ID Date Author Category Subject Text Attachments
  84   Mon Mar 25 05:21:18 109 Ken UeberholzDetectorsXUV-Detector RatesCount rates were measured for the XUV-
detector for a full circle:
Cathode: -5V, shields: 0V, main coil 8A,
 Screenshot_20220404-000343_Gallery.jpgScreenshot_20220404-000327_Gallery.jpgScreenshot_20220404-000411_Gallery.jpg 
  237   Wed Apr 20 10:09:50 2022 RodolfoLaserOptic with spotsThe average energy produced by the laser along
the beamtime was about 10 mJ/puls. After
about two weeks of beamtime some of the optics,
 SHG_Compensator_mitFleck_19-04-2022.jpgUV_Umlenkspiegel_mitFleck_19-04-2022.jpg 
  236   Sat Apr 16 04:19:05 2022 Patrick, Simon, Alex, SarperRunsRuns night + morning shifts 16.04.Runs of the night shift 16.04. after changing
the wavelength range. The new range is 320.12
- 319.859 nm. The step size was decreased
  
  235   Fri Apr 15 20:43:18 2022 KonstantinLaserDye changedDye of the laser system has been changed.
UV laser power increased from ~8 mJ to 11
mJ pulse energy.
  
  234   Fri Apr 15 12:53:25 2022 Max, DanyalLaserchecked laser pulse energy after change in wavelength rangeprevious scan range: 
the laser pulse energy @ 320.62 nm  was ~11
mJ 
  
  233   Fri Apr 15 12:42:18 2022 Max, Danyal, Carsten, Konstantin, Patrick, SimonGenerallaser wavelength range changed: 320.12 - 319.60 nm
Runs of the morning/afternoon/night shift.
The wavelength range is now 320.12 - 319.60
 VoltageJump1830.PNG 
  232   Thu Apr 14 22:44:40 2022 Patrick, Simon, Danyal, MaxRunsRuns night shift 14./15.04.Runs of the night shift. The wavelength range
is 320.62 - 320.10 nm.
  
  231   Thu Apr 14 19:46:46 2022 Sarper & Konstantin & RodolfoLaserLaser powerWe checked the laser power before starting
the new scan range.
  
  230   Thu Apr 14 17:47:55 2022 Carsten, Rodolfo, Konstantin, SarperRunsAfternoon shift runs 14.04 changing the wavelength scan rangeThe new scan range is changed from [B]321.12
- 320.60 nm to 320.62 - 320.10 nm[/B]
  
  229   Thu Apr 14 12:38:38 2022 SebastianDetectorsXUV / Cu checkupsCheck regularly if the connection to the XUV
and Cu detectors are still active and the
detectors move in (after injection) and out
  
  228   Thu Apr 14 12:27:18 2022 Sebastian, MaxDetectorsConnection to XUV / Cu reestablished!The connection to the XUV and Cu were lost
during the nightshift.
  
  227   Thu Apr 14 10:57:11 2022 CarstenAcceleratorMaintanence UNILAC / Op trainingWe had no beam since about 1000. Also, we
are still trying to find out why we have
such a low intensity in the expereimnt. 
  
  226   Thu Apr 14 08:41:42 2022 CarstenAcceleratorLow intensity at the experiment after series of failures during the nightAfter the recovery from the failures during
the night, we see much lower intensity at
the experiment (measured with the particle
  
  225   Thu Apr 14 06:29:18 2022 Max, SebastianAcceleratorlesser ESR injection intensityWe now have less ESR injection intensity (see
screenshot attached).
 2022_04_14-lowCountRate-LesserESRInjection-SchottkyIntensity.JPG 
  224   Wed Apr 13 15:41:29 2022 Rodolfo & SarperLaserLaser statusWe have checked the power of the laser and
optimized it "a bit".
  
  223   Wed Apr 13 14:29:04 2022 Carsten, Rodolfo, Sarper, David, Pierre-Michel, Max, SebastianRunsAfternoon - morning shift runs 13.+14.04.Changed the wavelength scan range from [B]321.62
- 321.10 nm[/B] to [B][B]321.12 - 320.60[/B]
nm[/B] after one scan.
 coolerProblemsAndFragments.JPGfragments.JPGBroaderIonBeam.JPGagainNormalWidth.JPG 
  222   Tue Apr 12 21:56:54 2022 Volker, David, Pierre-Michel & Danyal, Alexandre, SebastianGeneralnew laser wavelength scan range 321.62 - 321.10 nmNew wavelength scan range is [B]321.62 - 321.10
nm[/B]. Before the new scan range (compare
old scan range in [URL=https://elog.gsi.de/esr/E142/215]
 Ecooler12VdropOn13_04_22_9_52am.pngEcooler18VEcoolerJumpOn13_04_22_13_18pm.png 
  221   Tue Apr 12 17:01:30 2022 KonstantinDetectorsVoltage PMT NorthVoltage of PMT North has been increased from
2500 V to 2600 V. Additionally the threshold
was adapted from 25 mV to 12 mV.
  
  220   Tue Apr 12 15:05:56 2022 RodolfoLaserLaser statusWe have checked the laser power at 14:15 *

- Pump energy after Q-Ray @ 532nm: 559 mJ.
  
  219   Tue Apr 12 14:52:19 2022 RodolfoDetectorsPMT Nord, Middle. DatasheetsAttached are the datasheets for the solar-blind
PMTs.
 ET-Enterprises_DataSheets_PMT_9423-9422.pdf 
  218   Tue Apr 12 14:11:52 2022 RaganDetectorsSideband in Schottky> Sometimes we see a broad sideband at lesser
Schottky frequencies to the high-intensity
thorium beam.
  
  217   Tue Apr 12 13:24:40 2022 Alexandre, SebastianDetectorsSideband in SchottkySometimes we see a broad sideband at lesser
schottky frequencies to the high intensity
thorium beam.
 IMG_20220412_125530_resized_20220412_125736155.jpgIMG_20220412_125643_resized_20220412_125736537.jpg 
  216   Tue Apr 12 12:41:20 2022 Alexandre, SebastianAcceleratorno beam in SIS18    
  215   Tue Apr 12 04:43:29 2022 Alexandre, Kristian, SebastianRuns322.01 - 321.60 nm We scan the wavelength scan range is  322.01
- 321.60 nm 
 DriftingVoltage14-40.PNG 
  214   Mon Apr 11 22:33:16 2022 CarstenGeneralBackup of data to the external RAID disks    
  213   Mon Apr 11 22:14:51 2022 Konstantin, SarperLaserChanging of the wavelength rangeIt is planned to change the scan range of
the laser wavelength from 322.41 - 322.0
nm to 322.01 - 321.6 nm @ 4 a.m. 
  
