44:24 2021, Rui-Jiu Chen, DAQ, Change reference level to -40dBm 
Reference Level: -40 dBm.

Start taking data.
Entry  Fri May 7 01:07:27 2021, Helmut Weick, Analysis, maybe frequency ID frequencies.JPG
We think we see the frequency range of A/q=2.25 at 243.1 MHz.
This would correspond to L=108.2m and E=386.4 MeV/u (gamma_t = 1.3955) at h = 126.
Path length is a bit short, for L=108.4m it should be 370.6 MeV/u. 
Entry  Thu May 6 23:06:18 2021, Rui-Jiu Chen, DAQ, Change reference level to -50dBm 
Beam is secondary beam now. The intensity is lower. Change reference level to -50dBm.
Carrier frequency:245MHz
IQ rate(S/s): 20M.
Entry  Thu May 6 22:05:30 2021, Helmut, Accelerator, Beamline and ESR data sets for 72Ge setting 2021-05-06_22-07-09_SIS18_FAST_20210506_ESR_78KR32.C1.txt2021-05-06_22-07-52_ESR_EXP21_06_ISO_78Kr_05May21.C1.txt
parammodi exports, E-SIS = 441.0 MeV/u with Be-1840 mg/cm² target in, isoc. ESR, at least we see fragments
Entry  Thu May 6 21:45:30 2021, Helmut, Detectors, beam position on TE5 grids 2021-05-06_21-32-36-171.png
The two grids do not work very well, one x position is opposite to the other.
But at least a guidance for the future, this was good injection of 78Kr with a thick Be target.
Entry  Thu May 6 21:36:04 2021, Regina + Markus + Yuri, Accelerator, Cooler Curve cc_1.jpg
Final cooler curve, Isochronous 78Kr
Entry  Thu May 6 21:26:02 2021, Yuri et al., Accelerator, Energies 
gamma_t = 1.3955
Br(72Ge) corresponds to 6.79575 Tm
E (Kr) at Br(72Ge) = 392.9 MeV/u
Entry  Thu May 6 18:21:42 2021, Ragan, Rui-Jiu, DAQ, NTCAP started again IMG_20210506_182118.jpgIMG_20210506_182017.jpg
NTCAP was stopped at 17:34 for the optimisation purpose.
NTCAP started again at 18:20 with the change in Reference Level (dBm): 0
Entry  Thu May 6 17:48:48 2021, W. Korten, Helmut, General, ESR setting for 72Ge ions with primary beam  
Setting the 78Kr (after the target) to the Brho of the 72Ge beam at 368.4 MeV/u (gamma=1.3955), i.e. 6.79575 Tm, which leads to an energy of 392.93 (of
78Kr). 
With the 10mm Be target the beam energy should then be 467.8 MeV/u .
Entry  Thu May 6 17:02:49 2021, Ragan, Rui-Jiu, DAQ, Scaler signals and parameters of NTCAP p1.JPGp2.JPGp4.png
At the moment, we record 7 signals in scaler channels and one Schottky signal (245 MHz resonance cavity) in the NTCAP with the attached information.
Entry  Thu May 6 16:45:42 2021, Ragan, Rui-Jiu, DAQ, Data taking with NTCAP 1.jpg2.jpg
NTCAP is on and data taking has started.
On time: 16:39
Entry  Thu May 6 14:30:23 2021, W. Korten, General, Target thickness 
Thickness of the Carbon target in the TE line has been measured by centering the primary 78Kr beam in the ESR:
Beam energy 370 MeV/u, with thin stripper, ESR energy 368.65 MeV
Adjust beam with "thick" target to keep ESR energy at 368.65 MeV/u -> Beam energy 445 MeV/u
Entry  Thu May 6 14:28:32 2021, Helmut Weick, Calibration, Be target thickness calibration -> 1839 mg/cm^2 
Injection was optimized before with Cu-40 mg/cm^2 stripper.
This reduces energy of 78Kr from 370 MeV/u -> 386.52 MeV/u.
To keep the same ESR injetion the SIS energy was raised with Be 10mm tatget.
Entry  Thu May 6 13:26:56 2021, Helmut Weick, Detectors, TE5 profile grids do not work no_trigger.png
There are several issues.

1. The stepper motor drive does not react from Device-Control, -> check controller in FRS Messhütte
Entry  Thu May 6 00:32:57 2021, Helmut Weick, Simulations, GICOSY file for TE beamline and ESR SIS-TE-ESR-isoc-std.datTE-ESR.JPG
This file has several options:
start in SIS, at TE3UF target or inside ESR, choose with GOTO LABEL (G L)after start system (S S).
Depending on the choice select different start beam parameters at top of file, others comment out.
Entry  Tue May 4 21:49:04 2021, Helmut Weick, Simulations, cut Brho by scrapers dispersion-oscillaction.JPG
The dispersion from the production target into the ESR is not matched.
This is not good for momentum acceptance, but we anyway want to cut the acceptance.
Dispersion will oscillate with the tune of ESR. After 3 turns we expect a maximum dispersion. 
Entry  Tue May 4 18:25:31 2021, Helmut Weick, Simulations, cutting of primary beam TE4-slits.JPGTE5-slits.JPG
The slits at TE4 and TE5 can be used to cut away the unwanted 78Kr beam (see pictures).
We do not want activation of the beamline. 78Kr35+ even has a chance of being injected.
Entry  Tue May 4 17:54:08 2021, Helmut Weick, Simulations, updated LISE file E143_TEline-ESR-2.lpp
This file really has the optics like used in the last ESR experiments.
Now the transmission is also a little bit better.
Entry  Tue May 4 13:26:40 2021, Yuri, Simulations, Expected spectrum 72Ge 
A       Z      M/q                Int    difference in kHz@245MHz
68 30 2.263614752 35 -933.1
70 31 2.255131564 124 -457.0
Entry  Wed Apr 28 09:36:39 2021, Helmut Weick, Simulations, LISE file for fragments from TE3UF into ESR E143_weick.pptxE143_TE-ESR.lpp
Uncooled beam on target at TE3UF with dispersion and slit in TE beamlne and realistic injection into ESR.
Now tuned for 72Ge but can easily be modified to other fragment settings. 
The target thickness may need adjustemet after measurement.
Entry  Fri Apr 23 13:47:55 2021, Jan Glorius, Collaboration, experiment proposal ESR_Two-Photon_proposal_final.pdf
 
ELOG V3.1.5-fc6679b