  212   Mon Apr 11 18:57:18 2022 RodolfoLaserNew flashlampsWe (Sarper, Konstantin and me) have changed
the old flashlamps (with ~ 26 Mio. shots)
by new "fresh" ones. We have also exchange
 Blitzlampe_26Mio_Schüsse_11-04-2022.jpg 
  211   Mon Apr 11 18:46:31 2022 Rodolfo, Sarper and KonstantinLaserAlignment-checkWe cross-checked the laser-ion alignment.
The horizontal position was optimized. However,
 MRC_Konfiguration_MitMainAmp_04-11-2022.png 
  210   Mon Apr 11 14:45:11 2022 Paul, Konstantin, Sarper, DavidRunsAfternoon shift runs 11.04We continue scan the new wavelength scan range
is  322.41 - 322.00 nm 
  
  209   Mon Apr 11 12:50:22 2022 KristianAcceleratorTh lifetimeWe used the counter to measure the lifetime.
During the 30 min scan time dropped only
slowly. 
 ThLifetime.JPG 
  208   Mon Apr 11 11:05:35 2022 Sebastian, KristianLaserCheck laser powerwe checked the UV laser power at 10:15 am.
It was only 8.5 - 9 mJ. Pumping power was
460 mJ, which is the maximum output of the
  
  207   Mon Apr 11 10:31:07 2022 Kristian, Sebastian, Alexandre, Danyal, PaulGeneralnew laser wavelength scan range 322.41 - 322.00 nmnew wavelength scan range is  322.41 - 322.00
nm 
  
  206   Mon Apr 11 10:17:01 2022 DanyalAcceleratorInterlock - reset 10:17 
Wie heutemorgen in der Sitzung (morning briefing)
vereinbart, 
  
  205   Mon Apr 11 07:54:37 2022 Danyal, Alexandre, Kristian, SebastianAcceleratorJump in E-cooler voltageWe saw a jump in the E-cooler voltage at about
7:50. 
jump from 209619 to 209610 V 
  
  204   Mon Apr 11 04:26:53 2022 PatrickDAQNext wavelength rangeMeasurements with the next wavelength scan
range should be started roughly around 10:00
am.
  
  203   Sun Apr 10 22:47:05 2022 Patrick, Volker, Prannay, Danyal, Alexandre, Sebastian, KristianRunsRuns night shift 10.04 + morning shift 11.04These are the measurement runs of the night
shift (10/11.04.).
  
  202   Sun Apr 10 15:29:53 2022 RodolfoLaserStatus - Laser systemWe have checked the laser system.

- The pump laser has ~ 23Mio shots. The total
  
  201   Sun Apr 10 15:29:37 2022 Carsten,SarperAcceleratorEcooler failedEcooler failed @15:23 Carsten is fixing it
Fixed @16:00
  
  200   Sun Apr 10 15:16:19 2022 Carsten, Rodolfo, SarperRunsRuns afternoon shifts 10.04These are the measurement runs of the afternoon
shift (10.04.).
  
  199   Sun Apr 10 15:08:42 2022 CarstenDAQBackup of Data from 1rst Scanrange to extrenal RAID1 HDDsI just performed a backup of all data (+log-Files)
that were collected until now to the two
RAID HDDs.
  
  198   Sun Apr 10 13:17:53 2022 Kristian, MaxDAQWavemeter readoutWe changed the Labview code in order to reduce
the amount of data that was overfilling the
WM data queue. We removed the temperature
  
  197   Sun Apr 10 11:11:18 2022 Kristian, MaxLaseradditional WM readoutsince the WM readout still does not work reliably,
I started a python script at atppc023 that
saves timestamp and wavemeter frequency.
  
  196   Sun Apr 10 08:53:26 2022 Kristian, MaxLaserTiming verifiedtiming is still good.

we checked the relative timing between laser
  
  195   Sun Apr 10 06:39:16 2022 Kristian, Marek, MaxRunsruns morning shift 10.04.These are the measurement runs of the morning
shift (10.04.).
  
  194   Sun Apr 10 06:34:49 2022 Kristian, MaxDAQWavemeter ReadoutProblem solved. Ignore this entry

  
  193   Sun Apr 10 04:37:29 2022 PatrickDAQNext wavelength rangeMeasurements with the next wavelength scan
range should be started roughly around 12:00
noon. The plan is to go to lower wavelengths
 2022-04-10_calculations_323nm.jpg 
  192   Sun Apr 10 04:07:53 2022 PatrickDAQgo4 shows wrong frequencies and wavelengths[B]Update (ID:194):[/B] In labview "Stop All",
close labview, stop python script (ID:197),
close wavemeter. Then restart wavemeter,
 2022-04-10_measured_wavel.png2022-04-10_measured_wavel2.png2022-04-10_measured_wavel_go4.png 
  191   Sun Apr 10 03:56:56 2022 V. HannenDetectorsLow rate in PMT SouthPMT south shows a much lower count rate than
observed in elog entry 170.
 2022-04-10_PMTs_over_wavel-03_56.png 
  190   Sun Apr 10 02:20:17 2022 PatrickDAQNew mbs startup guideConnecting to the rfio server and opening
a file is included in '@startup' now. Since
mbs crashes reliably every 3 or 4 runs, it
  
  189   Sat Apr 9 19:50:40 2022 Carsten New thresholds for ADC of DAQ2 (starting with file0117)unsigned short caen_V785AH_threshold_mod0
[32] = 
                {0x0100 , 0x0004 , 0x0003
  
  188   Sat Apr 9 19:09:57 2022 RodolfoLaserOptimization - Resonator of dye laser I have tuned a bit the resonator of the dye
laser. 
  
  186   Sat Apr 9 16:55:19 2022 RodolfoLaser 16:15 I have changed the dye (of both oscillator
and amplifier).
  
  185   Sat Apr 9 15:47:21 2022 Carsten, Rodolfo, Sarper, PatrickRunsAfternoon and night shift runsAfter the morning shift, we got new increment
(nm) for the laser scanning. We are now scanning
2 nm of wavelength range in 5 big steps (5
  
  184   Sat Apr 9 14:15:44 2022 Kristian, Max, KonstantinDAQChange in LV codeWe changed the LV code so that the Cobra Set
Wavelength is permanently sent. Before it
was only sent once at the beginning of each
  
  183   Sat Apr 9 13:45:42 2022 Max, KristianRunsfirst scans with LV problem solved!This is the first time with LV buffer problem
solved (see Elog ID: 184). Before the PMT
signals were out of sync with the wavelength
  
  182   Sat Apr 9 06:42:23 2022 KristianLaserLaser step sizeWe changed the laser step size to 0.002 nm
which corresponds to 5.75 GHz.
  
  181   Sat Apr 9 06:25:22 2022 Max, KristianRunsmorning shift runsDAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
  
  180   Sat Apr 9 05:26:25 2022 PatrickLaserWavemeterThe wavemeter still shows large spikes from
time to time. The exposure time is still
at 34ms.
 2022-04-09_Wavemeter_during_scan5.png 
  179   Sat Apr 9 05:00:11 2022 CarstenGeneralDraft Docs and cheat sheetPlease check the attached files,

and correct or enhance them.
 e142_daq2_cabling.odsDocumentation_for_beamtime_2022_.doc 
  178   Sat Apr 9 04:40:01 2022 PatrickDAQBugged Trending plots?The problem from yesterday (ID:147) still
persists. All the plots (not only the labview
stuff) comes in too late in go4. However,
 2022-04-09_Cobra_set_wavelength2.png 
  177   Sat Apr 9 04:01:35 2022 Carsten 2nd DAQSwitched the CAEN TDC back on and changed
the threshoolds for the ADC to: 
  
  176   Sat Apr 9 03:57:10 2022 CarstenAcceleratorNew Cooler voltage after the crash of the coolerAfter the restart of the cooler the Ohmlabs
divider showed a voltage 16V lower than before.
This could also be seen as a slight shift
  
  175   Sat Apr 9 03:46:31 2022 CarstenAcceleratorSlits in TE lineChanged GTEDSAH Rechts to 10mm   
  174   Sat Apr 9 03:27:47 2022 PatrickDAQLaser scanningDAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
 does_not_write_data_to_file.png 
  173   Sat Apr 9 02:55:38 2022 CarstenAcceleratorKühlerausfall und Gründe dazuWir hatten heute Abend eine Kühlerausfall,
der uns mehrere Stunden beschäftigt hat,
weil  gem. Anzeige in Device Control kein
  
  172   Fri Apr 8 23:56:07 2022 PatrickDAQDAQ improvementAs requested in ID:146 and ID:147, the laserscan
tab was improved:
[LIST]
  
  171   Fri Apr 8 22:26:44 2022 PatrickDAQSpike in all detectorsIn the previous shift, there was a spike in
all detectors in the same scan step. Apparently,
this was NOT a resonance since in the next
  
  170   Fri Apr 8 17:57:45 2022 KonstantinDAQLaser scanning

[TABLE border="1"]
 Artifacts_in_PMT_MiddleAndNorth.png 
  169   Fri Apr 8 17:44:25 2022 KonstantinCalibrationFinal TimingWe measured the timing for the laser bunch
synchronization. A summary is given below.
  
  168   Fri Apr 8 15:45:24 2022 YL Spectrum manipulation 5See attached  IMG_3027.JPG 
  167   Fri Apr 8 15:42:20 2022 YuriAcceleratorSlits in the TE lineAt around 15:00, The slits in the TE line
were changed to :
TE4DS5HL -12 mm -> -20 mm
  
  166   Fri Apr 8 15:39:36 2022 allRunsfirst data after timing set upstarted taking data again

started at 15:40  
  
  165   Fri Apr 8 14:46:02 2022 Danyal & Sebastian & Volker & KenDetectorshigh dark countrate Cu PMT solvedThe problem - "discovered" by Volker and Ken
- of the high dark countrate of the Cu PMT
has been solved. 
 IMG_20220408_082804.jpgIMG_20220408_083031.jpg 
  164   Fri Apr 8 14:43:50 2022 WilfriedDAQlaser timing - Q-switch startbelow are my notes concerning laser timing
/ Q-switch start
 IMG_20220408_143753_resized_20220408_023840170.jpg 
  163   Fri Apr 8 14:14:28 2022 KristianDAQDelay of bunch RFThe bunch HF is now fed through a delay to
shift the stop trigger relative to the PMT
signal. The delay generator is placed directly
  
  162   Fri Apr 8 14:12:57 2022 morning shiftDAQtiming for h=1The timing for h=1 has been set up 

The time window is now twice as large as
 2022-04-08_timing_h1_final.png 
  161   Fri Apr 8 12:04:13 2022 RaganRunsNTCAP startedNTCAP is started for the data taking.

Carrier Frequency: 242.02 M
 IMG_0947.jpg 
  160   Fri Apr 8 11:16:57 2022 KristianLaserWavemeterWe changed the fiber to the wavemeter. The
third fiber worked best and we could operate
the WM at low exposure times, i.e., below
 Wavemeter.PNGWavemeter2.PNG 
  159   Fri Apr 8 11:02:04 2022 DW, YL, RSS, SL Change h=2 to h=1After changing to h=1
The frequency manipulation #5: f=242.021487MHz
(124th harmonic) [no bunching]
  
  158   Fri Apr 8 10:44:55 2022 Ragan, Yuri, Danyal, SergeyRunsNTCAP stoppedNTCAP is stopped. Sergey will now set an ion
bunch instead of two in the ESR.
  
  157   Fri Apr 8 09:39:04 2022 RaganRunsNTCAP startedCarrier Frequency: 242.2 M
IQ Rate (S/s): 10 M
Reference level (dBm): -30
  
  156   Fri Apr 8 09:33:52 2022 Dayshift 1 8.4.2022 Reference MeasurementsDAQ1: lxg1297:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
  
  155   Fri Apr 8 09:32:32 2022 RaganRunsNTCAP stoppedSince there is no beam, NTCAP is stopped.

Carrier Frequency: 242.2 M
  
  154   Fri Apr 8 09:13:38 2022 Ragan, DanyalAcceleratorNo beamCathode is being changed at the ion source.
So no beam for the moment.
  
  153   Fri Apr 8 08:40:06 2022 SebastianDAQDAQ improvementConcerning ID 146 a new histogram for accumulating
data (no cleaning histograms) can be found
under
  
  152   Fri Apr 8 08:17:52 2022 SebastianLaserLaser Ext Trig is workingWe (Max, Kristian, Danyal, me) fixed the "external
trigger" problem.
 upperDualTimerSettings.JPGlowerDualTimerSettings.JPGLampSyncToQSwitchTrig.JPGTriggerPulseTrain.JPG 
  151   Fri Apr 8 06:53:29 2022 RaganRunsNTCAP data takingNTCAP is taking data since 07.04.2022 23:53:47

Carrier Frequency: 242.2 M
 IMG_0936.jpg 
  150   Fri Apr 8 05:46:35 2022 V. HannenDetectorsHigh background rate in Cu PMT points to light leak in ESR or active pressure gaugeThe background rate of the Cu mirror PMT is
only about 300 cps when the mirror is in
the parking position but ca. 7000 cps when
  
  149   Fri Apr 8 03:54:39 2022 PatrickLaserQ-switch windowThe solution of increasing the Q-switch window
from 2us to 5us described in [I]ID:148[/I]
fulfills its purpose, but the window is unstable.
 2022-04-08_Q-switch_window.jpg 
  148   Fri Apr 8 02:14:05 2022 WilfriedLaserLaser timings adjusted Since we use the middle window as a reference
for the laser pulse timing, the fact that
the window is 2.25 m behind the target has
  
  147   Fri Apr 8 01:48:57 2022 PatrickDAQBugged Trending plots?The wavelengths/frequencies shown in the graph
in the labview window do not match the wavelengths/frequencies
in go4.
 2022-04-08_Cobra_set_wavelength.png 
  146   Fri Apr 8 01:18:51 2022 Ken UeberholzDAQTODO: DAQ improvements For somebody who knows the DAQ1 code: Go4
resets the histograms with each laser step.
Can there be additional histograms where
  
  145   Fri Apr 8 00:06:37 2022 PatrickLaserConnection to the laser pcTo login to the laser pc use the command

xfreerdp -g 1920x1080 -u atplaser atppc023.campus.gsi.de
  
  144   Thu Apr 7 22:18:06 2022 Night shift 7.4-8.4 Next scansDAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
  
  143   Thu Apr 7 19:13:26 2022 Konstantin, PatrickCalibrationHow to find the correct laser positionIn order to achieve the correct laser ion
beam superposition one needs to do the following
steps:
  
  142   Thu Apr 7 16:50:22 2022 KonstantinCalibrationSpacial laser-ion overlapLaser-ion-beam overlap was achieved after
measuring the ion beam positions (compare
[URL=https://elog.gsi.de/esr/E142/83]Entry
  
  141   Thu Apr 7 16:45:10 2022  DetectorsDetector distancesRelativ distances of the detector   20220407_164345.jpg 
  140   Thu Apr 7 15:18:25 2022 Danyal & SebastianDAQDAQ channelsWe checked again the cables for both DAQs

(on Carsten's kind request) 
  
  139   Thu Apr 7 14:13:27 2022 DanyalDetectorsnew PMT southI have replaced the PMT south (looks at the
gas target). 
in the hope that this will produce less dark
  
  138   Thu Apr 7 14:04:36 2022 Paul IndelicatoGeneralno beam until 17:0010:10  There is a problem with the UNILAC.

The repair will take several hours. (4 hrs?)
  
  137   Thu Apr 7 14:01:22 2022 Sebastian, MaxDetectorsMesytec resetThe Mesytec crate was turned off and on again.

It is again possible to communicate with
  
  136   Thu Apr 7 11:11:31 2022 Max, SebastianLaserdye changed, pulse energy measurementsWe changed the dye at 10am.

We increased the pump power for the dye Laser
  
  135   Thu Apr 7 10:10:31 2022 Ragan, Yuri, DanyalAcceleratorProblem in UNILACThe power supply of the UNILAC magnet is broken.
The repair will take up to 6-7 hours.
  
  134   Thu Apr 7 09:58:55 2022 Ragan, Yuri, DanyalAcceleratorKicker problem solvedThe kicker problem is solved and the beam
is back in the ESR.
  
  133   Thu Apr 7 09:23:18 2022 SebastianDAQDAQ1 & DAQ2 - 1kHz and delayed cs removedQuestionable 1kHz and delayed common stop
signals has been removed.
  
  132   Thu Apr 7 08:43:19 2022 Danyal, Yuri, RaganAcceleratoragain no injection in ESR - ESR kicker problemwe had no injections in the ESR again 

it turned out that the injection kicker of
  
  131   Thu Apr 7 08:14:03 2022 Yuri & DanyalGeneral229Th89+ line in Schottky GLOBAL calculations for the "content" of the
Th line in the Schottky spectrum
(380 MeV/u exit energy, equilibrium charge
  
  130   Thu Apr 7 07:40:09 2022 Danyal, Max, SebastianDAQNo beam and DAQs crashedsince shortly after 7 AM we have no beam in
the ESR
(reason unclear) 
  
  129   Thu Apr 7 05:55:17 2022 Ken UeberholzDetectorsXUV-Detector Mesytec crashWhen the XUV-detector has to shut down unexpectedly,
it can happen that the Mesytek power supply
crashes and can't be 
  
  128   Thu Apr 7 05:44:40 2022 Pierre-Michel, RaganDAQNTCAP settingsCarrier Frequency: 244M
IQ Rate: 10M
reference Level: -30
  
  127   Thu Apr 7 05:23:50 2022 PatrickDAQHow To Start MBS for DAQ2 (Carstens DAQ)(MBS server should be running at the LXG0155
machine. If not you will get an error message.
Then start the server - last command in console)
  
  126   Thu Apr 7 04:48:58 2022   ToDo's for 07.04.Some ToDo's for the next shift:
- Work on  Laser stabilisation 2nd stage
in the ESR
  
  125   Thu Apr 7 04:10:18 2022 Ken UeberholzDAQCorrected cabling DAQ 2A lot of cables were wrongly or not 
connected to the DAQ 2. 
 20220407_043337.jpg 
  124   Thu Apr 7 03:44:21 2022 PatrickDAQMeasurement procedure[U][B]Measurement procedure[/B][/U]

  
  123   Thu Apr 7 03:09:36 2022 CarstenDAQNTCAP running since 02:40    
  122   Thu Apr 7 03:06:15 2022 PatrickDAQDAQ file sizesThe file sizes of DAQ1 (229Thor) and DAQ2
(229Th, "Carstens DAQ") are different.
During 20min of laser scanning DAQ1 saves
  
  121   Thu Apr 7 02:32:29 2022 all on shiftRunsFirst Scans 322-320nmLaser scanning from 322-320 steps 0.01nm/s
DAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
  
  120   Thu Apr 7 01:19:05 2022 PatrickLaserLaser scanningWe did some laser scans. The wavemeter shows
spikes during scans. This may be just while
the frequency changes. See picture.
 2022-04-07_Wavemeter_during_scan.png2022-04-07_Wavemeter_during_scan2.png2022-04-07_Wavemeter_during_scan3.png2022-04-07_Wavemeter_during_scan4.png 
  119   Thu Apr 7 00:36:36 2022 UweDAQThreshholds and shaping Mesytec for ADC   snapshot3.png 
  118   Thu Apr 7 00:15:11 2022 PatrickLaserLaser timing adjustedWe have adjusted the laser timing using PMT-middle.
Bunching freq. is 3.90362 MHz.
 220407-Laser-ion-timing.png220407-Laser-ion-timing-full-period.png220407-ParDetSO_PMT-middle.png 
  117   Wed Apr 6 22:29:55 2022 PatrickAcceleratorECooler voltagesECooler voltages:

[B]06.04:[/B]
  
  116   Wed Apr 6 21:03:25 2022 Ken Ueberholz DetectorsXuv-Detektor, further information Some further information regarding the 
xuv-detector and its components.
 xuv_detektor.pdf 
  115   Wed Apr 6 19:39:08 2022 Ken Ueberholz DetectorsLED installed The UV-LED of Münster was connected over 
channel 8 to the Messhütte. 6V are 
supplied by the power supply (picture 2).
 20220406_193541.jpg20220406_193439.jpg 
  113   Wed Apr 6 18:51:33 2022 Danyal & CarstenAcceleratortarget bumpThis afternoon, we found out that Sergey has
also implemented a "target bump". 
Although we do not use a target, this bump
  
  112   Wed Apr 6 16:01:07 2022 BLAcceleratorESR settings before adjusting laser: 2022-04-06_14-37-30_ESR_EXP22_02_238U92_Brandau_30March22.C1.txt # Version: 1.2
# Comment: ParamModi Export at 2022-04-06T14:37:35.957978+02:00[Europe/Berlin]
# Context: ESR_EXP22_02_238U92_Brandau_30March22.C1
  
  111   Wed Apr 6 15:19:29 2022 Svea, ShahabAccelerator5s delay implemented before injectionOperators have informed us that for better
stability and operation (and cooperation
with HHT), and after discussing with Sergey,
  
  110   Wed Apr 6 14:52:29 2022 RodolfoRunsScraping the ion beamWe are T-scraping the ion beam.    
  108   Wed Apr 6 13:32:57 2022 Max, SebastianDAQLabView Cobra Channel Listchannel 0: linux time (epoch time)
channel 1: ms timer
channel 2: E-Cooler Voltage(Ohmlabs)
  
  107   Wed Apr 6 09:30:53 2022 DanyalAcceleratorESR is blue again - errors are fixedThe ESR is "blue" again. 

The errors (scu related) have been fixed.
  
  106   Wed Apr 6 08:31:54 2022 Danyal & ReginaGeneralESR had some errorsRegina noticed that the ESR was "red" 

This means that there are some errors. 
  
  105   Wed Apr 6 08:06:02 2022 DanyalDAQstopped NTCAP data acquisitionI stopped the NTCAP data acquisition at 8
AM.
  
  104   Tue Apr 5 23:55:11 2022 CarstenRunsLong time measurment with NTCAPSettings:
Center: 2242.5MHz
RefLevel: -25dB
  
  103   Tue Apr 5 23:07:34 2022 CarstenAccelerator229Th89+ identification after re-tuning of the ESRThe ESR was retuned this aftenoon since the
it was unclear if we still sit the 229Th89+
line.
  
  102   Tue Apr 5 20:58:53 2022 WilfriedLaserTrigger for LaserElectronic for the timing of the laser puls
optimized. The problem with the broad photodiode
histograms is solved.
 TriggerForLaser_05-04-2022.PNGTriggerLaser_Cabling.jpg 
  101   Tue Apr 5 20:16:13 2022 RodolfoLaserDiscriminator for HF reference signalFor the laser trigger we need to generate
a few ns NIM-puls from the HF reference signal.
Therefore we (Wilfried, Konstantin and me)
 CFD_für_HFSignal.jpgDisc_HFSignal_05-04-2022.PNG 
  100   Tue Apr 5 15:25:47 2022 Sebastian, Kristian, Pierre-MichelDAQGo4 Conditions for "TDC_stacked_Sig/Ref" histogramFirst version of TDC_stacked histograms implemented.

Under folder "Conditions" you can now integrate
  
  99   Tue Apr 5 14:51:51 2022 KristianDAQdark countsWe shielded the PMTs, i.e., the N2 tube, which
improved the Cu PMT background rate.
  
  98   Tue Apr 5 13:28:06 2022 KristianDAQSpikes in PMT signalOccasionally, we noticed a spike in the PMT
signal. No ions in the ring and at PMT Cu
was not even supplied with HV. Has to be
 spike.png 
  97   Tue Apr 5 13:24:40 2022 KristianDetectorsPMT CuHV cable was in wrong channel in power supply.
Now it is back to the correct position. Checked
connection at the PMT.
  
  96   Tue Apr 5 12:17:12 2022 Ragan, Rui-JiuDAQInstructions to start and stop NTCAPAttached are the instructions to start and
stop data taking using the NTCAP.
 Start_data_taking.pdfStop_data_taking.pdfStart_data_taking.pngStop_data_taking.png 
  95   Tue Apr 5 11:14:52 2022 Sebastian, Kristian, Pierre-MichelDAQPMT over wavelength histogram v2Today we finalized the PMT over wavelength
histogram in:
  
  94   Tue Apr 5 09:45:47 2022 Danyal & YuriAcceleratorbeam is back in the ESR - a slit was moved inAnd now also in English :) 

The ion beam is back in the ESR! 
  
  93   Tue Apr 5 09:39:01 2022 Danyal & YuriAcceleratorStrahl ist wieder im ESR - Schlitz war reingefahrenDer Strahl ist wieder im ESR! 
Angeblich war einen Schlitz, oder sogar 2,
reingefahren worden. 
  
  92   Tue Apr 5 08:00:50 2022 Kristian & SebastianDAQMBS Channellist (so far)MBS Channellist (time 5.4.2022)

0 Anode
  
  91   Mon Apr 4 19:05:57 2022 CarstenDAQCooler Frequency Signals Ion current not connected until nowUp to now the signals for 
Ion Current
Cooler elctron current
  
  90   Mon Apr 4 17:26:48 2022 Jan GloriusDAQMSCF shaper settingsattached are the current shaper settings.

list of currently connected channels:
 setting_e142.start3 
  89   Mon Apr 4 16:26:04 2022 CarstenDAQBackup Harddisk /External DiskSince we cannot write on lustre, as a temproal
solution two RAID 1 (mirror) USB hard disks
 with cpacity 6 TB each are installed.
  
  88   Mon Apr 4 15:32:38 2022 Kristiand & SebastianDAQGo4 Backup CodeDue to some code changes (PMT over wavelength
historgram) Kristian and I backuped a working
Go4 code in the current go4 folder on the
  
  87   Mon Apr 4 15:27:31 2022 SebastianDAQPMT over wavelength histogramKristian and I tried to create a "PMT over
wavelength" histogram under step2Anl/LabView.
Unfortunately, the code ist still in progress
  
  86   Mon Apr 4 09:10:44 2022 Ragan, Yuri, Rui-JiuRunsMeasurementNTCAP is taking data with the beam with a
stop at manipulation 5 (taking all the fragments).
  
  85   Mon Apr 4 00:19:16 2022 Ken UeberholzDAQFirstTestsNew measurement:
Start: About 00:12
Stop: About 00:43
 44_AM.png06_AM.png 
  83   Sun Apr 3 18:52:30 2022 KonstantinCalibrationLaser ion beam overlapWe measured vertical and horizontal ion beam
positions. Unfortunately, the horizontal
scraper positions can not be manipulated
  
  82   Sun Apr 3 18:41:11 2022 Konstantin and RodolfoLaserBeam Position StabilizationWe (Konstantin and I) have optimized the TEM
"laser-beam position stabilization".
 MRC_Konfiguration_MitMainAmp_03-04-2022.pngMRC-ControllerSetting_03-04-2022.jpgFG_SettingsMRC_03-04-2022.jpgTriggerSignals_f_MRC_04-04-2022.PNG 
  81   Sun Apr 3 15:34:34 2022 Ken Ueberholz  Xuv-Detektor CFD-treshholdI co controlled all detector signals and 
adjusted the threshold to be just above 
the noise. I will double check this when
  
  80   Sun Apr 3 13:05:08 2022 CarstenLaserDistance of Partilce detecotrs wr.t. to electron coolerAs of Yuris post in the elog the positions
(Info from H. Weick):
  
  79   Sun Apr 3 12:35:17 2022 MaxDAQGo 4 manualHow to start go4?:

- go to console
 go4_1.pnggo4_2.pnggo4_3.png 
  78   Sun Apr 3 12:31:10 2022 Rui-Jiu Chen, Yuri, Carsten, RaganRunsMeasurement of beam with different circlesParameters of NTCAP:

  1. IQ rate 20 MSamples/s
 6x 
  77   Sun Apr 3 11:40:48 2022 Shahab, YuriDetectors245 MHz Resonator tuned to new frequencyresonance frequency changed from 243.2 MHz
to 244.692 MHz by reducing the value of both
of the plungers from 395 to 325. Now after
 Screenshot_2022-04-03_at_11.24.15.png 
  76   Sun Apr 3 11:01:57 2022 RodolfoAcceleratorScrapers @ E-CoolerWe the mid- and night shift (Wilfried, Simon,
Patrick, Ken and me) we not able to manipulate
the scrapers in the E-Cooler.
  
  75   Sun Apr 3 10:35:20 2022 Yuri (Sergey)AcceleratorDipole correctionThe ramp for moving the beam to the central
orbit
To be inserted into manipulation, GE01MU1
  
  74   Sun Apr 3 10:28:25 2022 Yuri (Helmut Weick)AcceleratorDistance cooler - detectorCalculation from Helmut Weick
Distance e-cooler to particle detectors chamber:
“This is half of ESR plus distance target
  
  73   Sun Apr 3 00:41:45 2022 Ken Ueberholz  Xuv-Detektor Signale The Xuv-detector cabel channels seem to be

wrongly labeled in the Messhütte (see 
 20220403_004944.jpg 
  72   Sat Apr 2 23:16:55 2022 Carsten Cu mirror and CsI moved in and out of the ringKen tested the Cu-mirror and CsI disk Detector.
They move without a problem and don't scrape
the ion beam.
  
  71   Sat Apr 2 22:43:36 2022 Carsten Ring set-up for 229/89+, scraped and bunched, Iel=500mA at injection and 100mA during measurmentThe ring SIS/ESR were set up for 229/89+.
Pölease note that this not only 1e- Th but
ponteially also the isobars of Ac (0e-1)/Pa(2e-,
  
  70   Sat Apr 2 18:28:47 2022 Markus/BerndAccelerator SIS setting complete for fragments in ESR: 2022-04-02_18-09-10_SIS18_FAST_E142_20220325_110213.C1.txt # Version: 1.2 # Comment: ParamModi Export
at 2022-04-02T18:09:36.402593+02:00[Europe/Berlin]
# Context: SIS18_FAST_E142_20220325_110213.C1
  
  69   Sat Apr 2 18:19:47 2022 YuriAcceleratorScraping   trim.3539D818-8003-4093-866E-2C4F619E614F.MOV 
  68   Sat Apr 2 18:17:31 2022 YuriAcceleratorPhoto-IdentificationJust a photo of the ID  9FFA52AA-1F75-470E-AD1B-E1A612A3F7D6.jpeg 
  67   Sat Apr 2 17:47:16 2022 Ken Ueberholz  Telefon, GästehausMy guesthouse phone number: 06159-71-2957   
  66   Sat Apr 2 16:10:22 2022 Markus, BerndAcceleratorSIS setting complete, U90+ mit Be target: 2022-04-02_16-04-00_SIS18_FAST_E142_20220325_110213.C1.txt # Version: 1.2
# Comment: ParamModi Export at 2022-04-02T16:04:10.778077+02:00[Europe/Berlin]
# Context: SIS18_FAST_E142_20220325_110213.C1
  
  65   Sat Apr 2 15:54:32 2022 CarstenAcceleratorESR setup with primary beam and 1cm Be plate + Schottky data on NTCAPMArkus and Bernd have setup the ESR with the
thick stripper foil and put the ion beam
(238U92+) on the central orbit.
  
  64   Sat Apr 2 10:22:21 2022 Rui-Jiu Chen, RaganGeneralBeam is in the ESRPrimary beam is in the ESR now. Markus and
the team are tuning the ESR.
  
  63   Sat Apr 2 05:08:00 2022 KristianGeneralMorning shiftI see no updates in the log. Is the morning
shift taking place?
  
  62   Sat Apr 2 01:27:25 2022 Jan GloriusRunstest runs 02.04.2022Beam settings:
primary beam 
copper stripper
 setting_e142.1648855568 
  Draft   Sat Apr 2 01:02:39 2022 Carsten Test measurements with two DAQsWe do two measurements:

One measurement using the 
  
  60   Fri Apr 1 23:47:45 2022 CarstenDetectorsPMT thresholds / PMT north does not allow voltage abow ~ -1kVChecked thresholds of PMT with beam and without
beam.
  
  59   Fri Apr 1 23:12:37 2022 PatrickDetectorsScraper positions "only primary beam"
Scraper positions where there is only primary
beam for detector tests. Use only one outer
  
  58   Fri Apr 1 22:01:14 2022 KonstantinDetectorsPMT operating voltages> During the testing of the PMTs the following
operating voltages were applied:
  
  57   Fri Apr 1 18:30:38 2022 CarstenDetectorsPositions / Voltages threshlds for particle detectors[B]DC beam 238U92+ (205kV, e-beam)[/B]
We used the detector NA_SZ to determine the
central primary-beam (238U92+) position by
  
  56   Fri Apr 1 18:19:58 2022 KristianCalibrationHV dividerWe checked the strange behavior of the HV
dividers again. The Ohmlabs and the PTB divider
are in good agreement at 120 kV and 150 kV.
  
  55   Fri Apr 1 16:46:33 2022 CarstenDetectorsAll pressuzied air drives are tested now and are working properlyAll pressuzied air drives are tested now and
are working properly
  
  54   Fri Apr 1 15:52:23 2022 RodolfoDetectorsUV PMT SouthThe "Solar Blind PMT" labeled as "PMT South"
has been installed by Simon and Max in the
gas target chamber on a CaF Viewport. The
 PMT_Sued_Target.jpg 
  53   Fri Apr 1 15:27:00 2022 RodolfoDetectorsNitrogen for UV-PMTsThere was a question concerning the nitrogen
we use to rinse the "Solar Blind PMTs".
 Stickstoff_f_PMTs.jpgStickstoff_Flussrate.jpg 
  52   Fri Apr 1 11:19:57 2022 Rui-Jiu ChenDAQS.M.A.R.T check on NTCAPS.M.A.R.T. check has been done on NTCAP on
March 28th. All 12 hard disk drivers  are
normal.
 image001(04-01-11-10-06).jpg 
  51   Fri Apr 1 11:00:41 2022 Rui-Jiu ChenDAQStart NTCAPStart taking data with NTCAP.
Carrier Frequency: 245MHz
IQ rate:5 MSamples/s
  
  50   Fri Apr 1 02:29:40 2022 Carsten ESR Cooler crashedESR cooler crashed. We could not restart the
cooler. Since we had several other problems,
we stop now.
  
  49   Fri Apr 1 01:57:12 2022 KristianDAQTimingwith bunched primary beam (bunching frequency
1.94070 MHz) we have strong PMT (mid) and
particle detector signal. Time between both
 Particle-PMT_Mid.pngPMT-PD.pngIMG_20220331_235846.jpg 
  47   Fri Apr 1 00:27:27 2022 Carsten Settings Particle Detectors /Tests with primary beamAll the beam settings will be given in a separate
post.
  
  46   Thu Mar 31 22:41:35 2022 KristianCalibrationHV dividerWe noticed a difference in the electron cooler
high voltage:
 HV-divider2.png 
  45   Thu Mar 31 22:19:14 2022 KristianDAQHow To Start MBS(MBS server should be running at the LXG1297
machine. If not you will get an error message.
Then start the server - last command in console)
  
  44   Thu Mar 31 20:07:47 2022 ShahabDAQSchottky Display in AP Messhütte (or anywhere else)[B]UPDATE: 16.05.2022[/B]

[I]Please use ATPPC029 instead of ATPPC019
 04_PM_schottky.png 
  43   Thu Mar 31 17:56:32 2022 KonstantinDAQPhotodiode test signalWe used a signal generator to provide a 4MHz
dummy-RF signal. This was divided by a factor
of 2 for laser-"bunch" synchronization and
 Timing_Photodiodes.png 
  42   Thu Mar 31 15:53:50 2022 KonstantinDetectorsControl software for XUV and copper mirror detector> Attached you find a manual for the software
used to control the movement of the XUV detector
and the copper mirror detector. 
 XUV_Cu_GUI.png 
  41   Thu Mar 31 13:28:17 2022 Jan GloriusDAQDAQ-2 cabling docunewest version V2 - valid since Mo 04.April
2022
 e142_daq2_cabling.pdfe142_daq2_cabling_V2.pdfe142_daq2_cabling_V2.ods 
  40   Thu Mar 31 11:49:54 2022 KonstantinDetectorsHV-Supply of particle detectors We cross-checked the cabeling of the particle
detectors north and south. Particle detector
south is connected to channel [B]HV5[/B]
  
  39   Wed Mar 30 09:27:15 2022 RodolfoAcceleratorIssue? Scrapers at E-CoolerCarsten* forwarded me an E-Mail from Markus
yesterday. "Betreff: Scraper im ESR Elektronenkühler"
 Schrittmotorsteuerung_ECooler.JPG 
  38   Tue Mar 29 21:37:13 2022 RodolfoLaserPump LaserThe gold "reflectors and end plates" of our
pump laser (Quanta-Ray PRO) have been exchanged
by new ones.
 QRay_GoldReflektoren_2010-2022.jpg 
  37   Tue Mar 29 12:47:26 2022 Ken Ueberholz Parameter setting for XUV and copper mirror detector Some Default Settings for the XUV 
Detector. The copper 
mirror should always move fully in.
  
  36   Tue Mar 29 12:01:08 2022 RodolfoLaserLaser targetsI have installed two targets* (size: 2 inches)
to monitor the position of the laser beam.
 TargetIN_SO.pngTargetOUT_NO.pngTargetControlBox.jpg 
  35   Fri Mar 25 14:31:24 2022 RodolfoLaserPhotodiode signal SO in the MesshütteMeasured at the Panel "Messhütte - Laserhütte",
BNC "Fast PD / SO".
 PD_SO_Signal_MH_25-03-2022.PNG 
  34   Thu Mar 24 17:10:33 2022 CarstenDAQDAQ / MBS VUPROM TDC buffer errorsVUPROM TDC buffer errors potentially due to
long TDC common Stop gate (>1ms from div
200).
  
  33   Thu Mar 24 16:59:35 2022 RodolfoLaserPhotodiode signal SOFast Photodiode signal at the "SO-Bogen" (South-east
arc).
 FastPD_SO_Signal_24-03-2022.jpgFastPD_SO_24-03-2022.jpg 
  32   Thu Mar 24 13:27:47 2022 RodolfoDAQDisk space - LXG1297In our Linux computer (LXG1297: Laser spectroscopy)
we have a Drive with 1.8 TB total disk space.
300 GB are at the moment in use, but I can
 DiskSpace_lxg1297.JPG 
  31   Wed Mar 23 16:58:33 2022 V. HannenDetectorsStatus copper mirror and XUV detectorsOver the past days, the parabolic copper mirror
and XUV detectors haven been prepared and
tested for the upcoming beamtime (see first
 det-overview.jpglaserlab-crate.jpgtrigger-module.jpg 
  30   Wed Mar 23 16:16:42 2022 V. HannenDetectorsControl software for XUV and copper mirror detectorAttached you find a manual for the software
used to control the movement of the XUV detector
and the copper mirror detector. 
 Manual.pdf 
  29   Wed Mar 23 15:38:15 2022 CarstenGeneralNot all lights in the ESR can be switched offThree of the lights in the ESR cannot be switched
off. It seems that these lights are now "emergency
lights" (with battery?). We will need to
  
  28   Wed Mar 23 11:20:55 2022 SimonDetectorsPMT operating voltagesDuring the testing of the PMTs the following
operating voltages were applied:
  
  27   Mon Mar 21 21:48:46 2022 JanDAQMesyTec Shaper ControlThe MesyTec Shaper & Constant Fraction (MSCF)
is used to process the PMT/det signals for
the ADC in the second DAQ.
  
  26   Mon Mar 21 17:03:47 2022  DAQChanging code of go4Correction: Comments in C/C++ start with //
, i.e. forward slash
  
  25   Mon Mar 21 16:33:23 2022  DAQChanging code of go4We agreed to indicate changes in the go4 analysis
code according to the
following scheme
  
  24   Mon Mar 21 10:46:18 2022 RodolfoDAQTDC & Scaler description channelsFor the First Vuprom we have the following
channel configuration (Stand:21.03.2021).
 Screenshot_TLdaInputDescription_21-03-2022.JPG 
  23   Mon Mar 21 09:18:28 2022 RodolfoAcceleratorPressure at North-East Arc Our vacuum expert has reply. The "IZ Pump"
in this region was off.
  
  22   Fri Mar 18 16:58:26 2022 RodolfoAcceleratorPressure at North-East Arc The pressure at the north-east arc of ESR,
where the laser window is located, looks
suspicious. The sensor E01LF02 shows a value
 Druck_E01LF02_18-03-2022.jpgDruck_E01LF02_07-02-2022.jpg 
  21   Fri Mar 18 16:51:27 2022 CarstenDAQMain DAQ /MBS errorMBS error "TDC data ready wait" solved. Common
stop trigger (20 kHz) was missing. (according
to Sebastian)
  
  20   Fri Mar 18 09:18:38 2022 RodolfoAcceleratorVacuum leak, ODRAfter the beaking out process we got a vacuum
leak in one of the MgF2 windows (Referenz:
PMT South) of the optical detection region
 MgF2-Window_VACSeal.jpg 
  19   Thu Mar 17 17:56:33 2022 KristianCalibrationHV dividersPTB HV dividers arrived. Divider ratios are:

PT120:          12003,341 
 Bericht_PTB_verbesserter_Teiler_2018.pdf 
  18   Thu Mar 17 17:37:49 2022 RodolfoAcceleratorHigh voltage dividers for E-CoolerTwo dividers, from PTB-Braunschweig, have
been deliver today. We will use them to monitor
the electron-cooler voltage in situ.
 PTB_Spannungsteiler_Mar2022.jpg 
  17   Wed Mar 16 12:04:40 2022 KristianDetectorsHV cable to particle detector SouthChecked HV cable to particle detector south.
Label is HV2 Scraper. 
  
  16   Wed Mar 16 08:31:52 2022 KristianDAQCheck cables and timingKonstantin and I generated a signal in the
Messhütte and sent it to the ESR. 
There, we used a 44m BNC cable that was sufficently
  
  15   Thu Mar 10 15:20:26 2022 Jan DAQanalog branch signal patches to Messhütte The additional signals from PMTs and XUV detector
needed for spectroscopic analysis in the
second DAQ are patched to AP Messhütte (MH)
 red_panel_ESR.jpgpulser_signal_ESR.jpgpulser_signal_MH.jpgdelay_ESR-MH-ESR.jpgcable_bundle_mirror_chamber.jpg 
  14   Thu Mar 3 21:39:21 2022 RodolfoLaserDye solution, DCM in Ethanol and DMSOI have prepared a new dye solution of DCM
in Ethanol and DMSO (1:1). The concentration
of the "oscillator + preamplifier" is 0,3
 FarbstoffVorrat_Thorium.jpg 
  13   Thu Mar 3 17:34:42 2022 RodolfoLaserPump Laser We have issues with our Pump Laser (Spectra
Physics - Quanta Ray Pro). After the service
made on mid Dezember (2021) the laser does
 QRAY_Simmern.jpg 
  12   Thu Mar 3 17:21:26 2022 RodolfoDetectorsMgF2 WindowsNew reentrance viewports made of MgF2 have
been installed at the ESR "Optical Detection
Region". In the middle the old window (also
 ESR_Schaufenster_Spiegelkammer_10-02-2022.jpg 
  11   Thu Mar 3 13:50:45 2022 RodolfoLaserDye cell cracketThe "20 mm" dye cell used for the Oscillator
and Pramplifier got damage. I supposed it
was produced by the pump beam hitting on
 Cobra_Farbstoffzelle_08-02-2022.jpg 
  10   Fri Nov 19 15:50:44 2021 RodolfoAcceleratorLaser windows at E-Cooler sideNew laser viewports have been installed at
the E-Cooler side of the ESR.
 ESR_Laserfenster_NO_Nov2021.jpgESR_Laserfenster_SO_Nov2021.jpg 
  9   Fri Nov 5 17:23:23 2021 RodolfoDAQDye trigger out The dye laser offers different scan settings
(see pages 65 - 67 of the user manual). We
are using the following setting, see attached
 Cobra_ScanSettings_05-11-2021.PNG 
  8   Thu Oct 14 10:21:46 2021 RodolfoDetectorsDismounting Cu-MirrorWe have dismounted the parabolic Cu-Mirror
at ESR on 13.10.2021 
 AusbauCuSpiegel_2021.jpg 
  Draft   Wed Sep 8 21:44:55 2021 RodolfoGeneralPreparation[TABLE border="1"]
[B]Status[/B]|[B]Arbeitspaket[/B]|[COLOR=chocolate][B]Kommentare[/B][/COLOR]
|-
  
  6   Fri Aug 6 10:40:54 2021 RodolfoDAQmbs in atplaserThe "MBS program" (data acquisition) is now
located within atplaser@r4l-41, in the folder
"th21":
  
  5   Fri Aug 6 10:23:00 2021 RodolfoDAQatplaser on r4l-41The user [B]atplaser[/B] is now existing on
the [B]R4L-XY[/B] nodes for the ESR group.
  
  4   Mon Aug 2 10:54:44 2021 RodolfoLaserQuanta Ray - Water leak in the power supplyAfter fixing the broken water connector in
the laser head a new water leak appeared
in the Quanta-Ray power supply. 
 QRAY_WaterPump.jpg 
  3   Wed Jul 28 13:31:22 2021 RodolfoGeneralAir filtersFilters (Hepa-) inside the flow boxes have
been replaced.
 Flowbox_Filters.png 
  2   Mon Jul 26 17:58:52 2021 RodolfoLaserWater FiltersThe water filters (deioninzing and particle)
have been replaced. 
 QRAY_DeionizingFilter.jpg 
  1   Mon Jul 26 17:15:47 2021 RodolfoLaserQuanta Ray - Water leakOn Thursday afternoon (22.07.2021) a water
connector has broken and water has been spilled
in the laser head. 
 QRAY_AnschlussGeplatzt.jpg 